Benefits of Integrated RIS/PACS/Reporting Due to Automatic Population of Templated Reports

With integration of the Radiological Information Systems (RIS), Picture Archiving and Communication systems (PACS), and reporting systems, patient identifiers and examination information can automatically map into examination reports. There are many potential benefits of report automation to radiolo...

Full description

Saved in:
Bibliographic Details
Published in:Current problems in diagnostic radiology 2019-01, Vol.48 (1), p.37-39
Main Authors: Kovacs, Mark D., Cho, Maximilian Y., Burchett, Philip F., Trambert, Michael
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c368t-cf45bdaf61c95bfd649084565b96ef4f352978089922d2af9c4b936a4e41a4a73
cites cdi_FETCH-LOGICAL-c368t-cf45bdaf61c95bfd649084565b96ef4f352978089922d2af9c4b936a4e41a4a73
container_end_page 39
container_issue 1
container_start_page 37
container_title Current problems in diagnostic radiology
container_volume 48
creator Kovacs, Mark D.
Cho, Maximilian Y.
Burchett, Philip F.
Trambert, Michael
description With integration of the Radiological Information Systems (RIS), Picture Archiving and Communication systems (PACS), and reporting systems, patient identifiers and examination information can automatically map into examination reports. There are many potential benefits of report automation to radiologists including improvements in efficiency, accuracy, and fatigue. In this article we describe a 2 part study, with the first part being an anonymous survey of radiologists concerning report automation. A total of 13 staff radiologists and 9 radiology residents at a single institution completed an anonymous survey. Respondents were asked if automatic population of examination description, comparison examination data, indications, computed tomography dose, technique, and copy to physician data saved time, decreased fatigue, and increased accuracy. Respondents were asked if a “copy findings” function saved time. The second objective part of the study was a mock examination experiment to assess time savings of report automation and to assess error rates. Of all, 9 radiologists were asked to dictate fields for 8 mock examinations. Subjects were timed and reporting errors monitored. Estimated daily time savings and error rates were calculated assuming a mix of 80 studies. A total of 95% surveyed responded that report automation saved time; 91% that report automation improved accuracy of dictations; 82% that report automation decreased fatigue. Furthermore, 83% of copy finding function users reported time savings. Average time to dictate these prepopulated fields was 51 seconds per study. Average error rate per report was 0.86, with an average of 0.26 errors remaining uncorrected upon report completion. Estimated average time per day saved per radiologist from report automation was 68 minutes. Estimated average corrected errors was 48 per day. Estimated average uncorrected or missed errors was 21 per day. These estimated benefits from report automation result from tight integration of RIS, PACS, and reporting systems.
doi_str_mv 10.1067/j.cpradiol.2017.12.002
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1994359188</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0363018817302050</els_id><sourcerecordid>1994359188</sourcerecordid><originalsourceid>FETCH-LOGICAL-c368t-cf45bdaf61c95bfd649084565b96ef4f352978089922d2af9c4b936a4e41a4a73</originalsourceid><addsrcrecordid>eNqFkD1v2zAQhomiQewm-QuBxi6S-SVK3Oo6aWsgQIPYWbIQFHU0aEiiSlIF-u8j10nXTnfD-9yLexC6JbggWFSrY2HGoFvnu4JiUhWEFhjTD2hJSlbmgmH6ES0xEyzHpK4X6FOMR4wJlaS6RAsqmayokEv08hUGsC7FzNtsOyQ4BJ2gzZ62u9XjerNbPcHoQ3LDIbubIEs-W0_J9zo5kz36cermzQ8neA_92J3Zv0i8RhdWdxFu3uYVev52v9_8yB9-ft9u1g-5YaJOubG8bFptBTGybGwruMQ1L0XZSAGWW1ZSWdW4lpLSlmorDW8kE5oDJ5rril2hz-e7Y_C_JohJ9S4a6Do9gJ-iIlJyVspZwxwV56gJPsYAVo3B9Tr8UQSrk1d1VO9e1cmrIlTNXmfw9q1janpo_2HvIufAl3MA5k9_OwgqGgeDgdYFMEm13v2v4xXrzYyA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1994359188</pqid></control><display><type>article</type><title>Benefits of Integrated RIS/PACS/Reporting Due to Automatic Population of Templated Reports</title><source>Elsevier</source><creator>Kovacs, Mark D. ; Cho, Maximilian Y. ; Burchett, Philip F. ; Trambert, Michael</creator><creatorcontrib>Kovacs, Mark D. ; Cho, Maximilian Y. ; Burchett, Philip F. ; Trambert, Michael</creatorcontrib><description>With integration of the Radiological Information Systems (RIS), Picture Archiving and Communication systems (PACS), and reporting systems, patient identifiers and examination information can automatically map into examination reports. There are many potential benefits of report automation to radiologists including improvements in efficiency, accuracy, and fatigue. In this article we describe a 2 part study, with the first part being an anonymous survey of radiologists concerning report automation. A total of 13 staff radiologists and 9 radiology residents at a single institution completed an anonymous survey. Respondents were asked if automatic population of examination description, comparison examination data, indications, computed tomography dose, technique, and copy to physician data saved time, decreased fatigue, and increased accuracy. Respondents were asked if a “copy findings” function saved time. The second objective part of the study was a mock examination experiment to assess time savings of report automation and to assess error rates. Of all, 9 radiologists were asked to dictate fields for 8 mock examinations. Subjects were timed and reporting errors monitored. Estimated daily time savings and error rates were calculated assuming a mix of 80 studies. A total of 95% surveyed responded that report automation saved time; 91% that report automation improved accuracy of dictations; 82% that report automation decreased fatigue. Furthermore, 83% of copy finding function users reported time savings. Average time to dictate these prepopulated fields was 51 seconds per study. Average error rate per report was 0.86, with an average of 0.26 errors remaining uncorrected upon report completion. Estimated average time per day saved per radiologist from report automation was 68 minutes. Estimated average corrected errors was 48 per day. Estimated average uncorrected or missed errors was 21 per day. These estimated benefits from report automation result from tight integration of RIS, PACS, and reporting systems.</description><identifier>ISSN: 0363-0188</identifier><identifier>EISSN: 1535-6302</identifier><identifier>DOI: 10.1067/j.cpradiol.2017.12.002</identifier><identifier>PMID: 29397269</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Attitude to Computers ; Automation ; Efficiency, Organizational - statistics &amp; numerical data ; Humans ; Radiologists - psychology ; Radiology Information Systems - statistics &amp; numerical data ; Surveys and Questionnaires ; Time Factors ; Tomography, X-Ray Computed</subject><ispartof>Current problems in diagnostic radiology, 2019-01, Vol.48 (1), p.37-39</ispartof><rights>2019 Elsevier Inc.</rights><rights>Copyright © 2019 Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c368t-cf45bdaf61c95bfd649084565b96ef4f352978089922d2af9c4b936a4e41a4a73</citedby><cites>FETCH-LOGICAL-c368t-cf45bdaf61c95bfd649084565b96ef4f352978089922d2af9c4b936a4e41a4a73</cites><orcidid>0000-0003-3746-3554</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29397269$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kovacs, Mark D.</creatorcontrib><creatorcontrib>Cho, Maximilian Y.</creatorcontrib><creatorcontrib>Burchett, Philip F.</creatorcontrib><creatorcontrib>Trambert, Michael</creatorcontrib><title>Benefits of Integrated RIS/PACS/Reporting Due to Automatic Population of Templated Reports</title><title>Current problems in diagnostic radiology</title><addtitle>Curr Probl Diagn Radiol</addtitle><description>With integration of the Radiological Information Systems (RIS), Picture Archiving and Communication systems (PACS), and reporting systems, patient identifiers and examination information can automatically map into examination reports. There are many potential benefits of report automation to radiologists including improvements in efficiency, accuracy, and fatigue. In this article we describe a 2 part study, with the first part being an anonymous survey of radiologists concerning report automation. A total of 13 staff radiologists and 9 radiology residents at a single institution completed an anonymous survey. Respondents were asked if automatic population of examination description, comparison examination data, indications, computed tomography dose, technique, and copy to physician data saved time, decreased fatigue, and increased accuracy. Respondents were asked if a “copy findings” function saved time. The second objective part of the study was a mock examination experiment to assess time savings of report automation and to assess error rates. Of all, 9 radiologists were asked to dictate fields for 8 mock examinations. Subjects were timed and reporting errors monitored. Estimated daily time savings and error rates were calculated assuming a mix of 80 studies. A total of 95% surveyed responded that report automation saved time; 91% that report automation improved accuracy of dictations; 82% that report automation decreased fatigue. Furthermore, 83% of copy finding function users reported time savings. Average time to dictate these prepopulated fields was 51 seconds per study. Average error rate per report was 0.86, with an average of 0.26 errors remaining uncorrected upon report completion. Estimated average time per day saved per radiologist from report automation was 68 minutes. Estimated average corrected errors was 48 per day. Estimated average uncorrected or missed errors was 21 per day. These estimated benefits from report automation result from tight integration of RIS, PACS, and reporting systems.</description><subject>Attitude to Computers</subject><subject>Automation</subject><subject>Efficiency, Organizational - statistics &amp; numerical data</subject><subject>Humans</subject><subject>Radiologists - psychology</subject><subject>Radiology Information Systems - statistics &amp; numerical data</subject><subject>Surveys and Questionnaires</subject><subject>Time Factors</subject><subject>Tomography, X-Ray Computed</subject><issn>0363-0188</issn><issn>1535-6302</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNqFkD1v2zAQhomiQewm-QuBxi6S-SVK3Oo6aWsgQIPYWbIQFHU0aEiiSlIF-u8j10nXTnfD-9yLexC6JbggWFSrY2HGoFvnu4JiUhWEFhjTD2hJSlbmgmH6ES0xEyzHpK4X6FOMR4wJlaS6RAsqmayokEv08hUGsC7FzNtsOyQ4BJ2gzZ62u9XjerNbPcHoQ3LDIbubIEs-W0_J9zo5kz36cermzQ8neA_92J3Zv0i8RhdWdxFu3uYVev52v9_8yB9-ft9u1g-5YaJOubG8bFptBTGybGwruMQ1L0XZSAGWW1ZSWdW4lpLSlmorDW8kE5oDJ5rril2hz-e7Y_C_JohJ9S4a6Do9gJ-iIlJyVspZwxwV56gJPsYAVo3B9Tr8UQSrk1d1VO9e1cmrIlTNXmfw9q1janpo_2HvIufAl3MA5k9_OwgqGgeDgdYFMEm13v2v4xXrzYyA</recordid><startdate>201901</startdate><enddate>201901</enddate><creator>Kovacs, Mark D.</creator><creator>Cho, Maximilian Y.</creator><creator>Burchett, Philip F.</creator><creator>Trambert, Michael</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-3746-3554</orcidid></search><sort><creationdate>201901</creationdate><title>Benefits of Integrated RIS/PACS/Reporting Due to Automatic Population of Templated Reports</title><author>Kovacs, Mark D. ; Cho, Maximilian Y. ; Burchett, Philip F. ; Trambert, Michael</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c368t-cf45bdaf61c95bfd649084565b96ef4f352978089922d2af9c4b936a4e41a4a73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Attitude to Computers</topic><topic>Automation</topic><topic>Efficiency, Organizational - statistics &amp; numerical data</topic><topic>Humans</topic><topic>Radiologists - psychology</topic><topic>Radiology Information Systems - statistics &amp; numerical data</topic><topic>Surveys and Questionnaires</topic><topic>Time Factors</topic><topic>Tomography, X-Ray Computed</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kovacs, Mark D.</creatorcontrib><creatorcontrib>Cho, Maximilian Y.</creatorcontrib><creatorcontrib>Burchett, Philip F.</creatorcontrib><creatorcontrib>Trambert, Michael</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Current problems in diagnostic radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kovacs, Mark D.</au><au>Cho, Maximilian Y.</au><au>Burchett, Philip F.</au><au>Trambert, Michael</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Benefits of Integrated RIS/PACS/Reporting Due to Automatic Population of Templated Reports</atitle><jtitle>Current problems in diagnostic radiology</jtitle><addtitle>Curr Probl Diagn Radiol</addtitle><date>2019-01</date><risdate>2019</risdate><volume>48</volume><issue>1</issue><spage>37</spage><epage>39</epage><pages>37-39</pages><issn>0363-0188</issn><eissn>1535-6302</eissn><abstract>With integration of the Radiological Information Systems (RIS), Picture Archiving and Communication systems (PACS), and reporting systems, patient identifiers and examination information can automatically map into examination reports. There are many potential benefits of report automation to radiologists including improvements in efficiency, accuracy, and fatigue. In this article we describe a 2 part study, with the first part being an anonymous survey of radiologists concerning report automation. A total of 13 staff radiologists and 9 radiology residents at a single institution completed an anonymous survey. Respondents were asked if automatic population of examination description, comparison examination data, indications, computed tomography dose, technique, and copy to physician data saved time, decreased fatigue, and increased accuracy. Respondents were asked if a “copy findings” function saved time. The second objective part of the study was a mock examination experiment to assess time savings of report automation and to assess error rates. Of all, 9 radiologists were asked to dictate fields for 8 mock examinations. Subjects were timed and reporting errors monitored. Estimated daily time savings and error rates were calculated assuming a mix of 80 studies. A total of 95% surveyed responded that report automation saved time; 91% that report automation improved accuracy of dictations; 82% that report automation decreased fatigue. Furthermore, 83% of copy finding function users reported time savings. Average time to dictate these prepopulated fields was 51 seconds per study. Average error rate per report was 0.86, with an average of 0.26 errors remaining uncorrected upon report completion. Estimated average time per day saved per radiologist from report automation was 68 minutes. Estimated average corrected errors was 48 per day. Estimated average uncorrected or missed errors was 21 per day. These estimated benefits from report automation result from tight integration of RIS, PACS, and reporting systems.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>29397269</pmid><doi>10.1067/j.cpradiol.2017.12.002</doi><tpages>3</tpages><orcidid>https://orcid.org/0000-0003-3746-3554</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0363-0188
ispartof Current problems in diagnostic radiology, 2019-01, Vol.48 (1), p.37-39
issn 0363-0188
1535-6302
language eng
recordid cdi_proquest_miscellaneous_1994359188
source Elsevier
subjects Attitude to Computers
Automation
Efficiency, Organizational - statistics & numerical data
Humans
Radiologists - psychology
Radiology Information Systems - statistics & numerical data
Surveys and Questionnaires
Time Factors
Tomography, X-Ray Computed
title Benefits of Integrated RIS/PACS/Reporting Due to Automatic Population of Templated Reports
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T01%3A51%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Benefits%20of%20Integrated%20RIS/PACS/Reporting%20Due%20to%20Automatic%20Population%20of%20Templated%20Reports&rft.jtitle=Current%20problems%20in%20diagnostic%20radiology&rft.au=Kovacs,%20Mark%20D.&rft.date=2019-01&rft.volume=48&rft.issue=1&rft.spage=37&rft.epage=39&rft.pages=37-39&rft.issn=0363-0188&rft.eissn=1535-6302&rft_id=info:doi/10.1067/j.cpradiol.2017.12.002&rft_dat=%3Cproquest_cross%3E1994359188%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c368t-cf45bdaf61c95bfd649084565b96ef4f352978089922d2af9c4b936a4e41a4a73%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1994359188&rft_id=info:pmid/29397269&rfr_iscdi=true