Fixed, object-specific intensity compensation for cone beam optical CT radiation dosimetry

Optical cone beam computed tomography (CT) scanning of radiochromic gel dosimeters, using a CCD camera and a low stray light convergent source, provides fast, truly 3D radiation dosimetry with high accuracy. However, a key limiting factor in radiochromic gel dosimetry at large ( 10 cm diameter) volu...

Full description

Saved in:
Bibliographic Details
Published in:Physics in medicine & biology 2018-03, Vol.63 (6), p.06NT02-06NT02
Main Authors: Dekker, Kurtis H, Hazarika, Rubin, Silveira, Matheus A, Jordan, Kevin J
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c455t-a97312bea0b009d637017edb8d209e90356c5fec31fd71562ed63f57bd5627253
cites cdi_FETCH-LOGICAL-c455t-a97312bea0b009d637017edb8d209e90356c5fec31fd71562ed63f57bd5627253
container_end_page 06NT02
container_issue 6
container_start_page 06NT02
container_title Physics in medicine & biology
container_volume 63
creator Dekker, Kurtis H
Hazarika, Rubin
Silveira, Matheus A
Jordan, Kevin J
description Optical cone beam computed tomography (CT) scanning of radiochromic gel dosimeters, using a CCD camera and a low stray light convergent source, provides fast, truly 3D radiation dosimetry with high accuracy. However, a key limiting factor in radiochromic gel dosimetry at large ( 10 cm diameter) volumes is the initial attenuation of the dosimeters. It is not unusual to observe a 5-10×  difference in signal intensity through the dosimeter center versus through the surrounding medium in pre-irradiation images. Thus, all dosimetric information in a typical experiment is measured within the lower 10%-20% of the camera sensor's range, and re-use of gels is often not possible due to a lack of transmission. To counteract this, in this note we describe a simple method to create source compensators by printing on transparent films. This technique, which is easily implemented and inexpensive, is an optical analogue to the bowtie filter in x-ray CT. We present transmission images and solution phantom reconstructions to demonstrate that (1) placing compensators beyond the focal zone of the imaging lens prevents high spatial frequency features of the printed films from generating reconstruction artifacts, and (2) object-specific compensation considerably reduces the range of intensities measured in projection images. This will improve the measurable dose range in optical CT dosimetry, and will enable imaging of larger gel volumes ( 15 cm diameter). Additionally, it should enable re-use of dosimeters by printing a new compensator for a second experiment.
doi_str_mv 10.1088/1361-6560/aab17f
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2014955547</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2014955547</sourcerecordid><originalsourceid>FETCH-LOGICAL-c455t-a97312bea0b009d637017edb8d209e90356c5fec31fd71562ed63f57bd5627253</originalsourceid><addsrcrecordid>eNp1kMFLwzAUh4Mobk7vniRHD6tLmqZpjzKcCgMv8-IlpMkLZLRNTTpw_70tnbt5eo_H9_vB-xC6p-SJkqJYUZbTJOc5WSlVUWEv0Px8ukRzQhhNSsr5DN3EuCeE0iLNrtEsLXkmWCnm6GvjfsAssa_2oPskdqCddRq7toc2uv6ItW-6YVW98y22PgyHFnAFqsG-651WNV7vcFDGTYjx0TXQh-MturKqjnB3mgv0uXnZrd-S7cfr-_p5m-iM8z5RpWA0HfpIRUhpciYIFWCqwqSkhJIwnmtuQTNqjaA8T2FgLBeVGXaRcrZAj1NvF_z3AWIvGxc11LVqwR-iTAnNSs7HjxeITKgOPsYAVnbBNSocJSVyNCpHfXLUJyejQ-Th1H6oGjDnwJ_CAVhOgPOd3PtDaIdn_-_7BbHHf_w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2014955547</pqid></control><display><type>article</type><title>Fixed, object-specific intensity compensation for cone beam optical CT radiation dosimetry</title><source>Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)</source><creator>Dekker, Kurtis H ; Hazarika, Rubin ; Silveira, Matheus A ; Jordan, Kevin J</creator><creatorcontrib>Dekker, Kurtis H ; Hazarika, Rubin ; Silveira, Matheus A ; Jordan, Kevin J</creatorcontrib><description>Optical cone beam computed tomography (CT) scanning of radiochromic gel dosimeters, using a CCD camera and a low stray light convergent source, provides fast, truly 3D radiation dosimetry with high accuracy. However, a key limiting factor in radiochromic gel dosimetry at large ( 10 cm diameter) volumes is the initial attenuation of the dosimeters. It is not unusual to observe a 5-10×  difference in signal intensity through the dosimeter center versus through the surrounding medium in pre-irradiation images. Thus, all dosimetric information in a typical experiment is measured within the lower 10%-20% of the camera sensor's range, and re-use of gels is often not possible due to a lack of transmission. To counteract this, in this note we describe a simple method to create source compensators by printing on transparent films. This technique, which is easily implemented and inexpensive, is an optical analogue to the bowtie filter in x-ray CT. We present transmission images and solution phantom reconstructions to demonstrate that (1) placing compensators beyond the focal zone of the imaging lens prevents high spatial frequency features of the printed films from generating reconstruction artifacts, and (2) object-specific compensation considerably reduces the range of intensities measured in projection images. This will improve the measurable dose range in optical CT dosimetry, and will enable imaging of larger gel volumes ( 15 cm diameter). Additionally, it should enable re-use of dosimeters by printing a new compensator for a second experiment.</description><identifier>ISSN: 0031-9155</identifier><identifier>ISSN: 1361-6560</identifier><identifier>EISSN: 1361-6560</identifier><identifier>DOI: 10.1088/1361-6560/aab17f</identifier><identifier>PMID: 29547397</identifier><identifier>CODEN: PHMBA7</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>3D radiation dosimetry ; cone beam CT ; optical CT ; source compensator</subject><ispartof>Physics in medicine &amp; biology, 2018-03, Vol.63 (6), p.06NT02-06NT02</ispartof><rights>2018 Institute of Physics and Engineering in Medicine</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c455t-a97312bea0b009d637017edb8d209e90356c5fec31fd71562ed63f57bd5627253</citedby><cites>FETCH-LOGICAL-c455t-a97312bea0b009d637017edb8d209e90356c5fec31fd71562ed63f57bd5627253</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29547397$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Dekker, Kurtis H</creatorcontrib><creatorcontrib>Hazarika, Rubin</creatorcontrib><creatorcontrib>Silveira, Matheus A</creatorcontrib><creatorcontrib>Jordan, Kevin J</creatorcontrib><title>Fixed, object-specific intensity compensation for cone beam optical CT radiation dosimetry</title><title>Physics in medicine &amp; biology</title><addtitle>PMB</addtitle><addtitle>Phys. Med. Biol</addtitle><description>Optical cone beam computed tomography (CT) scanning of radiochromic gel dosimeters, using a CCD camera and a low stray light convergent source, provides fast, truly 3D radiation dosimetry with high accuracy. However, a key limiting factor in radiochromic gel dosimetry at large ( 10 cm diameter) volumes is the initial attenuation of the dosimeters. It is not unusual to observe a 5-10×  difference in signal intensity through the dosimeter center versus through the surrounding medium in pre-irradiation images. Thus, all dosimetric information in a typical experiment is measured within the lower 10%-20% of the camera sensor's range, and re-use of gels is often not possible due to a lack of transmission. To counteract this, in this note we describe a simple method to create source compensators by printing on transparent films. This technique, which is easily implemented and inexpensive, is an optical analogue to the bowtie filter in x-ray CT. We present transmission images and solution phantom reconstructions to demonstrate that (1) placing compensators beyond the focal zone of the imaging lens prevents high spatial frequency features of the printed films from generating reconstruction artifacts, and (2) object-specific compensation considerably reduces the range of intensities measured in projection images. This will improve the measurable dose range in optical CT dosimetry, and will enable imaging of larger gel volumes ( 15 cm diameter). Additionally, it should enable re-use of dosimeters by printing a new compensator for a second experiment.</description><subject>3D radiation dosimetry</subject><subject>cone beam CT</subject><subject>optical CT</subject><subject>source compensator</subject><issn>0031-9155</issn><issn>1361-6560</issn><issn>1361-6560</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp1kMFLwzAUh4Mobk7vniRHD6tLmqZpjzKcCgMv8-IlpMkLZLRNTTpw_70tnbt5eo_H9_vB-xC6p-SJkqJYUZbTJOc5WSlVUWEv0Px8ukRzQhhNSsr5DN3EuCeE0iLNrtEsLXkmWCnm6GvjfsAssa_2oPskdqCddRq7toc2uv6ItW-6YVW98y22PgyHFnAFqsG-651WNV7vcFDGTYjx0TXQh-MturKqjnB3mgv0uXnZrd-S7cfr-_p5m-iM8z5RpWA0HfpIRUhpciYIFWCqwqSkhJIwnmtuQTNqjaA8T2FgLBeVGXaRcrZAj1NvF_z3AWIvGxc11LVqwR-iTAnNSs7HjxeITKgOPsYAVnbBNSocJSVyNCpHfXLUJyejQ-Th1H6oGjDnwJ_CAVhOgPOd3PtDaIdn_-_7BbHHf_w</recordid><startdate>20180316</startdate><enddate>20180316</enddate><creator>Dekker, Kurtis H</creator><creator>Hazarika, Rubin</creator><creator>Silveira, Matheus A</creator><creator>Jordan, Kevin J</creator><general>IOP Publishing</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20180316</creationdate><title>Fixed, object-specific intensity compensation for cone beam optical CT radiation dosimetry</title><author>Dekker, Kurtis H ; Hazarika, Rubin ; Silveira, Matheus A ; Jordan, Kevin J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c455t-a97312bea0b009d637017edb8d209e90356c5fec31fd71562ed63f57bd5627253</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>3D radiation dosimetry</topic><topic>cone beam CT</topic><topic>optical CT</topic><topic>source compensator</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dekker, Kurtis H</creatorcontrib><creatorcontrib>Hazarika, Rubin</creatorcontrib><creatorcontrib>Silveira, Matheus A</creatorcontrib><creatorcontrib>Jordan, Kevin J</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physics in medicine &amp; biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Dekker, Kurtis H</au><au>Hazarika, Rubin</au><au>Silveira, Matheus A</au><au>Jordan, Kevin J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fixed, object-specific intensity compensation for cone beam optical CT radiation dosimetry</atitle><jtitle>Physics in medicine &amp; biology</jtitle><stitle>PMB</stitle><addtitle>Phys. Med. Biol</addtitle><date>2018-03-16</date><risdate>2018</risdate><volume>63</volume><issue>6</issue><spage>06NT02</spage><epage>06NT02</epage><pages>06NT02-06NT02</pages><issn>0031-9155</issn><issn>1361-6560</issn><eissn>1361-6560</eissn><coden>PHMBA7</coden><abstract>Optical cone beam computed tomography (CT) scanning of radiochromic gel dosimeters, using a CCD camera and a low stray light convergent source, provides fast, truly 3D radiation dosimetry with high accuracy. However, a key limiting factor in radiochromic gel dosimetry at large ( 10 cm diameter) volumes is the initial attenuation of the dosimeters. It is not unusual to observe a 5-10×  difference in signal intensity through the dosimeter center versus through the surrounding medium in pre-irradiation images. Thus, all dosimetric information in a typical experiment is measured within the lower 10%-20% of the camera sensor's range, and re-use of gels is often not possible due to a lack of transmission. To counteract this, in this note we describe a simple method to create source compensators by printing on transparent films. This technique, which is easily implemented and inexpensive, is an optical analogue to the bowtie filter in x-ray CT. We present transmission images and solution phantom reconstructions to demonstrate that (1) placing compensators beyond the focal zone of the imaging lens prevents high spatial frequency features of the printed films from generating reconstruction artifacts, and (2) object-specific compensation considerably reduces the range of intensities measured in projection images. This will improve the measurable dose range in optical CT dosimetry, and will enable imaging of larger gel volumes ( 15 cm diameter). Additionally, it should enable re-use of dosimeters by printing a new compensator for a second experiment.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>29547397</pmid><doi>10.1088/1361-6560/aab17f</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0031-9155
ispartof Physics in medicine & biology, 2018-03, Vol.63 (6), p.06NT02-06NT02
issn 0031-9155
1361-6560
1361-6560
language eng
recordid cdi_proquest_miscellaneous_2014955547
source Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)
subjects 3D radiation dosimetry
cone beam CT
optical CT
source compensator
title Fixed, object-specific intensity compensation for cone beam optical CT radiation dosimetry
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T10%3A11%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fixed,%20object-specific%20intensity%20compensation%20for%20cone%20beam%20optical%20CT%20radiation%20dosimetry&rft.jtitle=Physics%20in%20medicine%20&%20biology&rft.au=Dekker,%20Kurtis%20H&rft.date=2018-03-16&rft.volume=63&rft.issue=6&rft.spage=06NT02&rft.epage=06NT02&rft.pages=06NT02-06NT02&rft.issn=0031-9155&rft.eissn=1361-6560&rft.coden=PHMBA7&rft_id=info:doi/10.1088/1361-6560/aab17f&rft_dat=%3Cproquest_cross%3E2014955547%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c455t-a97312bea0b009d637017edb8d209e90356c5fec31fd71562ed63f57bd5627253%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2014955547&rft_id=info:pmid/29547397&rfr_iscdi=true