Comparison of expulsions following intracesarean placement of an innovative frameless copper-releasing IUD (Gyn-CS®) versus the TCu380A: A randomized trial

The intent of this study (primary outcome measure) is to assess the expulsion rate of a newly developed copper releasing frameless intrauterine IUD GyneFix® Cesarean Section (Gyn-CS®) at 3 months' follow-up, compared to the TCu-380A IUD, inserted immediately postplacental expulsion following ce...

Full description

Saved in:
Bibliographic Details
Published in:Contraception (Stoneham) 2018-08, Vol.98 (2), p.135-140
Main Authors: Unal, Ceren, Eser, Ahmet, Tozkir, Elif, Wildemeersch, D.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c383t-4c45e591cbed9dc857ac58584271d2ae2f11a0562275db471f6258149d6323793
cites cdi_FETCH-LOGICAL-c383t-4c45e591cbed9dc857ac58584271d2ae2f11a0562275db471f6258149d6323793
container_end_page 140
container_issue 2
container_start_page 135
container_title Contraception (Stoneham)
container_volume 98
creator Unal, Ceren
Eser, Ahmet
Tozkir, Elif
Wildemeersch, D.
description The intent of this study (primary outcome measure) is to assess the expulsion rate of a newly developed copper releasing frameless intrauterine IUD GyneFix® Cesarean Section (Gyn-CS®) at 3 months' follow-up, compared to the TCu-380A IUD, inserted immediately postplacental expulsion following cesarean section delivery. This is a randomized trial from one hospital research center in Istanbul, Turkey. Eligible pregnant women, the majority undergoing elective cesarean delivery (n=106), and the remaining emergency cesarean section cases (n=34), received intracesarean insertion of Gyn-CS or TCu380A insertion. Follow-up ended with a 3 month-visit. The Zeynep Kamil University Hospital Ethics Committee approved this study. The study explores the retention of 140 insertions, 70 Gyn-CS and 70 TCu380A. There were two follow-up visits after discharge from hospital at 6 weeks and 3 months. A single Gyn-CS expulsion occurred after approximately 6 weeks likely a consequence of improper anchoring. Expulsion was more common in the TCu380 A IUD group (11.4% vs 1.4%, p=.039). There were 4 removals for medical reasons in the Gyn-CS patients and 4 in the TCu380A patients, respectively, with 4 non-medical removals occurred, 2 in each group. No serious adverse events (e.g., PID, perforation) were reported. At the study conclusion of 3 months, 61 Gyn-CS (88%) and 54 TCu380A (79%) IUDs remain in place. This immediate postplacental study in cesarean section patients suggests that the anchoring technique employed resulted in the excellent retention of Gyn-CS. Insertion was easy, safe and quick requiring minimal physician training. The possibility of direct visualization of the anchor by ultrasound at insertion and follow-up allows the surgeon to verify the position of the IUD serving to enhance provider and patient confidence and assurance. The frameless anchored intrauterine IUD is effective in minimizing displacement and expulsion. The results of this study suggest that the Gyn-CS IUD is appropriate for wider intracesarean use.
doi_str_mv 10.1016/j.contraception.2018.03.034
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2028959129</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0010782418301355</els_id><sourcerecordid>2028959129</sourcerecordid><originalsourceid>FETCH-LOGICAL-c383t-4c45e591cbed9dc857ac58584271d2ae2f11a0562275db471f6258149d6323793</originalsourceid><addsrcrecordid>eNqNkcFu1DAQhi1ERZfCKyBLXMohW9uJYwdOq1BKpUocaM-W156AV4kd7GShfZY-Aw_Bk-FoW6TekEaaGemb_9foR-gtJWtKaH22W5vgp6gNjJMLfs0IlWtS5qqeoRWVoikIp_I5WhFCSSEkq47Ry5R2hBDRcPECHbOmFrKs-Qrdt2EYdXQpeBw6DL_GuU9ZNeEu9H346fw37A5uSUfQHo99ngfw08Ln3Xkf9npye8Bd1AP0kBI2YRwhFjFvOi0alzcf8enFrS_ar39-v8N7iGlOePoO-LqdS0k27_EGR-1tGNwdWDxFp_tX6KjTfYLXD_0E3Xw6v24_F1dfLi7bzVVhSllORWUqDryhZgu2sUZyoQ2XXFZMUMs0sI5STXjNmOB2Wwna1YxLWjW2LlkpmvIEnR50xxh-zJAmNbhkoO-1hzAnxQiTTTZgC_rhgJoYUorQqTG6QcdbRYla4lE79SQetcSjSJmrytdvHozm7QD23-1jHhk4PwCQ3907iCoZB96AdRHMpGxw_2X0F8IAq4Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2028959129</pqid></control><display><type>article</type><title>Comparison of expulsions following intracesarean placement of an innovative frameless copper-releasing IUD (Gyn-CS®) versus the TCu380A: A randomized trial</title><source>ScienceDirect Freedom Collection 2022-2024</source><creator>Unal, Ceren ; Eser, Ahmet ; Tozkir, Elif ; Wildemeersch, D.</creator><creatorcontrib>Unal, Ceren ; Eser, Ahmet ; Tozkir, Elif ; Wildemeersch, D.</creatorcontrib><description>The intent of this study (primary outcome measure) is to assess the expulsion rate of a newly developed copper releasing frameless intrauterine IUD GyneFix® Cesarean Section (Gyn-CS®) at 3 months' follow-up, compared to the TCu-380A IUD, inserted immediately postplacental expulsion following cesarean section delivery. This is a randomized trial from one hospital research center in Istanbul, Turkey. Eligible pregnant women, the majority undergoing elective cesarean delivery (n=106), and the remaining emergency cesarean section cases (n=34), received intracesarean insertion of Gyn-CS or TCu380A insertion. Follow-up ended with a 3 month-visit. The Zeynep Kamil University Hospital Ethics Committee approved this study. The study explores the retention of 140 insertions, 70 Gyn-CS and 70 TCu380A. There were two follow-up visits after discharge from hospital at 6 weeks and 3 months. A single Gyn-CS expulsion occurred after approximately 6 weeks likely a consequence of improper anchoring. Expulsion was more common in the TCu380 A IUD group (11.4% vs 1.4%, p=.039). There were 4 removals for medical reasons in the Gyn-CS patients and 4 in the TCu380A patients, respectively, with 4 non-medical removals occurred, 2 in each group. No serious adverse events (e.g., PID, perforation) were reported. At the study conclusion of 3 months, 61 Gyn-CS (88%) and 54 TCu380A (79%) IUDs remain in place. This immediate postplacental study in cesarean section patients suggests that the anchoring technique employed resulted in the excellent retention of Gyn-CS. Insertion was easy, safe and quick requiring minimal physician training. The possibility of direct visualization of the anchor by ultrasound at insertion and follow-up allows the surgeon to verify the position of the IUD serving to enhance provider and patient confidence and assurance. The frameless anchored intrauterine IUD is effective in minimizing displacement and expulsion. The results of this study suggest that the Gyn-CS IUD is appropriate for wider intracesarean use.</description><identifier>ISSN: 0010-7824</identifier><identifier>EISSN: 1879-0518</identifier><identifier>DOI: 10.1016/j.contraception.2018.03.034</identifier><identifier>PMID: 29678365</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Anchoring technology ; Cesarean section ; Frameless IUD ; IUD expulsion ; Postpartum IUD ; TCu380A</subject><ispartof>Contraception (Stoneham), 2018-08, Vol.98 (2), p.135-140</ispartof><rights>2018 Elsevier Inc.</rights><rights>Copyright © 2018 Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c383t-4c45e591cbed9dc857ac58584271d2ae2f11a0562275db471f6258149d6323793</citedby><cites>FETCH-LOGICAL-c383t-4c45e591cbed9dc857ac58584271d2ae2f11a0562275db471f6258149d6323793</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29678365$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Unal, Ceren</creatorcontrib><creatorcontrib>Eser, Ahmet</creatorcontrib><creatorcontrib>Tozkir, Elif</creatorcontrib><creatorcontrib>Wildemeersch, D.</creatorcontrib><title>Comparison of expulsions following intracesarean placement of an innovative frameless copper-releasing IUD (Gyn-CS®) versus the TCu380A: A randomized trial</title><title>Contraception (Stoneham)</title><addtitle>Contraception</addtitle><description>The intent of this study (primary outcome measure) is to assess the expulsion rate of a newly developed copper releasing frameless intrauterine IUD GyneFix® Cesarean Section (Gyn-CS®) at 3 months' follow-up, compared to the TCu-380A IUD, inserted immediately postplacental expulsion following cesarean section delivery. This is a randomized trial from one hospital research center in Istanbul, Turkey. Eligible pregnant women, the majority undergoing elective cesarean delivery (n=106), and the remaining emergency cesarean section cases (n=34), received intracesarean insertion of Gyn-CS or TCu380A insertion. Follow-up ended with a 3 month-visit. The Zeynep Kamil University Hospital Ethics Committee approved this study. The study explores the retention of 140 insertions, 70 Gyn-CS and 70 TCu380A. There were two follow-up visits after discharge from hospital at 6 weeks and 3 months. A single Gyn-CS expulsion occurred after approximately 6 weeks likely a consequence of improper anchoring. Expulsion was more common in the TCu380 A IUD group (11.4% vs 1.4%, p=.039). There were 4 removals for medical reasons in the Gyn-CS patients and 4 in the TCu380A patients, respectively, with 4 non-medical removals occurred, 2 in each group. No serious adverse events (e.g., PID, perforation) were reported. At the study conclusion of 3 months, 61 Gyn-CS (88%) and 54 TCu380A (79%) IUDs remain in place. This immediate postplacental study in cesarean section patients suggests that the anchoring technique employed resulted in the excellent retention of Gyn-CS. Insertion was easy, safe and quick requiring minimal physician training. The possibility of direct visualization of the anchor by ultrasound at insertion and follow-up allows the surgeon to verify the position of the IUD serving to enhance provider and patient confidence and assurance. The frameless anchored intrauterine IUD is effective in minimizing displacement and expulsion. The results of this study suggest that the Gyn-CS IUD is appropriate for wider intracesarean use.</description><subject>Anchoring technology</subject><subject>Cesarean section</subject><subject>Frameless IUD</subject><subject>IUD expulsion</subject><subject>Postpartum IUD</subject><subject>TCu380A</subject><issn>0010-7824</issn><issn>1879-0518</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqNkcFu1DAQhi1ERZfCKyBLXMohW9uJYwdOq1BKpUocaM-W156AV4kd7GShfZY-Aw_Bk-FoW6TekEaaGemb_9foR-gtJWtKaH22W5vgp6gNjJMLfs0IlWtS5qqeoRWVoikIp_I5WhFCSSEkq47Ry5R2hBDRcPECHbOmFrKs-Qrdt2EYdXQpeBw6DL_GuU9ZNeEu9H346fw37A5uSUfQHo99ngfw08Ln3Xkf9npye8Bd1AP0kBI2YRwhFjFvOi0alzcf8enFrS_ar39-v8N7iGlOePoO-LqdS0k27_EGR-1tGNwdWDxFp_tX6KjTfYLXD_0E3Xw6v24_F1dfLi7bzVVhSllORWUqDryhZgu2sUZyoQ2XXFZMUMs0sI5STXjNmOB2Wwna1YxLWjW2LlkpmvIEnR50xxh-zJAmNbhkoO-1hzAnxQiTTTZgC_rhgJoYUorQqTG6QcdbRYla4lE79SQetcSjSJmrytdvHozm7QD23-1jHhk4PwCQ3907iCoZB96AdRHMpGxw_2X0F8IAq4Q</recordid><startdate>20180801</startdate><enddate>20180801</enddate><creator>Unal, Ceren</creator><creator>Eser, Ahmet</creator><creator>Tozkir, Elif</creator><creator>Wildemeersch, D.</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20180801</creationdate><title>Comparison of expulsions following intracesarean placement of an innovative frameless copper-releasing IUD (Gyn-CS®) versus the TCu380A: A randomized trial</title><author>Unal, Ceren ; Eser, Ahmet ; Tozkir, Elif ; Wildemeersch, D.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c383t-4c45e591cbed9dc857ac58584271d2ae2f11a0562275db471f6258149d6323793</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Anchoring technology</topic><topic>Cesarean section</topic><topic>Frameless IUD</topic><topic>IUD expulsion</topic><topic>Postpartum IUD</topic><topic>TCu380A</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Unal, Ceren</creatorcontrib><creatorcontrib>Eser, Ahmet</creatorcontrib><creatorcontrib>Tozkir, Elif</creatorcontrib><creatorcontrib>Wildemeersch, D.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Contraception (Stoneham)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Unal, Ceren</au><au>Eser, Ahmet</au><au>Tozkir, Elif</au><au>Wildemeersch, D.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of expulsions following intracesarean placement of an innovative frameless copper-releasing IUD (Gyn-CS®) versus the TCu380A: A randomized trial</atitle><jtitle>Contraception (Stoneham)</jtitle><addtitle>Contraception</addtitle><date>2018-08-01</date><risdate>2018</risdate><volume>98</volume><issue>2</issue><spage>135</spage><epage>140</epage><pages>135-140</pages><issn>0010-7824</issn><eissn>1879-0518</eissn><abstract>The intent of this study (primary outcome measure) is to assess the expulsion rate of a newly developed copper releasing frameless intrauterine IUD GyneFix® Cesarean Section (Gyn-CS®) at 3 months' follow-up, compared to the TCu-380A IUD, inserted immediately postplacental expulsion following cesarean section delivery. This is a randomized trial from one hospital research center in Istanbul, Turkey. Eligible pregnant women, the majority undergoing elective cesarean delivery (n=106), and the remaining emergency cesarean section cases (n=34), received intracesarean insertion of Gyn-CS or TCu380A insertion. Follow-up ended with a 3 month-visit. The Zeynep Kamil University Hospital Ethics Committee approved this study. The study explores the retention of 140 insertions, 70 Gyn-CS and 70 TCu380A. There were two follow-up visits after discharge from hospital at 6 weeks and 3 months. A single Gyn-CS expulsion occurred after approximately 6 weeks likely a consequence of improper anchoring. Expulsion was more common in the TCu380 A IUD group (11.4% vs 1.4%, p=.039). There were 4 removals for medical reasons in the Gyn-CS patients and 4 in the TCu380A patients, respectively, with 4 non-medical removals occurred, 2 in each group. No serious adverse events (e.g., PID, perforation) were reported. At the study conclusion of 3 months, 61 Gyn-CS (88%) and 54 TCu380A (79%) IUDs remain in place. This immediate postplacental study in cesarean section patients suggests that the anchoring technique employed resulted in the excellent retention of Gyn-CS. Insertion was easy, safe and quick requiring minimal physician training. The possibility of direct visualization of the anchor by ultrasound at insertion and follow-up allows the surgeon to verify the position of the IUD serving to enhance provider and patient confidence and assurance. The frameless anchored intrauterine IUD is effective in minimizing displacement and expulsion. The results of this study suggest that the Gyn-CS IUD is appropriate for wider intracesarean use.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>29678365</pmid><doi>10.1016/j.contraception.2018.03.034</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0010-7824
ispartof Contraception (Stoneham), 2018-08, Vol.98 (2), p.135-140
issn 0010-7824
1879-0518
language eng
recordid cdi_proquest_miscellaneous_2028959129
source ScienceDirect Freedom Collection 2022-2024
subjects Anchoring technology
Cesarean section
Frameless IUD
IUD expulsion
Postpartum IUD
TCu380A
title Comparison of expulsions following intracesarean placement of an innovative frameless copper-releasing IUD (Gyn-CS®) versus the TCu380A: A randomized trial
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-23T16%3A52%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20expulsions%20following%20intracesarean%20placement%20of%20an%20innovative%20frameless%20copper-releasing%20IUD%20(Gyn-CS%C2%AE)%20versus%20the%20TCu380A:%20A%20randomized%20trial&rft.jtitle=Contraception%20(Stoneham)&rft.au=Unal,%20Ceren&rft.date=2018-08-01&rft.volume=98&rft.issue=2&rft.spage=135&rft.epage=140&rft.pages=135-140&rft.issn=0010-7824&rft.eissn=1879-0518&rft_id=info:doi/10.1016/j.contraception.2018.03.034&rft_dat=%3Cproquest_cross%3E2028959129%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c383t-4c45e591cbed9dc857ac58584271d2ae2f11a0562275db471f6258149d6323793%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2028959129&rft_id=info:pmid/29678365&rfr_iscdi=true