Loading…

A new generation of CN sensing silver chalcogenide-selective membranes for FIA application I. Flow-injection detector for CN based on thin Ag2+ delta Se1-xTex electroplated membrane

A new generation of chalcogenide based ion-selective flow-injection detectors (ISFID) for free cyanide has been developed, based on thin film electrodeposited Ag2+ delta Se1-xTex membrane. Detailed performance characterization of the detector has shown that it meets the stringent requirements of mos...

Full description

Saved in:
Bibliographic Details
Published in:Sensors and actuators. B, Chemical Chemical, 2006-12, Vol.119 (2), p.625-631
Main Authors: Neshkova, Milka T, Pancheva, Elka M, Pashova, Veselina
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 631
container_issue 2
container_start_page 625
container_title Sensors and actuators. B, Chemical
container_volume 119
creator Neshkova, Milka T
Pancheva, Elka M
Pashova, Veselina
description A new generation of chalcogenide based ion-selective flow-injection detectors (ISFID) for free cyanide has been developed, based on thin film electrodeposited Ag2+ delta Se1-xTex membrane. Detailed performance characterization of the detector has shown that it meets the stringent requirements of most of the environmental regulatory agencies for toxic cyanide monitoring as far as the observed low detection limit of 75ppb, free cyanide species selectivity and long-term stability are concerned. Moreover, the cost-effective technology for its preparation and easy re-generation makes is attractive candidate for incorporation into automated in-field devices for in situ cyanide monitoring. The renaissance of the dicyanoargentate(I) indicator technique by its successful adapting to flow-injection mode has allowed for further decrease of the lower detection limit down to 15ppb. The complementary usage of both direct and indicator flow-methods opens the way to simple and reliable cyanide speciation in complex effluent matrices.
doi_str_mv 10.1016/j.snb.2006.01.014
format article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_20469513</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>7669154</sourcerecordid><originalsourceid>FETCH-LOGICAL-p186t-11d90c7da71c41a092f2181184a020fec9946bcd4473bc9dcb082a24fe12a1263</originalsourceid><addsrcrecordid>eNo1kMFOwzAMhnMAiTF4AG4-cUEtTpp17XGaGEya4MA4T2nqbpmypDRl24vxfmQMJEu2fn_6f8uM3XFMOfL8cZsGV6UCMU-Rx5IXbIClGCUScXTFrkPYIqLMchyw7wk4OsCaHHWqN96Bb2D6CoFcMG4Nwdg9daA3ymofKVNTEsiS7s2eYEe7qlOOAjS-g9l8AqptrdFnp3kKM-sPiXHbEx-Vmvo4RfSEx5RKBaohLvqNcTBZi4eI2F7BO_HkuKQj_EZ1vrWqj-R_3g27bJQNdPvXh-xj9rScviSLt-f5dLJIWl7kfcJ5XaIe12rMteQq_qARvOC8kAoFNqTLUuaVrqUcZ5Uua11hIZSQDXGhuMizIbs_-7ad__yi0K92JmiyNt7gv8JKoMzLEc-yH2LsdN8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>20469513</pqid></control><display><type>article</type><title>A new generation of CN sensing silver chalcogenide-selective membranes for FIA application I. Flow-injection detector for CN based on thin Ag2+ delta Se1-xTex electroplated membrane</title><source>ScienceDirect Freedom Collection</source><creator>Neshkova, Milka T ; Pancheva, Elka M ; Pashova, Veselina</creator><creatorcontrib>Neshkova, Milka T ; Pancheva, Elka M ; Pashova, Veselina</creatorcontrib><description>A new generation of chalcogenide based ion-selective flow-injection detectors (ISFID) for free cyanide has been developed, based on thin film electrodeposited Ag2+ delta Se1-xTex membrane. Detailed performance characterization of the detector has shown that it meets the stringent requirements of most of the environmental regulatory agencies for toxic cyanide monitoring as far as the observed low detection limit of 75ppb, free cyanide species selectivity and long-term stability are concerned. Moreover, the cost-effective technology for its preparation and easy re-generation makes is attractive candidate for incorporation into automated in-field devices for in situ cyanide monitoring. The renaissance of the dicyanoargentate(I) indicator technique by its successful adapting to flow-injection mode has allowed for further decrease of the lower detection limit down to 15ppb. The complementary usage of both direct and indicator flow-methods opens the way to simple and reliable cyanide speciation in complex effluent matrices.</description><identifier>ISSN: 0925-4005</identifier><identifier>DOI: 10.1016/j.snb.2006.01.014</identifier><language>eng</language><subject>Economics ; Environmental regulations ; Q1 ; Sensors ; Technology ; Toxic materials</subject><ispartof>Sensors and actuators. B, Chemical, 2006-12, Vol.119 (2), p.625-631</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Neshkova, Milka T</creatorcontrib><creatorcontrib>Pancheva, Elka M</creatorcontrib><creatorcontrib>Pashova, Veselina</creatorcontrib><title>A new generation of CN sensing silver chalcogenide-selective membranes for FIA application I. Flow-injection detector for CN based on thin Ag2+ delta Se1-xTex electroplated membrane</title><title>Sensors and actuators. B, Chemical</title><description>A new generation of chalcogenide based ion-selective flow-injection detectors (ISFID) for free cyanide has been developed, based on thin film electrodeposited Ag2+ delta Se1-xTex membrane. Detailed performance characterization of the detector has shown that it meets the stringent requirements of most of the environmental regulatory agencies for toxic cyanide monitoring as far as the observed low detection limit of 75ppb, free cyanide species selectivity and long-term stability are concerned. Moreover, the cost-effective technology for its preparation and easy re-generation makes is attractive candidate for incorporation into automated in-field devices for in situ cyanide monitoring. The renaissance of the dicyanoargentate(I) indicator technique by its successful adapting to flow-injection mode has allowed for further decrease of the lower detection limit down to 15ppb. The complementary usage of both direct and indicator flow-methods opens the way to simple and reliable cyanide speciation in complex effluent matrices.</description><subject>Economics</subject><subject>Environmental regulations</subject><subject>Q1</subject><subject>Sensors</subject><subject>Technology</subject><subject>Toxic materials</subject><issn>0925-4005</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNo1kMFOwzAMhnMAiTF4AG4-cUEtTpp17XGaGEya4MA4T2nqbpmypDRl24vxfmQMJEu2fn_6f8uM3XFMOfL8cZsGV6UCMU-Rx5IXbIClGCUScXTFrkPYIqLMchyw7wk4OsCaHHWqN96Bb2D6CoFcMG4Nwdg9daA3ymofKVNTEsiS7s2eYEe7qlOOAjS-g9l8AqptrdFnp3kKM-sPiXHbEx-Vmvo4RfSEx5RKBaohLvqNcTBZi4eI2F7BO_HkuKQj_EZ1vrWqj-R_3g27bJQNdPvXh-xj9rScviSLt-f5dLJIWl7kfcJ5XaIe12rMteQq_qARvOC8kAoFNqTLUuaVrqUcZ5Uua11hIZSQDXGhuMizIbs_-7ad__yi0K92JmiyNt7gv8JKoMzLEc-yH2LsdN8</recordid><startdate>20061207</startdate><enddate>20061207</enddate><creator>Neshkova, Milka T</creator><creator>Pancheva, Elka M</creator><creator>Pashova, Veselina</creator><scope/></search><sort><creationdate>20061207</creationdate><title>A new generation of CN sensing silver chalcogenide-selective membranes for FIA application I. Flow-injection detector for CN based on thin Ag2+ delta Se1-xTex electroplated membrane</title><author>Neshkova, Milka T ; Pancheva, Elka M ; Pashova, Veselina</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p186t-11d90c7da71c41a092f2181184a020fec9946bcd4473bc9dcb082a24fe12a1263</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Economics</topic><topic>Environmental regulations</topic><topic>Q1</topic><topic>Sensors</topic><topic>Technology</topic><topic>Toxic materials</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Neshkova, Milka T</creatorcontrib><creatorcontrib>Pancheva, Elka M</creatorcontrib><creatorcontrib>Pashova, Veselina</creatorcontrib><jtitle>Sensors and actuators. B, Chemical</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Neshkova, Milka T</au><au>Pancheva, Elka M</au><au>Pashova, Veselina</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A new generation of CN sensing silver chalcogenide-selective membranes for FIA application I. Flow-injection detector for CN based on thin Ag2+ delta Se1-xTex electroplated membrane</atitle><jtitle>Sensors and actuators. B, Chemical</jtitle><date>2006-12-07</date><risdate>2006</risdate><volume>119</volume><issue>2</issue><spage>625</spage><epage>631</epage><pages>625-631</pages><issn>0925-4005</issn><abstract>A new generation of chalcogenide based ion-selective flow-injection detectors (ISFID) for free cyanide has been developed, based on thin film electrodeposited Ag2+ delta Se1-xTex membrane. Detailed performance characterization of the detector has shown that it meets the stringent requirements of most of the environmental regulatory agencies for toxic cyanide monitoring as far as the observed low detection limit of 75ppb, free cyanide species selectivity and long-term stability are concerned. Moreover, the cost-effective technology for its preparation and easy re-generation makes is attractive candidate for incorporation into automated in-field devices for in situ cyanide monitoring. The renaissance of the dicyanoargentate(I) indicator technique by its successful adapting to flow-injection mode has allowed for further decrease of the lower detection limit down to 15ppb. The complementary usage of both direct and indicator flow-methods opens the way to simple and reliable cyanide speciation in complex effluent matrices.</abstract><doi>10.1016/j.snb.2006.01.014</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0925-4005
ispartof Sensors and actuators. B, Chemical, 2006-12, Vol.119 (2), p.625-631
issn 0925-4005
language eng
recordid cdi_proquest_miscellaneous_20469513
source ScienceDirect Freedom Collection
subjects Economics
Environmental regulations
Q1
Sensors
Technology
Toxic materials
title A new generation of CN sensing silver chalcogenide-selective membranes for FIA application I. Flow-injection detector for CN based on thin Ag2+ delta Se1-xTex electroplated membrane
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T03%3A12%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20new%20generation%20of%20CN%20sensing%20silver%20chalcogenide-selective%20membranes%20for%20FIA%20application%20I.%20Flow-injection%20detector%20for%20CN%20based%20on%20thin%20Ag2+%20delta%20Se1-xTex%20electroplated%20membrane&rft.jtitle=Sensors%20and%20actuators.%20B,%20Chemical&rft.au=Neshkova,%20Milka%20T&rft.date=2006-12-07&rft.volume=119&rft.issue=2&rft.spage=625&rft.epage=631&rft.pages=625-631&rft.issn=0925-4005&rft_id=info:doi/10.1016/j.snb.2006.01.014&rft_dat=%3Cproquest%3E7669154%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-p186t-11d90c7da71c41a092f2181184a020fec9946bcd4473bc9dcb082a24fe12a1263%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=20469513&rft_id=info:pmid/&rfr_iscdi=true