Loading…
Value of Artisanal Simulators to Teach Ultrasound-Guided Percutaneous Biopsy Using a Tru-Cut Needle for Veterinary and Medical Students
The present study aimed to evaluate the applicability of artisanal simulators to teach veterinary and medical students the ultrasound-guided percutaneous biopsy using a tru-cut needle. The artisanal simulators consisted of bovine liver between two layers of commercially available grape gelatin. Stud...
Saved in:
Published in: | Advances in physiology education 2018-06, Vol.42 (2), p.209-214 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c391t-3d197a1f95d1650e67d70f19d4159f58704422ec57287220ec85846600a6cf563 |
---|---|
cites | cdi_FETCH-LOGICAL-c391t-3d197a1f95d1650e67d70f19d4159f58704422ec57287220ec85846600a6cf563 |
container_end_page | 214 |
container_issue | 2 |
container_start_page | 209 |
container_title | Advances in physiology education |
container_volume | 42 |
creator | de Araújo Setin, Raíza Fortes Cirimbelli, Carolina Mazeto Ercolin, Anna Carolina Pires, Sâmara Turbay Disselli, Tamiris Ferrarini Nunes Soares Hage, Maria Cristina |
description | The present study aimed to evaluate the applicability of artisanal simulators to teach veterinary and medical students the ultrasound-guided percutaneous biopsy using a tru-cut needle. The artisanal simulators consisted of bovine liver between two layers of commercially available grape gelatin. Students were paired, with one doing the biopsy and the other the ultrasound guidance. After performing the biopsies, each student answered a questionnaire with close-ended questions using a visual analog scale. The evaluated items were realism of the model, liver scanning, procedure instructions, biopsy feasibility, tru-cut needle handling, technique learning,and confidence to perform in vivo procedures. Items that received a score of 7 or higher were considered strong items; items with a score between 5 and 6.9 were classified as average items; and items with a score of 5 or lower were considered weak items. The answers to all questions had an average score of 7 or higher, suggesting that the simulator was classified as strong for all of the evaluated items. Answers to question 7 suggested that some of the students did not develop confidence to perform a tru-cut biopsy on a patient. Students evaluated the artisanal simulator as a strong method to be used in ultrasound-guided percutaneous biopsy with a tru-cut needle. Additionally,the model presented a low cost of production and was proven accurate to teach biopsy skills in health professional schools dealing with veterinary or human medicine |
doi_str_mv | 10.1152/advan.00185.2017 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2021730827</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ericid>EJ1175138</ericid><sourcerecordid>2021730827</sourcerecordid><originalsourceid>FETCH-LOGICAL-c391t-3d197a1f95d1650e67d70f19d4159f58704422ec57287220ec85846600a6cf563</originalsourceid><addsrcrecordid>eNpdkctuFDEQRS0EIiGwZwOylA2bHsru9qOXYZQHKAEkZrJtGbsaHPW0Bz-Q8gX8djyZkEXkhS37VFm3DiFvGSwYE_yjcX_NvABgWiw4MPWMHNZr3jDO--f1DF3bdNDJA_IqpRsAUJ1uX5ID3ksmhVSH5N-1mQrSMNKTmH0ys5noD78pk8khJpoDXaGxv-l6ytGkUGbXnBfv0NHvGG3JZsZQEv3kwzbd0nXy8y9q6CqWZlky_YroJqRjiPQaM0Y_m3hLzezoFTpvd3_l4nDO6TV5MZop4ZuH_Yisz05Xy4vm8tv55-XJZWPbnuWmdaxXho29cDUAoFROwch61zHRj0Ir6DrO0QrFteIc0GqhOykBjLSjkO0R-bDvu43hT8GUh41PFqdpH2TgwJlqQXNV0eMn6E0osQ5oRymupK6rUrCnbAwpRRyHbfSbGnNgMOwkDfeShntJw05SLXn_0Lj83KB7LPhvpQLv9kCdmH18Pv3CmBKs1e0d49-Wpw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2072768686</pqid></control><display><type>article</type><title>Value of Artisanal Simulators to Teach Ultrasound-Guided Percutaneous Biopsy Using a Tru-Cut Needle for Veterinary and Medical Students</title><source>American Physiological Society Free</source><source>ERIC</source><creator>de Araújo Setin, Raíza ; Fortes Cirimbelli, Carolina ; Mazeto Ercolin, Anna Carolina ; Pires, Sâmara Turbay ; Disselli, Tamiris ; Ferrarini Nunes Soares Hage, Maria Cristina</creator><creatorcontrib>de Araújo Setin, Raíza ; Fortes Cirimbelli, Carolina ; Mazeto Ercolin, Anna Carolina ; Pires, Sâmara Turbay ; Disselli, Tamiris ; Ferrarini Nunes Soares Hage, Maria Cristina</creatorcontrib><description>The present study aimed to evaluate the applicability of artisanal simulators to teach veterinary and medical students the ultrasound-guided percutaneous biopsy using a tru-cut needle. The artisanal simulators consisted of bovine liver between two layers of commercially available grape gelatin. Students were paired, with one doing the biopsy and the other the ultrasound guidance. After performing the biopsies, each student answered a questionnaire with close-ended questions using a visual analog scale. The evaluated items were realism of the model, liver scanning, procedure instructions, biopsy feasibility, tru-cut needle handling, technique learning,and confidence to perform in vivo procedures. Items that received a score of 7 or higher were considered strong items; items with a score between 5 and 6.9 were classified as average items; and items with a score of 5 or lower were considered weak items. The answers to all questions had an average score of 7 or higher, suggesting that the simulator was classified as strong for all of the evaluated items. Answers to question 7 suggested that some of the students did not develop confidence to perform a tru-cut biopsy on a patient. Students evaluated the artisanal simulator as a strong method to be used in ultrasound-guided percutaneous biopsy with a tru-cut needle. Additionally,the model presented a low cost of production and was proven accurate to teach biopsy skills in health professional schools dealing with veterinary or human medicine</description><identifier>ISSN: 1043-4046</identifier><identifier>EISSN: 1522-1229</identifier><identifier>DOI: 10.1152/advan.00185.2017</identifier><identifier>PMID: 29616567</identifier><language>eng</language><publisher>United States: American Physiological Society</publisher><subject>Animals ; Biopsy ; Biopsy, Needle - instrumentation ; Biopsy, Needle - methods ; Cattle ; Clinical medicine ; Diagnostic Tests ; Education, Veterinary - methods ; Foreign Countries ; Gelatin ; Humans ; Instructional Effectiveness ; Liver ; Liver - diagnostic imaging ; Liver - pathology ; Medical Education ; Medical personnel ; Medical students ; Models, Anatomic ; Questionnaires ; Scores ; Simulation ; Simulators ; Statistical Analysis ; Students, Medical ; Teaching Methods ; Ultrasonic imaging ; Ultrasonography, Interventional - instrumentation ; Ultrasonography, Interventional - methods ; Ultrasound ; Veterinary Medical Education ; Veterinary medicine</subject><ispartof>Advances in physiology education, 2018-06, Vol.42 (2), p.209-214</ispartof><rights>Copyright American Physiological Society Jun 2018</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c391t-3d197a1f95d1650e67d70f19d4159f58704422ec57287220ec85846600a6cf563</citedby><cites>FETCH-LOGICAL-c391t-3d197a1f95d1650e67d70f19d4159f58704422ec57287220ec85846600a6cf563</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://eric.ed.gov/ERICWebPortal/detail?accno=EJ1175138$$DView record in ERIC$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29616567$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>de Araújo Setin, Raíza</creatorcontrib><creatorcontrib>Fortes Cirimbelli, Carolina</creatorcontrib><creatorcontrib>Mazeto Ercolin, Anna Carolina</creatorcontrib><creatorcontrib>Pires, Sâmara Turbay</creatorcontrib><creatorcontrib>Disselli, Tamiris</creatorcontrib><creatorcontrib>Ferrarini Nunes Soares Hage, Maria Cristina</creatorcontrib><title>Value of Artisanal Simulators to Teach Ultrasound-Guided Percutaneous Biopsy Using a Tru-Cut Needle for Veterinary and Medical Students</title><title>Advances in physiology education</title><addtitle>Adv Physiol Educ</addtitle><description>The present study aimed to evaluate the applicability of artisanal simulators to teach veterinary and medical students the ultrasound-guided percutaneous biopsy using a tru-cut needle. The artisanal simulators consisted of bovine liver between two layers of commercially available grape gelatin. Students were paired, with one doing the biopsy and the other the ultrasound guidance. After performing the biopsies, each student answered a questionnaire with close-ended questions using a visual analog scale. The evaluated items were realism of the model, liver scanning, procedure instructions, biopsy feasibility, tru-cut needle handling, technique learning,and confidence to perform in vivo procedures. Items that received a score of 7 or higher were considered strong items; items with a score between 5 and 6.9 were classified as average items; and items with a score of 5 or lower were considered weak items. The answers to all questions had an average score of 7 or higher, suggesting that the simulator was classified as strong for all of the evaluated items. Answers to question 7 suggested that some of the students did not develop confidence to perform a tru-cut biopsy on a patient. Students evaluated the artisanal simulator as a strong method to be used in ultrasound-guided percutaneous biopsy with a tru-cut needle. Additionally,the model presented a low cost of production and was proven accurate to teach biopsy skills in health professional schools dealing with veterinary or human medicine</description><subject>Animals</subject><subject>Biopsy</subject><subject>Biopsy, Needle - instrumentation</subject><subject>Biopsy, Needle - methods</subject><subject>Cattle</subject><subject>Clinical medicine</subject><subject>Diagnostic Tests</subject><subject>Education, Veterinary - methods</subject><subject>Foreign Countries</subject><subject>Gelatin</subject><subject>Humans</subject><subject>Instructional Effectiveness</subject><subject>Liver</subject><subject>Liver - diagnostic imaging</subject><subject>Liver - pathology</subject><subject>Medical Education</subject><subject>Medical personnel</subject><subject>Medical students</subject><subject>Models, Anatomic</subject><subject>Questionnaires</subject><subject>Scores</subject><subject>Simulation</subject><subject>Simulators</subject><subject>Statistical Analysis</subject><subject>Students, Medical</subject><subject>Teaching Methods</subject><subject>Ultrasonic imaging</subject><subject>Ultrasonography, Interventional - instrumentation</subject><subject>Ultrasonography, Interventional - methods</subject><subject>Ultrasound</subject><subject>Veterinary Medical Education</subject><subject>Veterinary medicine</subject><issn>1043-4046</issn><issn>1522-1229</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>7SW</sourceid><recordid>eNpdkctuFDEQRS0EIiGwZwOylA2bHsru9qOXYZQHKAEkZrJtGbsaHPW0Bz-Q8gX8djyZkEXkhS37VFm3DiFvGSwYE_yjcX_NvABgWiw4MPWMHNZr3jDO--f1DF3bdNDJA_IqpRsAUJ1uX5ID3ksmhVSH5N-1mQrSMNKTmH0ys5noD78pk8khJpoDXaGxv-l6ytGkUGbXnBfv0NHvGG3JZsZQEv3kwzbd0nXy8y9q6CqWZlky_YroJqRjiPQaM0Y_m3hLzezoFTpvd3_l4nDO6TV5MZop4ZuH_Yisz05Xy4vm8tv55-XJZWPbnuWmdaxXho29cDUAoFROwch61zHRj0Ir6DrO0QrFteIc0GqhOykBjLSjkO0R-bDvu43hT8GUh41PFqdpH2TgwJlqQXNV0eMn6E0osQ5oRymupK6rUrCnbAwpRRyHbfSbGnNgMOwkDfeShntJw05SLXn_0Lj83KB7LPhvpQLv9kCdmH18Pv3CmBKs1e0d49-Wpw</recordid><startdate>201806</startdate><enddate>201806</enddate><creator>de Araújo Setin, Raíza</creator><creator>Fortes Cirimbelli, Carolina</creator><creator>Mazeto Ercolin, Anna Carolina</creator><creator>Pires, Sâmara Turbay</creator><creator>Disselli, Tamiris</creator><creator>Ferrarini Nunes Soares Hage, Maria Cristina</creator><general>American Physiological Society</general><scope>7SW</scope><scope>BJH</scope><scope>BNH</scope><scope>BNI</scope><scope>BNJ</scope><scope>BNO</scope><scope>ERI</scope><scope>PET</scope><scope>REK</scope><scope>WWN</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TS</scope><scope>7X8</scope></search><sort><creationdate>201806</creationdate><title>Value of Artisanal Simulators to Teach Ultrasound-Guided Percutaneous Biopsy Using a Tru-Cut Needle for Veterinary and Medical Students</title><author>de Araújo Setin, Raíza ; Fortes Cirimbelli, Carolina ; Mazeto Ercolin, Anna Carolina ; Pires, Sâmara Turbay ; Disselli, Tamiris ; Ferrarini Nunes Soares Hage, Maria Cristina</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c391t-3d197a1f95d1650e67d70f19d4159f58704422ec57287220ec85846600a6cf563</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Animals</topic><topic>Biopsy</topic><topic>Biopsy, Needle - instrumentation</topic><topic>Biopsy, Needle - methods</topic><topic>Cattle</topic><topic>Clinical medicine</topic><topic>Diagnostic Tests</topic><topic>Education, Veterinary - methods</topic><topic>Foreign Countries</topic><topic>Gelatin</topic><topic>Humans</topic><topic>Instructional Effectiveness</topic><topic>Liver</topic><topic>Liver - diagnostic imaging</topic><topic>Liver - pathology</topic><topic>Medical Education</topic><topic>Medical personnel</topic><topic>Medical students</topic><topic>Models, Anatomic</topic><topic>Questionnaires</topic><topic>Scores</topic><topic>Simulation</topic><topic>Simulators</topic><topic>Statistical Analysis</topic><topic>Students, Medical</topic><topic>Teaching Methods</topic><topic>Ultrasonic imaging</topic><topic>Ultrasonography, Interventional - instrumentation</topic><topic>Ultrasonography, Interventional - methods</topic><topic>Ultrasound</topic><topic>Veterinary Medical Education</topic><topic>Veterinary medicine</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>de Araújo Setin, Raíza</creatorcontrib><creatorcontrib>Fortes Cirimbelli, Carolina</creatorcontrib><creatorcontrib>Mazeto Ercolin, Anna Carolina</creatorcontrib><creatorcontrib>Pires, Sâmara Turbay</creatorcontrib><creatorcontrib>Disselli, Tamiris</creatorcontrib><creatorcontrib>Ferrarini Nunes Soares Hage, Maria Cristina</creatorcontrib><collection>ERIC</collection><collection>ERIC (Ovid)</collection><collection>ERIC</collection><collection>ERIC</collection><collection>ERIC (Legacy Platform)</collection><collection>ERIC( SilverPlatter )</collection><collection>ERIC</collection><collection>ERIC PlusText (Legacy Platform)</collection><collection>Education Resources Information Center (ERIC)</collection><collection>ERIC</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Physical Education Index</collection><collection>MEDLINE - Academic</collection><jtitle>Advances in physiology education</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>de Araújo Setin, Raíza</au><au>Fortes Cirimbelli, Carolina</au><au>Mazeto Ercolin, Anna Carolina</au><au>Pires, Sâmara Turbay</au><au>Disselli, Tamiris</au><au>Ferrarini Nunes Soares Hage, Maria Cristina</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><ericid>EJ1175138</ericid><atitle>Value of Artisanal Simulators to Teach Ultrasound-Guided Percutaneous Biopsy Using a Tru-Cut Needle for Veterinary and Medical Students</atitle><jtitle>Advances in physiology education</jtitle><addtitle>Adv Physiol Educ</addtitle><date>2018-06</date><risdate>2018</risdate><volume>42</volume><issue>2</issue><spage>209</spage><epage>214</epage><pages>209-214</pages><issn>1043-4046</issn><eissn>1522-1229</eissn><abstract>The present study aimed to evaluate the applicability of artisanal simulators to teach veterinary and medical students the ultrasound-guided percutaneous biopsy using a tru-cut needle. The artisanal simulators consisted of bovine liver between two layers of commercially available grape gelatin. Students were paired, with one doing the biopsy and the other the ultrasound guidance. After performing the biopsies, each student answered a questionnaire with close-ended questions using a visual analog scale. The evaluated items were realism of the model, liver scanning, procedure instructions, biopsy feasibility, tru-cut needle handling, technique learning,and confidence to perform in vivo procedures. Items that received a score of 7 or higher were considered strong items; items with a score between 5 and 6.9 were classified as average items; and items with a score of 5 or lower were considered weak items. The answers to all questions had an average score of 7 or higher, suggesting that the simulator was classified as strong for all of the evaluated items. Answers to question 7 suggested that some of the students did not develop confidence to perform a tru-cut biopsy on a patient. Students evaluated the artisanal simulator as a strong method to be used in ultrasound-guided percutaneous biopsy with a tru-cut needle. Additionally,the model presented a low cost of production and was proven accurate to teach biopsy skills in health professional schools dealing with veterinary or human medicine</abstract><cop>United States</cop><pub>American Physiological Society</pub><pmid>29616567</pmid><doi>10.1152/advan.00185.2017</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1043-4046 |
ispartof | Advances in physiology education, 2018-06, Vol.42 (2), p.209-214 |
issn | 1043-4046 1522-1229 |
language | eng |
recordid | cdi_proquest_miscellaneous_2021730827 |
source | American Physiological Society Free; ERIC |
subjects | Animals Biopsy Biopsy, Needle - instrumentation Biopsy, Needle - methods Cattle Clinical medicine Diagnostic Tests Education, Veterinary - methods Foreign Countries Gelatin Humans Instructional Effectiveness Liver Liver - diagnostic imaging Liver - pathology Medical Education Medical personnel Medical students Models, Anatomic Questionnaires Scores Simulation Simulators Statistical Analysis Students, Medical Teaching Methods Ultrasonic imaging Ultrasonography, Interventional - instrumentation Ultrasonography, Interventional - methods Ultrasound Veterinary Medical Education Veterinary medicine |
title | Value of Artisanal Simulators to Teach Ultrasound-Guided Percutaneous Biopsy Using a Tru-Cut Needle for Veterinary and Medical Students |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T04%3A09%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Value%20of%20Artisanal%20Simulators%20to%20Teach%20Ultrasound-Guided%20Percutaneous%20Biopsy%20Using%20a%20Tru-Cut%20Needle%20for%20Veterinary%20and%20Medical%20Students&rft.jtitle=Advances%20in%20physiology%20education&rft.au=de%20Ara%C3%BAjo%20Setin,%20Ra%C3%ADza&rft.date=2018-06&rft.volume=42&rft.issue=2&rft.spage=209&rft.epage=214&rft.pages=209-214&rft.issn=1043-4046&rft.eissn=1522-1229&rft_id=info:doi/10.1152/advan.00185.2017&rft_dat=%3Cproquest_cross%3E2021730827%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c391t-3d197a1f95d1650e67d70f19d4159f58704422ec57287220ec85846600a6cf563%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2072768686&rft_id=info:pmid/29616567&rft_ericid=EJ1175138&rfr_iscdi=true |