Loading…

Measurement of water absorption capacity in wheat flour by a headspace gas chromatographic technique

The purpose of this work is to introduce a new method for quantitatively analyzing water absorption capacity in wheat flour by a headspace gas chromatographic technique. This headspace gas chromatographic technique was based on measuring the water vapor released from a series of wheat flour samples...

Full description

Saved in:
Bibliographic Details
Published in:Journal of separation science 2018-07, Vol.41 (13), p.2731-2735
Main Authors: Xie, Wei‐Qi, Yu, Kong‐Xian, Gong, Yi‐Xian
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c4057-ecf44a7e79fa1a4be4b80c3544ca127b92daa7990d1c422c8b01f9fe66c016f33
cites cdi_FETCH-LOGICAL-c4057-ecf44a7e79fa1a4be4b80c3544ca127b92daa7990d1c422c8b01f9fe66c016f33
container_end_page 2735
container_issue 13
container_start_page 2731
container_title Journal of separation science
container_volume 41
creator Xie, Wei‐Qi
Yu, Kong‐Xian
Gong, Yi‐Xian
description The purpose of this work is to introduce a new method for quantitatively analyzing water absorption capacity in wheat flour by a headspace gas chromatographic technique. This headspace gas chromatographic technique was based on measuring the water vapor released from a series of wheat flour samples with different contents of water addition. According to the different trends between the vapor and wheat flour phase before and after the water absorption capacity in wheat flour, a turning point (corresponding to water absorption capacity in wheat flour) can be obtained by fitting the data of the water gas chromatography peak area from different wheat flour samples. The data showed that the phase equilibrium in the vial can be achieved in 25 min at desired temperature (35°C). The relative standard deviation of the reaction headspace gas chromatographic technique in water absorption capacity determination was within 3.48%, the relative differences has been determined by comparing the water absorption capacity obtained from this new analytical technique with the data from the reference technique (i.e., the filtration method), which are less than 8.92%. The new headspace gas chromatographic method is automated, accurate and be a reliable tool for quantifying water absorption capacity in wheat flour in both laboratory research and mill applications.
doi_str_mv 10.1002/jssc.201800073
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2027069251</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2027069251</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4057-ecf44a7e79fa1a4be4b80c3544ca127b92daa7990d1c422c8b01f9fe66c016f33</originalsourceid><addsrcrecordid>eNqFkD1v3DAMhoUiRZOmXTsGArJ0uSsly5I1BoekH0jRIe1s0DKV88G2HMnG4f59FVx6Q5ZOJMGHL8mXsU8C1gJAftml5NYSRAUApnjDLoQW5coWQp2dctDn7H1KOwBhKgvv2Lm0WpdSqwvW_iRMS6SBxpkHz_c4U-TYpBCnuQsjdzih6-YD70a-3xLO3Pdhibw5cOS5blPuE3_ExN02hgHn8Bhx2naOz-S2Y_e00Af21mOf6ONLvGR_7m5_b76t7n99_b65uV85BaVZkfNKoSFjPQpUDammAleUSjkU0jRWtojGWmiFU1K6qgHhrSetHQjti-KSfT7qTjHktWmuhy456nscKSypliANaCtLkdHrV-gufzXm6zKlC11UtjKZWh8pF0NKkXw9xW7AeKgF1M_-18_-1yf_88DVi-zSDNSe8H-GZ0AdgX3X0-E_cvWPh4dNaa0p_gJuBZH3</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2063638987</pqid></control><display><type>article</type><title>Measurement of water absorption capacity in wheat flour by a headspace gas chromatographic technique</title><source>Wiley:Jisc Collections:Wiley Read and Publish Open Access 2024-2025 (reading list)</source><creator>Xie, Wei‐Qi ; Yu, Kong‐Xian ; Gong, Yi‐Xian</creator><creatorcontrib>Xie, Wei‐Qi ; Yu, Kong‐Xian ; Gong, Yi‐Xian</creatorcontrib><description>The purpose of this work is to introduce a new method for quantitatively analyzing water absorption capacity in wheat flour by a headspace gas chromatographic technique. This headspace gas chromatographic technique was based on measuring the water vapor released from a series of wheat flour samples with different contents of water addition. According to the different trends between the vapor and wheat flour phase before and after the water absorption capacity in wheat flour, a turning point (corresponding to water absorption capacity in wheat flour) can be obtained by fitting the data of the water gas chromatography peak area from different wheat flour samples. The data showed that the phase equilibrium in the vial can be achieved in 25 min at desired temperature (35°C). The relative standard deviation of the reaction headspace gas chromatographic technique in water absorption capacity determination was within 3.48%, the relative differences has been determined by comparing the water absorption capacity obtained from this new analytical technique with the data from the reference technique (i.e., the filtration method), which are less than 8.92%. The new headspace gas chromatographic method is automated, accurate and be a reliable tool for quantifying water absorption capacity in wheat flour in both laboratory research and mill applications.</description><identifier>ISSN: 1615-9306</identifier><identifier>EISSN: 1615-9314</identifier><identifier>DOI: 10.1002/jssc.201800073</identifier><identifier>PMID: 29665264</identifier><language>eng</language><publisher>Germany: Wiley Subscription Services, Inc</publisher><subject>Chromatography ; Flour ; Gas chromatography ; headspace ; Mortgage backed securities ; Phase equilibria ; Water absorption ; water absorption capacity ; Water gas ; Water vapor ; Wheat ; wheat flour</subject><ispartof>Journal of separation science, 2018-07, Vol.41 (13), p.2731-2735</ispartof><rights>2018 WILEY‐VCH Verlag GmbH &amp; Co. KGaA, Weinheim</rights><rights>2018 WILEY-VCH Verlag GmbH &amp; Co. KGaA, Weinheim.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4057-ecf44a7e79fa1a4be4b80c3544ca127b92daa7990d1c422c8b01f9fe66c016f33</citedby><cites>FETCH-LOGICAL-c4057-ecf44a7e79fa1a4be4b80c3544ca127b92daa7990d1c422c8b01f9fe66c016f33</cites><orcidid>0000-0002-7685-3582</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29665264$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Xie, Wei‐Qi</creatorcontrib><creatorcontrib>Yu, Kong‐Xian</creatorcontrib><creatorcontrib>Gong, Yi‐Xian</creatorcontrib><title>Measurement of water absorption capacity in wheat flour by a headspace gas chromatographic technique</title><title>Journal of separation science</title><addtitle>J Sep Sci</addtitle><description>The purpose of this work is to introduce a new method for quantitatively analyzing water absorption capacity in wheat flour by a headspace gas chromatographic technique. This headspace gas chromatographic technique was based on measuring the water vapor released from a series of wheat flour samples with different contents of water addition. According to the different trends between the vapor and wheat flour phase before and after the water absorption capacity in wheat flour, a turning point (corresponding to water absorption capacity in wheat flour) can be obtained by fitting the data of the water gas chromatography peak area from different wheat flour samples. The data showed that the phase equilibrium in the vial can be achieved in 25 min at desired temperature (35°C). The relative standard deviation of the reaction headspace gas chromatographic technique in water absorption capacity determination was within 3.48%, the relative differences has been determined by comparing the water absorption capacity obtained from this new analytical technique with the data from the reference technique (i.e., the filtration method), which are less than 8.92%. The new headspace gas chromatographic method is automated, accurate and be a reliable tool for quantifying water absorption capacity in wheat flour in both laboratory research and mill applications.</description><subject>Chromatography</subject><subject>Flour</subject><subject>Gas chromatography</subject><subject>headspace</subject><subject>Mortgage backed securities</subject><subject>Phase equilibria</subject><subject>Water absorption</subject><subject>water absorption capacity</subject><subject>Water gas</subject><subject>Water vapor</subject><subject>Wheat</subject><subject>wheat flour</subject><issn>1615-9306</issn><issn>1615-9314</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqFkD1v3DAMhoUiRZOmXTsGArJ0uSsly5I1BoekH0jRIe1s0DKV88G2HMnG4f59FVx6Q5ZOJMGHL8mXsU8C1gJAftml5NYSRAUApnjDLoQW5coWQp2dctDn7H1KOwBhKgvv2Lm0WpdSqwvW_iRMS6SBxpkHz_c4U-TYpBCnuQsjdzih6-YD70a-3xLO3Pdhibw5cOS5blPuE3_ExN02hgHn8Bhx2naOz-S2Y_e00Af21mOf6ONLvGR_7m5_b76t7n99_b65uV85BaVZkfNKoSFjPQpUDammAleUSjkU0jRWtojGWmiFU1K6qgHhrSetHQjti-KSfT7qTjHktWmuhy456nscKSypliANaCtLkdHrV-gufzXm6zKlC11UtjKZWh8pF0NKkXw9xW7AeKgF1M_-18_-1yf_88DVi-zSDNSe8H-GZ0AdgX3X0-E_cvWPh4dNaa0p_gJuBZH3</recordid><startdate>201807</startdate><enddate>201807</enddate><creator>Xie, Wei‐Qi</creator><creator>Yu, Kong‐Xian</creator><creator>Gong, Yi‐Xian</creator><general>Wiley Subscription Services, Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-7685-3582</orcidid></search><sort><creationdate>201807</creationdate><title>Measurement of water absorption capacity in wheat flour by a headspace gas chromatographic technique</title><author>Xie, Wei‐Qi ; Yu, Kong‐Xian ; Gong, Yi‐Xian</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4057-ecf44a7e79fa1a4be4b80c3544ca127b92daa7990d1c422c8b01f9fe66c016f33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Chromatography</topic><topic>Flour</topic><topic>Gas chromatography</topic><topic>headspace</topic><topic>Mortgage backed securities</topic><topic>Phase equilibria</topic><topic>Water absorption</topic><topic>water absorption capacity</topic><topic>Water gas</topic><topic>Water vapor</topic><topic>Wheat</topic><topic>wheat flour</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Xie, Wei‐Qi</creatorcontrib><creatorcontrib>Yu, Kong‐Xian</creatorcontrib><creatorcontrib>Gong, Yi‐Xian</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of separation science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Xie, Wei‐Qi</au><au>Yu, Kong‐Xian</au><au>Gong, Yi‐Xian</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Measurement of water absorption capacity in wheat flour by a headspace gas chromatographic technique</atitle><jtitle>Journal of separation science</jtitle><addtitle>J Sep Sci</addtitle><date>2018-07</date><risdate>2018</risdate><volume>41</volume><issue>13</issue><spage>2731</spage><epage>2735</epage><pages>2731-2735</pages><issn>1615-9306</issn><eissn>1615-9314</eissn><abstract>The purpose of this work is to introduce a new method for quantitatively analyzing water absorption capacity in wheat flour by a headspace gas chromatographic technique. This headspace gas chromatographic technique was based on measuring the water vapor released from a series of wheat flour samples with different contents of water addition. According to the different trends between the vapor and wheat flour phase before and after the water absorption capacity in wheat flour, a turning point (corresponding to water absorption capacity in wheat flour) can be obtained by fitting the data of the water gas chromatography peak area from different wheat flour samples. The data showed that the phase equilibrium in the vial can be achieved in 25 min at desired temperature (35°C). The relative standard deviation of the reaction headspace gas chromatographic technique in water absorption capacity determination was within 3.48%, the relative differences has been determined by comparing the water absorption capacity obtained from this new analytical technique with the data from the reference technique (i.e., the filtration method), which are less than 8.92%. The new headspace gas chromatographic method is automated, accurate and be a reliable tool for quantifying water absorption capacity in wheat flour in both laboratory research and mill applications.</abstract><cop>Germany</cop><pub>Wiley Subscription Services, Inc</pub><pmid>29665264</pmid><doi>10.1002/jssc.201800073</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0002-7685-3582</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1615-9306
ispartof Journal of separation science, 2018-07, Vol.41 (13), p.2731-2735
issn 1615-9306
1615-9314
language eng
recordid cdi_proquest_miscellaneous_2027069251
source Wiley:Jisc Collections:Wiley Read and Publish Open Access 2024-2025 (reading list)
subjects Chromatography
Flour
Gas chromatography
headspace
Mortgage backed securities
Phase equilibria
Water absorption
water absorption capacity
Water gas
Water vapor
Wheat
wheat flour
title Measurement of water absorption capacity in wheat flour by a headspace gas chromatographic technique
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-31T23%3A50%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Measurement%20of%20water%20absorption%20capacity%20in%20wheat%20flour%20by%20a%20headspace%20gas%20chromatographic%20technique&rft.jtitle=Journal%20of%20separation%20science&rft.au=Xie,%20Wei%E2%80%90Qi&rft.date=2018-07&rft.volume=41&rft.issue=13&rft.spage=2731&rft.epage=2735&rft.pages=2731-2735&rft.issn=1615-9306&rft.eissn=1615-9314&rft_id=info:doi/10.1002/jssc.201800073&rft_dat=%3Cproquest_cross%3E2027069251%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c4057-ecf44a7e79fa1a4be4b80c3544ca127b92daa7990d1c422c8b01f9fe66c016f33%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2063638987&rft_id=info:pmid/29665264&rfr_iscdi=true