Preparation of ionic liquid based solid-phase microextraction fiber and its application to forensic determination of methamphetamine and amphetamine in human urine

A new solid-phase microextraction (SPME) procedure using an ionic liquid (IL) has been developed. Reusable IL-based SPME fiber was prepared for the first time by fixing IL through cross-linkage of IL impregnated silicone elastomer on the surface of a fused silica fiber. 1-Ethoxyethyl-3-methylimidazl...

Full description

Saved in:
Bibliographic Details
Published in:Journal of Chromatography A 2009-06, Vol.1216 (24), p.4824-4830
Main Authors: He, Yi, Pohl, Jeremy, Engel, Robert, Rothman, Leah, Thomas, Marie
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c511t-aa2d3970200b0160ac5467ef4a4e8a358c75bd0ae5c954bfff791422c31f9a163
cites cdi_FETCH-LOGICAL-c511t-aa2d3970200b0160ac5467ef4a4e8a358c75bd0ae5c954bfff791422c31f9a163
container_end_page 4830
container_issue 24
container_start_page 4824
container_title Journal of Chromatography A
container_volume 1216
creator He, Yi
Pohl, Jeremy
Engel, Robert
Rothman, Leah
Thomas, Marie
description A new solid-phase microextraction (SPME) procedure using an ionic liquid (IL) has been developed. Reusable IL-based SPME fiber was prepared for the first time by fixing IL through cross-linkage of IL impregnated silicone elastomer on the surface of a fused silica fiber. 1-Ethoxyethyl-3-methylimidazloium bis(trifluoromethane) sulfonylimide ([EeMim][NTf 2]) ionic liquid was employed as a demonstration and the prepared fiber was applied to the forensic headspace determination of methamphetamine (MAP) and amphetamine (AP) in human urine samples. Important extraction parameters including the concentration of salt and base in sample matrix, extraction temperature and extraction time were investigated and optimized. Combined with gas chromatography/mass spectrometry (GC/MS) working in selected ion monitoring (SIM) mode, the new method showed good linearity in the range of 20–1500 μg L −1, good repeatability (RSD < 7.5% for MAP, and
doi_str_mv 10.1016/j.chroma.2009.04.028
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_20085065</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0021967309005664</els_id><sourcerecordid>20085065</sourcerecordid><originalsourceid>FETCH-LOGICAL-c511t-aa2d3970200b0160ac5467ef4a4e8a358c75bd0ae5c954bfff791422c31f9a163</originalsourceid><addsrcrecordid>eNp9kc1u1TAQhbMAqaX0DZDwBnYJYztObjZIqOJPqgQSdG1NnDHxVRKntoPo8_Ci-DZVxaqr0bHO-Tw_RfGKQ8WBN--OlRmDn7ESAF0FdQXi8Kw4BxC87JpWnhUvYjwC8BZacV78_R5oxYDJ-YV5y3Jxhk3udnMD6zHSwKKf3FCuYxZsdiZ4-pMCmvuEdT0FhsvAXIoM13VyZmclz6wPtMSMGyhRmN3y-MtMacR5HSlhfqZ7wP_aLWzcZlzYFrJ8WTy3OEW6fKgXxc2njz-vvpTX3z5_vfpwXRrFeSoRxSC7FvLgfd4EoFF105KtsaYDSnUwreoHQFKmU3VvrW07XgthJLcd8kZeFG937hr87UYx6dlFQ9OEC_kt6gw-KGhUNta7MS8jxkBWr8HNGO40B326gj7q_QqnTKeh1vkKOfbmgY_R4GQDLsbFx6zgqpYdiOx7vfsseo2_Qvbc_BDAZSZLKdWp0_e7g_I6fjsKOhpHi6HBBTJJD9493co_LvKvKA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>20085065</pqid></control><display><type>article</type><title>Preparation of ionic liquid based solid-phase microextraction fiber and its application to forensic determination of methamphetamine and amphetamine in human urine</title><source>Elsevier</source><creator>He, Yi ; Pohl, Jeremy ; Engel, Robert ; Rothman, Leah ; Thomas, Marie</creator><creatorcontrib>He, Yi ; Pohl, Jeremy ; Engel, Robert ; Rothman, Leah ; Thomas, Marie</creatorcontrib><description>A new solid-phase microextraction (SPME) procedure using an ionic liquid (IL) has been developed. Reusable IL-based SPME fiber was prepared for the first time by fixing IL through cross-linkage of IL impregnated silicone elastomer on the surface of a fused silica fiber. 1-Ethoxyethyl-3-methylimidazloium bis(trifluoromethane) sulfonylimide ([EeMim][NTf 2]) ionic liquid was employed as a demonstration and the prepared fiber was applied to the forensic headspace determination of methamphetamine (MAP) and amphetamine (AP) in human urine samples. Important extraction parameters including the concentration of salt and base in sample matrix, extraction temperature and extraction time were investigated and optimized. Combined with gas chromatography/mass spectrometry (GC/MS) working in selected ion monitoring (SIM) mode, the new method showed good linearity in the range of 20–1500 μg L −1, good repeatability (RSD &lt; 7.5% for MAP, and &lt;11.5% for AP, n = 6), and low detection limits (0.1 μg L −1 for MAP and 0.5 μg L −1 for AP). Feasibility of the method was evaluated by analyzing human urine samples. Although IL-based SPME is still at the beginning of its development stage, the results obtained by this work showed that it is a promising simple, fast and sensitive sample preparation method.</description><identifier>ISSN: 0021-9673</identifier><identifier>DOI: 10.1016/j.chroma.2009.04.028</identifier><identifier>CODEN: JOCRAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Biological and medical sciences ; Drug addictions ; Ionic liquid ; Medical sciences ; Solid-phase microextraction (SPME) ; Toxicology</subject><ispartof>Journal of Chromatography A, 2009-06, Vol.1216 (24), p.4824-4830</ispartof><rights>2009 Elsevier B.V.</rights><rights>2009 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c511t-aa2d3970200b0160ac5467ef4a4e8a358c75bd0ae5c954bfff791422c31f9a163</citedby><cites>FETCH-LOGICAL-c511t-aa2d3970200b0160ac5467ef4a4e8a358c75bd0ae5c954bfff791422c31f9a163</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=21543902$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>He, Yi</creatorcontrib><creatorcontrib>Pohl, Jeremy</creatorcontrib><creatorcontrib>Engel, Robert</creatorcontrib><creatorcontrib>Rothman, Leah</creatorcontrib><creatorcontrib>Thomas, Marie</creatorcontrib><title>Preparation of ionic liquid based solid-phase microextraction fiber and its application to forensic determination of methamphetamine and amphetamine in human urine</title><title>Journal of Chromatography A</title><description>A new solid-phase microextraction (SPME) procedure using an ionic liquid (IL) has been developed. Reusable IL-based SPME fiber was prepared for the first time by fixing IL through cross-linkage of IL impregnated silicone elastomer on the surface of a fused silica fiber. 1-Ethoxyethyl-3-methylimidazloium bis(trifluoromethane) sulfonylimide ([EeMim][NTf 2]) ionic liquid was employed as a demonstration and the prepared fiber was applied to the forensic headspace determination of methamphetamine (MAP) and amphetamine (AP) in human urine samples. Important extraction parameters including the concentration of salt and base in sample matrix, extraction temperature and extraction time were investigated and optimized. Combined with gas chromatography/mass spectrometry (GC/MS) working in selected ion monitoring (SIM) mode, the new method showed good linearity in the range of 20–1500 μg L −1, good repeatability (RSD &lt; 7.5% for MAP, and &lt;11.5% for AP, n = 6), and low detection limits (0.1 μg L −1 for MAP and 0.5 μg L −1 for AP). Feasibility of the method was evaluated by analyzing human urine samples. Although IL-based SPME is still at the beginning of its development stage, the results obtained by this work showed that it is a promising simple, fast and sensitive sample preparation method.</description><subject>Biological and medical sciences</subject><subject>Drug addictions</subject><subject>Ionic liquid</subject><subject>Medical sciences</subject><subject>Solid-phase microextraction (SPME)</subject><subject>Toxicology</subject><issn>0021-9673</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNp9kc1u1TAQhbMAqaX0DZDwBnYJYztObjZIqOJPqgQSdG1NnDHxVRKntoPo8_Ci-DZVxaqr0bHO-Tw_RfGKQ8WBN--OlRmDn7ESAF0FdQXi8Kw4BxC87JpWnhUvYjwC8BZacV78_R5oxYDJ-YV5y3Jxhk3udnMD6zHSwKKf3FCuYxZsdiZ4-pMCmvuEdT0FhsvAXIoM13VyZmclz6wPtMSMGyhRmN3y-MtMacR5HSlhfqZ7wP_aLWzcZlzYFrJ8WTy3OEW6fKgXxc2njz-vvpTX3z5_vfpwXRrFeSoRxSC7FvLgfd4EoFF105KtsaYDSnUwreoHQFKmU3VvrW07XgthJLcd8kZeFG937hr87UYx6dlFQ9OEC_kt6gw-KGhUNta7MS8jxkBWr8HNGO40B326gj7q_QqnTKeh1vkKOfbmgY_R4GQDLsbFx6zgqpYdiOx7vfsseo2_Qvbc_BDAZSZLKdWp0_e7g_I6fjsKOhpHi6HBBTJJD9493co_LvKvKA</recordid><startdate>20090612</startdate><enddate>20090612</enddate><creator>He, Yi</creator><creator>Pohl, Jeremy</creator><creator>Engel, Robert</creator><creator>Rothman, Leah</creator><creator>Thomas, Marie</creator><general>Elsevier B.V</general><general>Amsterdam; New York: Elsevier</general><general>Elsevier</general><scope>FBQ</scope><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QH</scope><scope>7U7</scope><scope>7UA</scope><scope>C1K</scope><scope>F1W</scope><scope>H97</scope><scope>L.G</scope></search><sort><creationdate>20090612</creationdate><title>Preparation of ionic liquid based solid-phase microextraction fiber and its application to forensic determination of methamphetamine and amphetamine in human urine</title><author>He, Yi ; Pohl, Jeremy ; Engel, Robert ; Rothman, Leah ; Thomas, Marie</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c511t-aa2d3970200b0160ac5467ef4a4e8a358c75bd0ae5c954bfff791422c31f9a163</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Biological and medical sciences</topic><topic>Drug addictions</topic><topic>Ionic liquid</topic><topic>Medical sciences</topic><topic>Solid-phase microextraction (SPME)</topic><topic>Toxicology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>He, Yi</creatorcontrib><creatorcontrib>Pohl, Jeremy</creatorcontrib><creatorcontrib>Engel, Robert</creatorcontrib><creatorcontrib>Rothman, Leah</creatorcontrib><creatorcontrib>Thomas, Marie</creatorcontrib><collection>AGRIS</collection><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Aqualine</collection><collection>Toxicology Abstracts</collection><collection>Water Resources Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) 3: Aquatic Pollution &amp; Environmental Quality</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) Professional</collection><jtitle>Journal of Chromatography A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>He, Yi</au><au>Pohl, Jeremy</au><au>Engel, Robert</au><au>Rothman, Leah</au><au>Thomas, Marie</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Preparation of ionic liquid based solid-phase microextraction fiber and its application to forensic determination of methamphetamine and amphetamine in human urine</atitle><jtitle>Journal of Chromatography A</jtitle><date>2009-06-12</date><risdate>2009</risdate><volume>1216</volume><issue>24</issue><spage>4824</spage><epage>4830</epage><pages>4824-4830</pages><issn>0021-9673</issn><coden>JOCRAM</coden><abstract>A new solid-phase microextraction (SPME) procedure using an ionic liquid (IL) has been developed. Reusable IL-based SPME fiber was prepared for the first time by fixing IL through cross-linkage of IL impregnated silicone elastomer on the surface of a fused silica fiber. 1-Ethoxyethyl-3-methylimidazloium bis(trifluoromethane) sulfonylimide ([EeMim][NTf 2]) ionic liquid was employed as a demonstration and the prepared fiber was applied to the forensic headspace determination of methamphetamine (MAP) and amphetamine (AP) in human urine samples. Important extraction parameters including the concentration of salt and base in sample matrix, extraction temperature and extraction time were investigated and optimized. Combined with gas chromatography/mass spectrometry (GC/MS) working in selected ion monitoring (SIM) mode, the new method showed good linearity in the range of 20–1500 μg L −1, good repeatability (RSD &lt; 7.5% for MAP, and &lt;11.5% for AP, n = 6), and low detection limits (0.1 μg L −1 for MAP and 0.5 μg L −1 for AP). Feasibility of the method was evaluated by analyzing human urine samples. Although IL-based SPME is still at the beginning of its development stage, the results obtained by this work showed that it is a promising simple, fast and sensitive sample preparation method.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><doi>10.1016/j.chroma.2009.04.028</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0021-9673
ispartof Journal of Chromatography A, 2009-06, Vol.1216 (24), p.4824-4830
issn 0021-9673
language eng
recordid cdi_proquest_miscellaneous_20085065
source Elsevier
subjects Biological and medical sciences
Drug addictions
Ionic liquid
Medical sciences
Solid-phase microextraction (SPME)
Toxicology
title Preparation of ionic liquid based solid-phase microextraction fiber and its application to forensic determination of methamphetamine and amphetamine in human urine
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-04T16%3A46%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Preparation%20of%20ionic%20liquid%20based%20solid-phase%20microextraction%20fiber%20and%20its%20application%20to%20forensic%20determination%20of%20methamphetamine%20and%20amphetamine%20in%20human%20urine&rft.jtitle=Journal%20of%20Chromatography%20A&rft.au=He,%20Yi&rft.date=2009-06-12&rft.volume=1216&rft.issue=24&rft.spage=4824&rft.epage=4830&rft.pages=4824-4830&rft.issn=0021-9673&rft.coden=JOCRAM&rft_id=info:doi/10.1016/j.chroma.2009.04.028&rft_dat=%3Cproquest_cross%3E20085065%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c511t-aa2d3970200b0160ac5467ef4a4e8a358c75bd0ae5c954bfff791422c31f9a163%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=20085065&rft_id=info:pmid/&rfr_iscdi=true