Loading…
Fe3O4-decorated graphene assembled porous carbon nanocomposite for ammonia sensing: study using an optical fiber Fabry–Perot interferometer
A porous graphene-coated optical fiber Fabry–Perot interferometer (G-FPI) and Fe3O4-graphene nanocomposite coated Fabry–Perot interferometer (FG-FPI) have been investigated and compared for the detection of ammonia gas at room temperature. The sensor probes were subjected to ammonia concentrations v...
Saved in:
Published in: | Analyst (London) 2018-04, Vol.143 (8), p.1890-1898 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 1898 |
container_issue | 8 |
container_start_page | 1890 |
container_title | Analyst (London) |
container_volume | 143 |
creator | Pawar, Dnyandeo Bhaskara Rao, B V Kale, S N |
description | A porous graphene-coated optical fiber Fabry–Perot interferometer (G-FPI) and Fe3O4-graphene nanocomposite coated Fabry–Perot interferometer (FG-FPI) have been investigated and compared for the detection of ammonia gas at room temperature. The sensor probes were subjected to ammonia concentrations varying from 1.5 ppm to 150 ppm. An increased sensitivity was observed for FG-FPI (36 pm ppm−1) when compared with that of G-FPI (25 pm ppm−1). The observed sensor detection limits for FG-FPI and G-FPI were around 7 and 10 ppb, respectively. The sensing mechanism was based on the change in refractive index/dielectric constant of the material; which changed the conductivity of coated material in presence of NH3. It was observed that the modified refractive index induced a wavelength shift in the FPI. The highly porous structure of graphene and the uniform dispersion of Fe3O4 nanoparticles into this framework effectively facilitated the target gas diffusion and hence improved the sensing performance. The sensing was correlated to the oxygen vacancies on the Fe3O4 surfaces and the depletion region manipulations with the ammonia interactions along with Schottky-type electron conductivity via the conducting graphene assembled porous carbon framework. The mathematical evaluation of the phenomenon also justified the excellent repeatability and reversibility of this sensitive, room temperature sensor. |
doi_str_mv | 10.1039/c7an01891f |
format | article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_2016540507</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2016540507</sourcerecordid><originalsourceid>FETCH-LOGICAL-p216t-9f806c0ce9e5575477b34b320094ce6f0115d172ef5958f92bb2ef8f09e0c643</originalsourceid><addsrcrecordid>eNpdkL1OwzAUhS0EEqWw8ASWWFgC_omTmA1VFJAqlaF7ZTvXJVViB9sZuvECTLwhT4IRTEz3O1dHV_cchC4puaGEy1tTK0doI6k9QjPKq7IQgjXHaEYI4QWrRHmKzmLcZ0mJIDP0sQS-LosWjA8qQYt3QY2v4ACrGGHQfV6NPvgpYqOC9g475bzxw-hjlwBbH7AaBu86hSO42LndHY5pag94-hFYOezH1BnVY9tpCHipdDh8vX--QPAJdy5BsBkHyHCOTqzqI1z8zTnaLB82i6ditX58XtyvipHRKhXSNqQyxIAEIWpR1rXmpeaMEFkaqCyhVLS0ZmCFFI2VTOvMjSUSiKlKPkfXv2fH4N8miGk7dNFA3ysHOemWEZqbyv3U2Xr1z7r3U3D5uexigou6oZx_A1zvddM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2025357813</pqid></control><display><type>article</type><title>Fe3O4-decorated graphene assembled porous carbon nanocomposite for ammonia sensing: study using an optical fiber Fabry–Perot interferometer</title><source>Royal Society of Chemistry</source><creator>Pawar, Dnyandeo ; Bhaskara Rao, B V ; Kale, S N</creator><creatorcontrib>Pawar, Dnyandeo ; Bhaskara Rao, B V ; Kale, S N</creatorcontrib><description>A porous graphene-coated optical fiber Fabry–Perot interferometer (G-FPI) and Fe3O4-graphene nanocomposite coated Fabry–Perot interferometer (FG-FPI) have been investigated and compared for the detection of ammonia gas at room temperature. The sensor probes were subjected to ammonia concentrations varying from 1.5 ppm to 150 ppm. An increased sensitivity was observed for FG-FPI (36 pm ppm−1) when compared with that of G-FPI (25 pm ppm−1). The observed sensor detection limits for FG-FPI and G-FPI were around 7 and 10 ppb, respectively. The sensing mechanism was based on the change in refractive index/dielectric constant of the material; which changed the conductivity of coated material in presence of NH3. It was observed that the modified refractive index induced a wavelength shift in the FPI. The highly porous structure of graphene and the uniform dispersion of Fe3O4 nanoparticles into this framework effectively facilitated the target gas diffusion and hence improved the sensing performance. The sensing was correlated to the oxygen vacancies on the Fe3O4 surfaces and the depletion region manipulations with the ammonia interactions along with Schottky-type electron conductivity via the conducting graphene assembled porous carbon framework. The mathematical evaluation of the phenomenon also justified the excellent repeatability and reversibility of this sensitive, room temperature sensor.</description><identifier>ISSN: 0003-2654</identifier><identifier>EISSN: 1364-5528</identifier><identifier>DOI: 10.1039/c7an01891f</identifier><language>eng</language><publisher>London: Royal Society of Chemistry</publisher><subject>Ammonia ; Detection ; Electron conductivity ; Fabry-Perot interferometers ; Gaseous diffusion ; Graphene ; Iron oxides ; Nanocomposites ; Refractivity ; Sensors ; Temperature sensors</subject><ispartof>Analyst (London), 2018-04, Vol.143 (8), p.1890-1898</ispartof><rights>Copyright Royal Society of Chemistry 2018</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Pawar, Dnyandeo</creatorcontrib><creatorcontrib>Bhaskara Rao, B V</creatorcontrib><creatorcontrib>Kale, S N</creatorcontrib><title>Fe3O4-decorated graphene assembled porous carbon nanocomposite for ammonia sensing: study using an optical fiber Fabry–Perot interferometer</title><title>Analyst (London)</title><description>A porous graphene-coated optical fiber Fabry–Perot interferometer (G-FPI) and Fe3O4-graphene nanocomposite coated Fabry–Perot interferometer (FG-FPI) have been investigated and compared for the detection of ammonia gas at room temperature. The sensor probes were subjected to ammonia concentrations varying from 1.5 ppm to 150 ppm. An increased sensitivity was observed for FG-FPI (36 pm ppm−1) when compared with that of G-FPI (25 pm ppm−1). The observed sensor detection limits for FG-FPI and G-FPI were around 7 and 10 ppb, respectively. The sensing mechanism was based on the change in refractive index/dielectric constant of the material; which changed the conductivity of coated material in presence of NH3. It was observed that the modified refractive index induced a wavelength shift in the FPI. The highly porous structure of graphene and the uniform dispersion of Fe3O4 nanoparticles into this framework effectively facilitated the target gas diffusion and hence improved the sensing performance. The sensing was correlated to the oxygen vacancies on the Fe3O4 surfaces and the depletion region manipulations with the ammonia interactions along with Schottky-type electron conductivity via the conducting graphene assembled porous carbon framework. The mathematical evaluation of the phenomenon also justified the excellent repeatability and reversibility of this sensitive, room temperature sensor.</description><subject>Ammonia</subject><subject>Detection</subject><subject>Electron conductivity</subject><subject>Fabry-Perot interferometers</subject><subject>Gaseous diffusion</subject><subject>Graphene</subject><subject>Iron oxides</subject><subject>Nanocomposites</subject><subject>Refractivity</subject><subject>Sensors</subject><subject>Temperature sensors</subject><issn>0003-2654</issn><issn>1364-5528</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNpdkL1OwzAUhS0EEqWw8ASWWFgC_omTmA1VFJAqlaF7ZTvXJVViB9sZuvECTLwhT4IRTEz3O1dHV_cchC4puaGEy1tTK0doI6k9QjPKq7IQgjXHaEYI4QWrRHmKzmLcZ0mJIDP0sQS-LosWjA8qQYt3QY2v4ACrGGHQfV6NPvgpYqOC9g475bzxw-hjlwBbH7AaBu86hSO42LndHY5pag94-hFYOezH1BnVY9tpCHipdDh8vX--QPAJdy5BsBkHyHCOTqzqI1z8zTnaLB82i6ditX58XtyvipHRKhXSNqQyxIAEIWpR1rXmpeaMEFkaqCyhVLS0ZmCFFI2VTOvMjSUSiKlKPkfXv2fH4N8miGk7dNFA3ysHOemWEZqbyv3U2Xr1z7r3U3D5uexigou6oZx_A1zvddM</recordid><startdate>20180421</startdate><enddate>20180421</enddate><creator>Pawar, Dnyandeo</creator><creator>Bhaskara Rao, B V</creator><creator>Kale, S N</creator><general>Royal Society of Chemistry</general><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope><scope>7X8</scope></search><sort><creationdate>20180421</creationdate><title>Fe3O4-decorated graphene assembled porous carbon nanocomposite for ammonia sensing: study using an optical fiber Fabry–Perot interferometer</title><author>Pawar, Dnyandeo ; Bhaskara Rao, B V ; Kale, S N</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p216t-9f806c0ce9e5575477b34b320094ce6f0115d172ef5958f92bb2ef8f09e0c643</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Ammonia</topic><topic>Detection</topic><topic>Electron conductivity</topic><topic>Fabry-Perot interferometers</topic><topic>Gaseous diffusion</topic><topic>Graphene</topic><topic>Iron oxides</topic><topic>Nanocomposites</topic><topic>Refractivity</topic><topic>Sensors</topic><topic>Temperature sensors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pawar, Dnyandeo</creatorcontrib><creatorcontrib>Bhaskara Rao, B V</creatorcontrib><creatorcontrib>Kale, S N</creatorcontrib><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Analyst (London)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pawar, Dnyandeo</au><au>Bhaskara Rao, B V</au><au>Kale, S N</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fe3O4-decorated graphene assembled porous carbon nanocomposite for ammonia sensing: study using an optical fiber Fabry–Perot interferometer</atitle><jtitle>Analyst (London)</jtitle><date>2018-04-21</date><risdate>2018</risdate><volume>143</volume><issue>8</issue><spage>1890</spage><epage>1898</epage><pages>1890-1898</pages><issn>0003-2654</issn><eissn>1364-5528</eissn><abstract>A porous graphene-coated optical fiber Fabry–Perot interferometer (G-FPI) and Fe3O4-graphene nanocomposite coated Fabry–Perot interferometer (FG-FPI) have been investigated and compared for the detection of ammonia gas at room temperature. The sensor probes were subjected to ammonia concentrations varying from 1.5 ppm to 150 ppm. An increased sensitivity was observed for FG-FPI (36 pm ppm−1) when compared with that of G-FPI (25 pm ppm−1). The observed sensor detection limits for FG-FPI and G-FPI were around 7 and 10 ppb, respectively. The sensing mechanism was based on the change in refractive index/dielectric constant of the material; which changed the conductivity of coated material in presence of NH3. It was observed that the modified refractive index induced a wavelength shift in the FPI. The highly porous structure of graphene and the uniform dispersion of Fe3O4 nanoparticles into this framework effectively facilitated the target gas diffusion and hence improved the sensing performance. The sensing was correlated to the oxygen vacancies on the Fe3O4 surfaces and the depletion region manipulations with the ammonia interactions along with Schottky-type electron conductivity via the conducting graphene assembled porous carbon framework. The mathematical evaluation of the phenomenon also justified the excellent repeatability and reversibility of this sensitive, room temperature sensor.</abstract><cop>London</cop><pub>Royal Society of Chemistry</pub><doi>10.1039/c7an01891f</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2654 |
ispartof | Analyst (London), 2018-04, Vol.143 (8), p.1890-1898 |
issn | 0003-2654 1364-5528 |
language | eng |
recordid | cdi_proquest_miscellaneous_2016540507 |
source | Royal Society of Chemistry |
subjects | Ammonia Detection Electron conductivity Fabry-Perot interferometers Gaseous diffusion Graphene Iron oxides Nanocomposites Refractivity Sensors Temperature sensors |
title | Fe3O4-decorated graphene assembled porous carbon nanocomposite for ammonia sensing: study using an optical fiber Fabry–Perot interferometer |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T12%3A09%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fe3O4-decorated%20graphene%20assembled%20porous%20carbon%20nanocomposite%20for%20ammonia%20sensing:%20study%20using%20an%20optical%20fiber%20Fabry%E2%80%93Perot%20interferometer&rft.jtitle=Analyst%20(London)&rft.au=Pawar,%20Dnyandeo&rft.date=2018-04-21&rft.volume=143&rft.issue=8&rft.spage=1890&rft.epage=1898&rft.pages=1890-1898&rft.issn=0003-2654&rft.eissn=1364-5528&rft_id=info:doi/10.1039/c7an01891f&rft_dat=%3Cproquest%3E2016540507%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-p216t-9f806c0ce9e5575477b34b320094ce6f0115d172ef5958f92bb2ef8f09e0c643%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2025357813&rft_id=info:pmid/&rfr_iscdi=true |