Loading…

Effective scale control for seawater RO operating with high feed water pH and temperature

An effective scale control program for seawater RO is widely recognized as an important factor in ensuring trouble free and cost effective operation. This is especially important under the high feed water pH and temperature conditions found in Southern Europe and Middle East. In addition, regulatory...

Full description

Saved in:
Bibliographic Details
Published in:Desalination 2008-03, Vol.220 (1-3), p.295-304
Main Authors: Andrews, Brett, Davé, Bhasker, López-Serrano, Paloma, Tsai, Shih-Perng, Frank, Rich, Wilf, Mark, Koutsakos, Erineos
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c395t-cf800c60400a7742a546bbbf44300ee80e42bc32225449efca4b92765944d91f3
cites cdi_FETCH-LOGICAL-c395t-cf800c60400a7742a546bbbf44300ee80e42bc32225449efca4b92765944d91f3
container_end_page 304
container_issue 1-3
container_start_page 295
container_title Desalination
container_volume 220
creator Andrews, Brett
Davé, Bhasker
López-Serrano, Paloma
Tsai, Shih-Perng
Frank, Rich
Wilf, Mark
Koutsakos, Erineos
description An effective scale control program for seawater RO is widely recognized as an important factor in ensuring trouble free and cost effective operation. This is especially important under the high feed water pH and temperature conditions found in Southern Europe and Middle East. In addition, regulatory issues concerning maximum acceptable boron levels in drinking and irrigation water necessitate the growing need to operate plants at higher feed water pH. Operating at increased pH increases boron rejection but also increases the scaling tendencies of the water. This can lead to calcium carbonate and magnesium hydroxide precipitation in the membranes. A complete scale control program needs to control calcite and brucite saturation at the maximum operating reject pH and temperature. Antiscalant chemistry, optimum dose rate as well as accurate monitoring and control of the scale inhibitor are key factors in long-term cost effective “scale free” operation. This paper details the operating strategies and scale control issues related to both single and two pass seawater RO plants operating at elevated feed water pH and temperature.
doi_str_mv 10.1016/j.desal.2007.02.041
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_20816777</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0011916407006273</els_id><sourcerecordid>20816777</sourcerecordid><originalsourceid>FETCH-LOGICAL-c395t-cf800c60400a7742a546bbbf44300ee80e42bc32225449efca4b92765944d91f3</originalsourceid><addsrcrecordid>eNqFkbFu2zAQhomgBeK6eYIsXJpN6pE6ieLQITDSOICBAEUzZCIo6mjTkCWXlG307SvHQcd2Ohzw_f8B3zF2KyAXIKqv27ylZLtcAqgcZA4orthM1KrIECv8wGYAQmRaVHjNPqW0nVapi2LGXh-8JzeGI_HkbEfcDf0Yh477IfJE9mRHivzHMx_2FO0Y-jU_hXHDN2G94Z6o5Rdiv-S2b_lIuzfuEOkz--htl-jmfc7Zy_eHn4tltnp-fFrcrzJX6HLMnK8BXAUIYJVCaUusmqbxiAUAUQ2EsnGFlLJE1OSdxUZLVZUasdXCF3N2d-ndx-HXgdJodiE56jrb03BIRkItKqXUf0GBdaW0xAksLqCLQ0qRvNnHsLPxtxFgzr7N1rz5NmffBqSZfE-pL-_19mzSR9u7kP5GJUhdSlFO3LcLR5OUY6BokgvUO2pDnD5h2iH8884fzs-WQA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>14867924</pqid></control><display><type>article</type><title>Effective scale control for seawater RO operating with high feed water pH and temperature</title><source>Elsevier</source><creator>Andrews, Brett ; Davé, Bhasker ; López-Serrano, Paloma ; Tsai, Shih-Perng ; Frank, Rich ; Wilf, Mark ; Koutsakos, Erineos</creator><creatorcontrib>Andrews, Brett ; Davé, Bhasker ; López-Serrano, Paloma ; Tsai, Shih-Perng ; Frank, Rich ; Wilf, Mark ; Koutsakos, Erineos</creatorcontrib><description>An effective scale control program for seawater RO is widely recognized as an important factor in ensuring trouble free and cost effective operation. This is especially important under the high feed water pH and temperature conditions found in Southern Europe and Middle East. In addition, regulatory issues concerning maximum acceptable boron levels in drinking and irrigation water necessitate the growing need to operate plants at higher feed water pH. Operating at increased pH increases boron rejection but also increases the scaling tendencies of the water. This can lead to calcium carbonate and magnesium hydroxide precipitation in the membranes. A complete scale control program needs to control calcite and brucite saturation at the maximum operating reject pH and temperature. Antiscalant chemistry, optimum dose rate as well as accurate monitoring and control of the scale inhibitor are key factors in long-term cost effective “scale free” operation. This paper details the operating strategies and scale control issues related to both single and two pass seawater RO plants operating at elevated feed water pH and temperature.</description><identifier>ISSN: 0011-9164</identifier><identifier>EISSN: 1873-4464</identifier><identifier>DOI: 10.1016/j.desal.2007.02.041</identifier><identifier>CODEN: DSLNAH</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Applied sciences ; Exact sciences and technology ; Marine ; Natural water pollution ; Pollution ; Seawaters, estuaries ; Water treatment and pollution</subject><ispartof>Desalination, 2008-03, Vol.220 (1-3), p.295-304</ispartof><rights>2008</rights><rights>2008 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c395t-cf800c60400a7742a546bbbf44300ee80e42bc32225449efca4b92765944d91f3</citedby><cites>FETCH-LOGICAL-c395t-cf800c60400a7742a546bbbf44300ee80e42bc32225449efca4b92765944d91f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,314,776,780,785,786,23910,23911,25119,27903,27904</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=20295215$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Andrews, Brett</creatorcontrib><creatorcontrib>Davé, Bhasker</creatorcontrib><creatorcontrib>López-Serrano, Paloma</creatorcontrib><creatorcontrib>Tsai, Shih-Perng</creatorcontrib><creatorcontrib>Frank, Rich</creatorcontrib><creatorcontrib>Wilf, Mark</creatorcontrib><creatorcontrib>Koutsakos, Erineos</creatorcontrib><title>Effective scale control for seawater RO operating with high feed water pH and temperature</title><title>Desalination</title><description>An effective scale control program for seawater RO is widely recognized as an important factor in ensuring trouble free and cost effective operation. This is especially important under the high feed water pH and temperature conditions found in Southern Europe and Middle East. In addition, regulatory issues concerning maximum acceptable boron levels in drinking and irrigation water necessitate the growing need to operate plants at higher feed water pH. Operating at increased pH increases boron rejection but also increases the scaling tendencies of the water. This can lead to calcium carbonate and magnesium hydroxide precipitation in the membranes. A complete scale control program needs to control calcite and brucite saturation at the maximum operating reject pH and temperature. Antiscalant chemistry, optimum dose rate as well as accurate monitoring and control of the scale inhibitor are key factors in long-term cost effective “scale free” operation. This paper details the operating strategies and scale control issues related to both single and two pass seawater RO plants operating at elevated feed water pH and temperature.</description><subject>Applied sciences</subject><subject>Exact sciences and technology</subject><subject>Marine</subject><subject>Natural water pollution</subject><subject>Pollution</subject><subject>Seawaters, estuaries</subject><subject>Water treatment and pollution</subject><issn>0011-9164</issn><issn>1873-4464</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNqFkbFu2zAQhomgBeK6eYIsXJpN6pE6ieLQITDSOICBAEUzZCIo6mjTkCWXlG307SvHQcd2Ohzw_f8B3zF2KyAXIKqv27ylZLtcAqgcZA4orthM1KrIECv8wGYAQmRaVHjNPqW0nVapi2LGXh-8JzeGI_HkbEfcDf0Yh477IfJE9mRHivzHMx_2FO0Y-jU_hXHDN2G94Z6o5Rdiv-S2b_lIuzfuEOkz--htl-jmfc7Zy_eHn4tltnp-fFrcrzJX6HLMnK8BXAUIYJVCaUusmqbxiAUAUQ2EsnGFlLJE1OSdxUZLVZUasdXCF3N2d-ndx-HXgdJodiE56jrb03BIRkItKqXUf0GBdaW0xAksLqCLQ0qRvNnHsLPxtxFgzr7N1rz5NmffBqSZfE-pL-_19mzSR9u7kP5GJUhdSlFO3LcLR5OUY6BokgvUO2pDnD5h2iH8884fzs-WQA</recordid><startdate>20080301</startdate><enddate>20080301</enddate><creator>Andrews, Brett</creator><creator>Davé, Bhasker</creator><creator>López-Serrano, Paloma</creator><creator>Tsai, Shih-Perng</creator><creator>Frank, Rich</creator><creator>Wilf, Mark</creator><creator>Koutsakos, Erineos</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope><scope>7TN</scope><scope>7UA</scope><scope>F1W</scope><scope>H96</scope><scope>L.G</scope></search><sort><creationdate>20080301</creationdate><title>Effective scale control for seawater RO operating with high feed water pH and temperature</title><author>Andrews, Brett ; Davé, Bhasker ; López-Serrano, Paloma ; Tsai, Shih-Perng ; Frank, Rich ; Wilf, Mark ; Koutsakos, Erineos</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c395t-cf800c60400a7742a546bbbf44300ee80e42bc32225449efca4b92765944d91f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Applied sciences</topic><topic>Exact sciences and technology</topic><topic>Marine</topic><topic>Natural water pollution</topic><topic>Pollution</topic><topic>Seawaters, estuaries</topic><topic>Water treatment and pollution</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Andrews, Brett</creatorcontrib><creatorcontrib>Davé, Bhasker</creatorcontrib><creatorcontrib>López-Serrano, Paloma</creatorcontrib><creatorcontrib>Tsai, Shih-Perng</creatorcontrib><creatorcontrib>Frank, Rich</creatorcontrib><creatorcontrib>Wilf, Mark</creatorcontrib><creatorcontrib>Koutsakos, Erineos</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><collection>Oceanic Abstracts</collection><collection>Water Resources Abstracts</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) 2: Ocean Technology, Policy &amp; Non-Living Resources</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) Professional</collection><jtitle>Desalination</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Andrews, Brett</au><au>Davé, Bhasker</au><au>López-Serrano, Paloma</au><au>Tsai, Shih-Perng</au><au>Frank, Rich</au><au>Wilf, Mark</au><au>Koutsakos, Erineos</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effective scale control for seawater RO operating with high feed water pH and temperature</atitle><jtitle>Desalination</jtitle><date>2008-03-01</date><risdate>2008</risdate><volume>220</volume><issue>1-3</issue><spage>295</spage><epage>304</epage><pages>295-304</pages><issn>0011-9164</issn><eissn>1873-4464</eissn><coden>DSLNAH</coden><abstract>An effective scale control program for seawater RO is widely recognized as an important factor in ensuring trouble free and cost effective operation. This is especially important under the high feed water pH and temperature conditions found in Southern Europe and Middle East. In addition, regulatory issues concerning maximum acceptable boron levels in drinking and irrigation water necessitate the growing need to operate plants at higher feed water pH. Operating at increased pH increases boron rejection but also increases the scaling tendencies of the water. This can lead to calcium carbonate and magnesium hydroxide precipitation in the membranes. A complete scale control program needs to control calcite and brucite saturation at the maximum operating reject pH and temperature. Antiscalant chemistry, optimum dose rate as well as accurate monitoring and control of the scale inhibitor are key factors in long-term cost effective “scale free” operation. This paper details the operating strategies and scale control issues related to both single and two pass seawater RO plants operating at elevated feed water pH and temperature.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><doi>10.1016/j.desal.2007.02.041</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0011-9164
ispartof Desalination, 2008-03, Vol.220 (1-3), p.295-304
issn 0011-9164
1873-4464
language eng
recordid cdi_proquest_miscellaneous_20816777
source Elsevier
subjects Applied sciences
Exact sciences and technology
Marine
Natural water pollution
Pollution
Seawaters, estuaries
Water treatment and pollution
title Effective scale control for seawater RO operating with high feed water pH and temperature
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T20%3A21%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effective%20scale%20control%20for%20seawater%20RO%20operating%20with%20high%20feed%20water%20pH%20and%20temperature&rft.jtitle=Desalination&rft.au=Andrews,%20Brett&rft.date=2008-03-01&rft.volume=220&rft.issue=1-3&rft.spage=295&rft.epage=304&rft.pages=295-304&rft.issn=0011-9164&rft.eissn=1873-4464&rft.coden=DSLNAH&rft_id=info:doi/10.1016/j.desal.2007.02.041&rft_dat=%3Cproquest_cross%3E20816777%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c395t-cf800c60400a7742a546bbbf44300ee80e42bc32225449efca4b92765944d91f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=14867924&rft_id=info:pmid/&rfr_iscdi=true