Application of the Bogossian formula for evaluation of the QT interval in pacemaker patients with stimulated left bundle branch block
Background The presence of left bundle branch block (LBBB) represents a particular challenge in properly measuring the QT interval. Here we demonstrate the applicability of the “Bogossian formula” in pacemaker patients with LBBB due to apical or nonapical right ventricular (RV) pacing and preserved...
Saved in:
Published in: | Clinical research in cardiology 2018-11, Vol.107 (11), p.1033-1039 |
---|---|
Main Authors: | , , , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Background
The presence of left bundle branch block (LBBB) represents a particular challenge in properly measuring the QT interval. Here we demonstrate the applicability of the “Bogossian formula” in pacemaker patients with LBBB due to apical or nonapical right ventricular (RV) pacing and preserved left ventricular function.
Methods
A total of 163 patients with a cardiac one- or two-chamber pacemaker were included in this prospective, multicentre observational study. Twelve-lead ECG recordings were obtained during both intrinsic rhythm and RV pacing with induced LBBB. The QT interval measured during LBBB was corrected using the Bogossian formula to obtain the “modified QT” (QTm). The QTmc interval was calculated with the Bazett formula, and this was compared with the QTc interval during intrinsic rhythm.
Results
Eighty-three patients (78 ± 9 years; male
n
= 83) with apical and eighty patients (71 ± 13 years; male
n
= 80) with non-apical RV pacing were included in this study. In the apical group the QTmc was determined to be 444 ± 39 ms in paced rhythm and the QTc interval 413 ± 36 ms in intrinsic rhythm. In the non-apical group these values were 430 ± 34 ms in paced and 416 ± 32 ms in intrinsic rhythm.
Conclusion
The Bogossian formula is a reliable tool for QTc interval evaluation in pacemaker patients with LBBB due to apical or non-apical RV pacing. However, an overestimation of 30 ms should be included in the calculation. |
---|---|
ISSN: | 1861-0684 1861-0692 |
DOI: | 10.1007/s00392-018-1275-6 |