Mechanical aspiration thrombectomy in the treatment of acute intrastent renal artery thrombosis

Chimney-and-periscope technique for thoraco-abdominal aneurysm repair is a valuable treatment option in selected patients. Acute renal artery occlusion is a serious complication after this technique. We report a case of acute right renal artery occlusion, consequent to a previous chimney-and-perisco...

Full description

Saved in:
Bibliographic Details
Published in:Cardiovascular revascularization medicine 2019-04, Vol.20 (4), p.344-346
Main Authors: Rossi, Umberto G., Rollandi, Gian Andrea, Dallatana, Raffaello, Cariati, Maurizio
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Chimney-and-periscope technique for thoraco-abdominal aneurysm repair is a valuable treatment option in selected patients. Acute renal artery occlusion is a serious complication after this technique. We report a case of acute right renal artery occlusion, consequent to a previous chimney-and-periscope technique that was treated urgently by mechanical aspiration thrombectomy. •Acute renal artery thrombosis remains one of the most serious vascular pathology that has to be treated promptly.•Mechanical aspiration thrombectomy is now used in abdominal visceral arteries to solve acute thrombosis.
ISSN:1553-8389
1878-0938
DOI:10.1016/j.carrev.2018.04.009