Loading…

A Monte Carlo Interstitial Brachytherapy Study for AAPM TG-43 Dose Calculation Formalism in Heterogeneous Media

The precision of AAPM TG-43 dose calculation formalism in heterogeneous media has been studied based on the survey and evaluation of the status of interstitial brachytherapy. After a brief introduction of radioactive seeds ( 125 I, 192 Ir and 103 Pd) and AAPM TG-43 formalism, the radial dose rates c...

Full description

Saved in:
Bibliographic Details
Main Authors: Gang Song, Wu, Y.
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The precision of AAPM TG-43 dose calculation formalism in heterogeneous media has been studied based on the survey and evaluation of the status of interstitial brachytherapy. After a brief introduction of radioactive seeds ( 125 I, 192 Ir and 103 Pd) and AAPM TG-43 formalism, the radial dose rates calculated by Monte Carlo code MCNP-4C and TG-43 formalism were compared with homogeneous and heterogeneous phantoms. The reason of errors between the results of the above two methods was analyzed, and modified dose rates constant were proposed and testified. With the updated dose rates constant, AAPM TG-43 formalism can predict the dose rate distribution accurately and rapidly in clinical.
ISSN:2151-7614
2151-7622
DOI:10.1109/ICBBE.2008.246