Loading…
Influence of suture size on the frictional performance of surgical suture evaluated by a penetration friction measurement approach
The frictional performances of surgical sutures have been found to play a vital role in their functionality. The purpose of this paper is to understand the frictional performance of multifilament surgical sutures interacting with skin substitute, by means of a penetration friction apparatus (PFA). T...
Saved in:
Published in: | Journal of the mechanical behavior of biomedical materials 2018-04, Vol.80, p.171-179 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c404t-b85d979f544176685ab52f1308014b3a296ac91cd30161b38946210380e13b7d3 |
---|---|
cites | cdi_FETCH-LOGICAL-c404t-b85d979f544176685ab52f1308014b3a296ac91cd30161b38946210380e13b7d3 |
container_end_page | 179 |
container_issue | |
container_start_page | 171 |
container_title | Journal of the mechanical behavior of biomedical materials |
container_volume | 80 |
creator | Zhang, Gangqiang Zeng, Xiangqiong Su, Yibo Borras, F.X. de Rooij, Matthijn B. Ren, Tianhui van der Heide, Emile |
description | The frictional performances of surgical sutures have been found to play a vital role in their functionality. The purpose of this paper is to understand the frictional performance of multifilament surgical sutures interacting with skin substitute, by means of a penetration friction apparatus (PFA). The influence of the size of the surgical suture was investigated. The relationship between the friction force and normal force was considered, in order to evaluate the friction performance of a surgical suture penetrating a skin substitute. The friction force was measured by PFA. The normal force applied to the surgical suture was estimated based on a Hertzian contact model, a finite element model (FEM), and a uniaxial deformation model (UDM).
The results indicated that the penetration friction force increased as the size of the multifilament surgical suture increased. In addition, when the normal force was predicted by UDM, it was found that the ratio between the friction force and normal force decreased as the normal force increased. A comparison of the results suggested that the UDM was appropriate in predicting the frictional behavior of surgical suturing.
[Display omitted]
•Influence of surgical suture sizes on the frictional performance is investigated.•Normal force applied to the surgical suture is estimated by three different models.•Relationship between friction force and normal force is considered.•New penetration friction apparatus (PFA) for surgical suture is used. |
doi_str_mv | 10.1016/j.jmbbm.2018.02.003 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2001072284</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1751616118300730</els_id><sourcerecordid>2001072284</sourcerecordid><originalsourceid>FETCH-LOGICAL-c404t-b85d979f544176685ab52f1308014b3a296ac91cd30161b38946210380e13b7d3</originalsourceid><addsrcrecordid>eNp9kD1vFDEQhi0EIsnBL0BCLml2M2Pvh7egQFEgkSKlgdqyvbPEp_04bG-kpOSXx8ddrqSyPXreeeWHsU8IJQI2l9tyO1k7lQJQlSBKAPmGnaNqVZEn8Dbf2xqLBhs8YxcxbgEaAKXeszPRVaLtpDxnf2_nYVxpdsSXgcc1rYF49M_5OfP0QHwI3iW_zGbkOwrDEiZzgsNv7_L8mKJHM64mUc_tEzeZnikFs8-elvCJTI7RRHPiZrcLi3EPH9i7wYyRPh7PDfv1_frn1U1xd__j9urbXeEqqFJhVd13bTfUVYVt06ja2FoMKEEBVlYa0TXGdeh6meWglaqrGoEgFRBK2_Zyw74c9ubaPyvFpCcfHY2jmWlZoxYACK0QqsqoPKAuLDEGGvQu-MmEJ42g9_L1Vv-Tr_fyNQid5efU52PBaifqT5lX2xn4egAof_PRU9DR-b373gdySfeL_2_BC8vdl_s</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2001072284</pqid></control><display><type>article</type><title>Influence of suture size on the frictional performance of surgical suture evaluated by a penetration friction measurement approach</title><source>Elsevier</source><creator>Zhang, Gangqiang ; Zeng, Xiangqiong ; Su, Yibo ; Borras, F.X. ; de Rooij, Matthijn B. ; Ren, Tianhui ; van der Heide, Emile</creator><creatorcontrib>Zhang, Gangqiang ; Zeng, Xiangqiong ; Su, Yibo ; Borras, F.X. ; de Rooij, Matthijn B. ; Ren, Tianhui ; van der Heide, Emile</creatorcontrib><description>The frictional performances of surgical sutures have been found to play a vital role in their functionality. The purpose of this paper is to understand the frictional performance of multifilament surgical sutures interacting with skin substitute, by means of a penetration friction apparatus (PFA). The influence of the size of the surgical suture was investigated. The relationship between the friction force and normal force was considered, in order to evaluate the friction performance of a surgical suture penetrating a skin substitute. The friction force was measured by PFA. The normal force applied to the surgical suture was estimated based on a Hertzian contact model, a finite element model (FEM), and a uniaxial deformation model (UDM).
The results indicated that the penetration friction force increased as the size of the multifilament surgical suture increased. In addition, when the normal force was predicted by UDM, it was found that the ratio between the friction force and normal force decreased as the normal force increased. A comparison of the results suggested that the UDM was appropriate in predicting the frictional behavior of surgical suturing.
[Display omitted]
•Influence of surgical suture sizes on the frictional performance is investigated.•Normal force applied to the surgical suture is estimated by three different models.•Relationship between friction force and normal force is considered.•New penetration friction apparatus (PFA) for surgical suture is used.</description><identifier>ISSN: 1751-6161</identifier><identifier>EISSN: 1878-0180</identifier><identifier>DOI: 10.1016/j.jmbbm.2018.02.003</identifier><identifier>PMID: 29427933</identifier><language>eng</language><publisher>Netherlands: Elsevier Ltd</publisher><subject>Normal force ; Penetration contact model ; Penetration friction ; Skin substitute ; Surgical suture</subject><ispartof>Journal of the mechanical behavior of biomedical materials, 2018-04, Vol.80, p.171-179</ispartof><rights>2018 Elsevier Ltd</rights><rights>Copyright © 2018 Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c404t-b85d979f544176685ab52f1308014b3a296ac91cd30161b38946210380e13b7d3</citedby><cites>FETCH-LOGICAL-c404t-b85d979f544176685ab52f1308014b3a296ac91cd30161b38946210380e13b7d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29427933$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zhang, Gangqiang</creatorcontrib><creatorcontrib>Zeng, Xiangqiong</creatorcontrib><creatorcontrib>Su, Yibo</creatorcontrib><creatorcontrib>Borras, F.X.</creatorcontrib><creatorcontrib>de Rooij, Matthijn B.</creatorcontrib><creatorcontrib>Ren, Tianhui</creatorcontrib><creatorcontrib>van der Heide, Emile</creatorcontrib><title>Influence of suture size on the frictional performance of surgical suture evaluated by a penetration friction measurement approach</title><title>Journal of the mechanical behavior of biomedical materials</title><addtitle>J Mech Behav Biomed Mater</addtitle><description>The frictional performances of surgical sutures have been found to play a vital role in their functionality. The purpose of this paper is to understand the frictional performance of multifilament surgical sutures interacting with skin substitute, by means of a penetration friction apparatus (PFA). The influence of the size of the surgical suture was investigated. The relationship between the friction force and normal force was considered, in order to evaluate the friction performance of a surgical suture penetrating a skin substitute. The friction force was measured by PFA. The normal force applied to the surgical suture was estimated based on a Hertzian contact model, a finite element model (FEM), and a uniaxial deformation model (UDM).
The results indicated that the penetration friction force increased as the size of the multifilament surgical suture increased. In addition, when the normal force was predicted by UDM, it was found that the ratio between the friction force and normal force decreased as the normal force increased. A comparison of the results suggested that the UDM was appropriate in predicting the frictional behavior of surgical suturing.
[Display omitted]
•Influence of surgical suture sizes on the frictional performance is investigated.•Normal force applied to the surgical suture is estimated by three different models.•Relationship between friction force and normal force is considered.•New penetration friction apparatus (PFA) for surgical suture is used.</description><subject>Normal force</subject><subject>Penetration contact model</subject><subject>Penetration friction</subject><subject>Skin substitute</subject><subject>Surgical suture</subject><issn>1751-6161</issn><issn>1878-0180</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp9kD1vFDEQhi0EIsnBL0BCLml2M2Pvh7egQFEgkSKlgdqyvbPEp_04bG-kpOSXx8ddrqSyPXreeeWHsU8IJQI2l9tyO1k7lQJQlSBKAPmGnaNqVZEn8Dbf2xqLBhs8YxcxbgEaAKXeszPRVaLtpDxnf2_nYVxpdsSXgcc1rYF49M_5OfP0QHwI3iW_zGbkOwrDEiZzgsNv7_L8mKJHM64mUc_tEzeZnikFs8-elvCJTI7RRHPiZrcLi3EPH9i7wYyRPh7PDfv1_frn1U1xd__j9urbXeEqqFJhVd13bTfUVYVt06ja2FoMKEEBVlYa0TXGdeh6meWglaqrGoEgFRBK2_Zyw74c9ubaPyvFpCcfHY2jmWlZoxYACK0QqsqoPKAuLDEGGvQu-MmEJ42g9_L1Vv-Tr_fyNQid5efU52PBaifqT5lX2xn4egAof_PRU9DR-b373gdySfeL_2_BC8vdl_s</recordid><startdate>201804</startdate><enddate>201804</enddate><creator>Zhang, Gangqiang</creator><creator>Zeng, Xiangqiong</creator><creator>Su, Yibo</creator><creator>Borras, F.X.</creator><creator>de Rooij, Matthijn B.</creator><creator>Ren, Tianhui</creator><creator>van der Heide, Emile</creator><general>Elsevier Ltd</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201804</creationdate><title>Influence of suture size on the frictional performance of surgical suture evaluated by a penetration friction measurement approach</title><author>Zhang, Gangqiang ; Zeng, Xiangqiong ; Su, Yibo ; Borras, F.X. ; de Rooij, Matthijn B. ; Ren, Tianhui ; van der Heide, Emile</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c404t-b85d979f544176685ab52f1308014b3a296ac91cd30161b38946210380e13b7d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Normal force</topic><topic>Penetration contact model</topic><topic>Penetration friction</topic><topic>Skin substitute</topic><topic>Surgical suture</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zhang, Gangqiang</creatorcontrib><creatorcontrib>Zeng, Xiangqiong</creatorcontrib><creatorcontrib>Su, Yibo</creatorcontrib><creatorcontrib>Borras, F.X.</creatorcontrib><creatorcontrib>de Rooij, Matthijn B.</creatorcontrib><creatorcontrib>Ren, Tianhui</creatorcontrib><creatorcontrib>van der Heide, Emile</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of the mechanical behavior of biomedical materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zhang, Gangqiang</au><au>Zeng, Xiangqiong</au><au>Su, Yibo</au><au>Borras, F.X.</au><au>de Rooij, Matthijn B.</au><au>Ren, Tianhui</au><au>van der Heide, Emile</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Influence of suture size on the frictional performance of surgical suture evaluated by a penetration friction measurement approach</atitle><jtitle>Journal of the mechanical behavior of biomedical materials</jtitle><addtitle>J Mech Behav Biomed Mater</addtitle><date>2018-04</date><risdate>2018</risdate><volume>80</volume><spage>171</spage><epage>179</epage><pages>171-179</pages><issn>1751-6161</issn><eissn>1878-0180</eissn><abstract>The frictional performances of surgical sutures have been found to play a vital role in their functionality. The purpose of this paper is to understand the frictional performance of multifilament surgical sutures interacting with skin substitute, by means of a penetration friction apparatus (PFA). The influence of the size of the surgical suture was investigated. The relationship between the friction force and normal force was considered, in order to evaluate the friction performance of a surgical suture penetrating a skin substitute. The friction force was measured by PFA. The normal force applied to the surgical suture was estimated based on a Hertzian contact model, a finite element model (FEM), and a uniaxial deformation model (UDM).
The results indicated that the penetration friction force increased as the size of the multifilament surgical suture increased. In addition, when the normal force was predicted by UDM, it was found that the ratio between the friction force and normal force decreased as the normal force increased. A comparison of the results suggested that the UDM was appropriate in predicting the frictional behavior of surgical suturing.
[Display omitted]
•Influence of surgical suture sizes on the frictional performance is investigated.•Normal force applied to the surgical suture is estimated by three different models.•Relationship between friction force and normal force is considered.•New penetration friction apparatus (PFA) for surgical suture is used.</abstract><cop>Netherlands</cop><pub>Elsevier Ltd</pub><pmid>29427933</pmid><doi>10.1016/j.jmbbm.2018.02.003</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1751-6161 |
ispartof | Journal of the mechanical behavior of biomedical materials, 2018-04, Vol.80, p.171-179 |
issn | 1751-6161 1878-0180 |
language | eng |
recordid | cdi_proquest_miscellaneous_2001072284 |
source | Elsevier |
subjects | Normal force Penetration contact model Penetration friction Skin substitute Surgical suture |
title | Influence of suture size on the frictional performance of surgical suture evaluated by a penetration friction measurement approach |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T21%3A53%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Influence%20of%20suture%20size%20on%20the%20frictional%20performance%20of%20surgical%20suture%20evaluated%20by%20a%20penetration%20friction%20measurement%20approach&rft.jtitle=Journal%20of%20the%20mechanical%20behavior%20of%20biomedical%20materials&rft.au=Zhang,%20Gangqiang&rft.date=2018-04&rft.volume=80&rft.spage=171&rft.epage=179&rft.pages=171-179&rft.issn=1751-6161&rft.eissn=1878-0180&rft_id=info:doi/10.1016/j.jmbbm.2018.02.003&rft_dat=%3Cproquest_cross%3E2001072284%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c404t-b85d979f544176685ab52f1308014b3a296ac91cd30161b38946210380e13b7d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2001072284&rft_id=info:pmid/29427933&rfr_iscdi=true |