In reply to: "Intra-aortic balloon pump protects against hydrostatic pulmonary oedema during peripheral venoarterial-extracorporeal membrane oxygenation"

Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is an increasingly utilized life-saving measure. However, left-ventricular distention from inadequate left-ventricular off-loading can lead to unwanted pulmonary and cardiac complications. We are writing to indicate our agreement with a rec...

Full description

Saved in:
Bibliographic Details
Published in:European heart journal. Acute cardiovascular care 2021-03, Vol.10 (1), p.81-82
Main Authors: Privratsky, Jamie R, Diaz, Sebastian, Nicoara, Alina, Daneshmand, Mani A
Format: Article
Language:English
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is an increasingly utilized life-saving measure. However, left-ventricular distention from inadequate left-ventricular off-loading can lead to unwanted pulmonary and cardiac complications. We are writing to indicate our agreement with a recent article by Brechot et al. published in the June 2017 issue where the authors demonstrated that intra-aortic balloon pump provides mechanical support to off-load the left ventricle during VA-ECMO, which prevents pulmonary edema.