Loading…

Comparison of X-ray fluoroscopy and interventional magnetic resonance imaging for the assessment of coronary artery stenoses in swine

The accuracy of a two‐step interventional MRI protocol to quantify coronary artery disease was compared to the clinical gold standard, X‐ray angiography. Studies were conducted in nine swine with a surgically induced stenosis in the proximal left circumflex coronary artery. The two‐step protocol con...

Full description

Saved in:
Bibliographic Details
Published in:Magnetic resonance in medicine 2005-11, Vol.54 (5), p.1094-1099
Main Authors: Green, Jordin D., Omary, Reed A., Schirf, Brian E., Tang, Richard, Lu, Biao, Gehl, James A., Huang, J. Jenny, Carr, James C., Pereles, F. Scott, Li, Debiao
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c3969-6bd4283cbe0b6ecc030f75ff6d17b3b43fa98c07d8a4066a6549bd31278c8fb43
cites cdi_FETCH-LOGICAL-c3969-6bd4283cbe0b6ecc030f75ff6d17b3b43fa98c07d8a4066a6549bd31278c8fb43
container_end_page 1099
container_issue 5
container_start_page 1094
container_title Magnetic resonance in medicine
container_volume 54
creator Green, Jordin D.
Omary, Reed A.
Schirf, Brian E.
Tang, Richard
Lu, Biao
Gehl, James A.
Huang, J. Jenny
Carr, James C.
Pereles, F. Scott
Li, Debiao
description The accuracy of a two‐step interventional MRI protocol to quantify coronary artery disease was compared to the clinical gold standard, X‐ray angiography. Studies were conducted in nine swine with a surgically induced stenosis in the proximal left circumflex coronary artery. The two‐step protocol consisted of catheter‐directed magnetic resonance angiography (MRA), which was first used to localize the stenosis, followed by MRI cross‐sectional images to quantify the degree of stenosis without the use of contrast agent. Line signal intensity profiles were drawn across the vessel diameter at the stenosis site and proximal to the stenosis for each data set to measure percentage stenosis for each animal. Catheter‐directed MRA successfully detected eight of nine stenoses. Cross‐sectional MRI accurately quantified each stenosis, with strong agreement to the measurements made using X‐ray fluoroscopy (intraclass correlation coefficient = 0.955; P < 0.05). This study demonstrates that in the future interventional MRI may be an alternative to X‐ray angiography for the detection and quantification of coronary artery disease. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.
doi_str_mv 10.1002/mrm.20699
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_20856945</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>20856945</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3969-6bd4283cbe0b6ecc030f75ff6d17b3b43fa98c07d8a4066a6549bd31278c8fb43</originalsourceid><addsrcrecordid>eNp1kE1vFCEch4nR2LV68AsYTiYepuVtYDiarVbN1rdo9EYY5k9FZ2ALs9b5AH5vqbvqyRMJPL8n4UHoISUnlBB2OuXphBGp9S20oi1jDWu1uI1WRAnScKrFEbpXyldCiNZK3EVHVDKqVCdW6Oc6TVubQ0kRJ48_N9ku2I-7lFNxabtgGwcc4gz5O8Q5pGhHPNnLCHNwOEOd2egAh3oX4iX2KeP5C2BbCpQy1cmN1VVbtLnKchUtuMwQUwWqGJfrEOE-uuPtWODB4TxGH58_-7B-0WzenL9cP900jmupG9kPgnXc9UB6Cc4RTrxqvZcDVT3vBfdWd46oobOCSGllK3Q_cMpU5zpf34_R4713m9PVDspsplAcjKONkHbFMNK1Uou2gk_2oKsdSgZvtrn-MS-GEnPT3NTm5nfzyj46SHf9BMM_8hC5Aqd74DqMsPzfZC7eX_xRNvtFqKl-_F3Y_M1IxVVrPr0-N5u33ebs7NXavOO_APKenmM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>20856945</pqid></control><display><type>article</type><title>Comparison of X-ray fluoroscopy and interventional magnetic resonance imaging for the assessment of coronary artery stenoses in swine</title><source>Wiley</source><creator>Green, Jordin D. ; Omary, Reed A. ; Schirf, Brian E. ; Tang, Richard ; Lu, Biao ; Gehl, James A. ; Huang, J. Jenny ; Carr, James C. ; Pereles, F. Scott ; Li, Debiao</creator><creatorcontrib>Green, Jordin D. ; Omary, Reed A. ; Schirf, Brian E. ; Tang, Richard ; Lu, Biao ; Gehl, James A. ; Huang, J. Jenny ; Carr, James C. ; Pereles, F. Scott ; Li, Debiao</creatorcontrib><description>The accuracy of a two‐step interventional MRI protocol to quantify coronary artery disease was compared to the clinical gold standard, X‐ray angiography. Studies were conducted in nine swine with a surgically induced stenosis in the proximal left circumflex coronary artery. The two‐step protocol consisted of catheter‐directed magnetic resonance angiography (MRA), which was first used to localize the stenosis, followed by MRI cross‐sectional images to quantify the degree of stenosis without the use of contrast agent. Line signal intensity profiles were drawn across the vessel diameter at the stenosis site and proximal to the stenosis for each data set to measure percentage stenosis for each animal. Catheter‐directed MRA successfully detected eight of nine stenoses. Cross‐sectional MRI accurately quantified each stenosis, with strong agreement to the measurements made using X‐ray fluoroscopy (intraclass correlation coefficient = 0.955; P &lt; 0.05). This study demonstrates that in the future interventional MRI may be an alternative to X‐ray angiography for the detection and quantification of coronary artery disease. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.</description><identifier>ISSN: 0740-3194</identifier><identifier>EISSN: 1522-2594</identifier><identifier>DOI: 10.1002/mrm.20699</identifier><identifier>PMID: 16217784</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>Angiography - methods ; Animals ; Cardiac Catheterization - methods ; catheter-directed MR angiography ; comparative studies ; coronary angiography ; Coronary Stenosis - diagnostic imaging ; Coronary Stenosis - pathology ; fluoroscopy ; Fluoroscopy - methods ; interventional MR ; Magnetic Resonance Angiography - methods ; Reproducibility of Results ; Sensitivity and Specificity ; Swine</subject><ispartof>Magnetic resonance in medicine, 2005-11, Vol.54 (5), p.1094-1099</ispartof><rights>Copyright © 2005 Wiley‐Liss, Inc.</rights><rights>(c) 2005 Wiley-Liss, Inc.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3969-6bd4283cbe0b6ecc030f75ff6d17b3b43fa98c07d8a4066a6549bd31278c8fb43</citedby><cites>FETCH-LOGICAL-c3969-6bd4283cbe0b6ecc030f75ff6d17b3b43fa98c07d8a4066a6549bd31278c8fb43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16217784$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Green, Jordin D.</creatorcontrib><creatorcontrib>Omary, Reed A.</creatorcontrib><creatorcontrib>Schirf, Brian E.</creatorcontrib><creatorcontrib>Tang, Richard</creatorcontrib><creatorcontrib>Lu, Biao</creatorcontrib><creatorcontrib>Gehl, James A.</creatorcontrib><creatorcontrib>Huang, J. Jenny</creatorcontrib><creatorcontrib>Carr, James C.</creatorcontrib><creatorcontrib>Pereles, F. Scott</creatorcontrib><creatorcontrib>Li, Debiao</creatorcontrib><title>Comparison of X-ray fluoroscopy and interventional magnetic resonance imaging for the assessment of coronary artery stenoses in swine</title><title>Magnetic resonance in medicine</title><addtitle>Magn. Reson. Med</addtitle><description>The accuracy of a two‐step interventional MRI protocol to quantify coronary artery disease was compared to the clinical gold standard, X‐ray angiography. Studies were conducted in nine swine with a surgically induced stenosis in the proximal left circumflex coronary artery. The two‐step protocol consisted of catheter‐directed magnetic resonance angiography (MRA), which was first used to localize the stenosis, followed by MRI cross‐sectional images to quantify the degree of stenosis without the use of contrast agent. Line signal intensity profiles were drawn across the vessel diameter at the stenosis site and proximal to the stenosis for each data set to measure percentage stenosis for each animal. Catheter‐directed MRA successfully detected eight of nine stenoses. Cross‐sectional MRI accurately quantified each stenosis, with strong agreement to the measurements made using X‐ray fluoroscopy (intraclass correlation coefficient = 0.955; P &lt; 0.05). This study demonstrates that in the future interventional MRI may be an alternative to X‐ray angiography for the detection and quantification of coronary artery disease. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.</description><subject>Angiography - methods</subject><subject>Animals</subject><subject>Cardiac Catheterization - methods</subject><subject>catheter-directed MR angiography</subject><subject>comparative studies</subject><subject>coronary angiography</subject><subject>Coronary Stenosis - diagnostic imaging</subject><subject>Coronary Stenosis - pathology</subject><subject>fluoroscopy</subject><subject>Fluoroscopy - methods</subject><subject>interventional MR</subject><subject>Magnetic Resonance Angiography - methods</subject><subject>Reproducibility of Results</subject><subject>Sensitivity and Specificity</subject><subject>Swine</subject><issn>0740-3194</issn><issn>1522-2594</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNp1kE1vFCEch4nR2LV68AsYTiYepuVtYDiarVbN1rdo9EYY5k9FZ2ALs9b5AH5vqbvqyRMJPL8n4UHoISUnlBB2OuXphBGp9S20oi1jDWu1uI1WRAnScKrFEbpXyldCiNZK3EVHVDKqVCdW6Oc6TVubQ0kRJ48_N9ku2I-7lFNxabtgGwcc4gz5O8Q5pGhHPNnLCHNwOEOd2egAh3oX4iX2KeP5C2BbCpQy1cmN1VVbtLnKchUtuMwQUwWqGJfrEOE-uuPtWODB4TxGH58_-7B-0WzenL9cP900jmupG9kPgnXc9UB6Cc4RTrxqvZcDVT3vBfdWd46oobOCSGllK3Q_cMpU5zpf34_R4713m9PVDspsplAcjKONkHbFMNK1Uou2gk_2oKsdSgZvtrn-MS-GEnPT3NTm5nfzyj46SHf9BMM_8hC5Aqd74DqMsPzfZC7eX_xRNvtFqKl-_F3Y_M1IxVVrPr0-N5u33ebs7NXavOO_APKenmM</recordid><startdate>200511</startdate><enddate>200511</enddate><creator>Green, Jordin D.</creator><creator>Omary, Reed A.</creator><creator>Schirf, Brian E.</creator><creator>Tang, Richard</creator><creator>Lu, Biao</creator><creator>Gehl, James A.</creator><creator>Huang, J. Jenny</creator><creator>Carr, James C.</creator><creator>Pereles, F. Scott</creator><creator>Li, Debiao</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope></search><sort><creationdate>200511</creationdate><title>Comparison of X-ray fluoroscopy and interventional magnetic resonance imaging for the assessment of coronary artery stenoses in swine</title><author>Green, Jordin D. ; Omary, Reed A. ; Schirf, Brian E. ; Tang, Richard ; Lu, Biao ; Gehl, James A. ; Huang, J. Jenny ; Carr, James C. ; Pereles, F. Scott ; Li, Debiao</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3969-6bd4283cbe0b6ecc030f75ff6d17b3b43fa98c07d8a4066a6549bd31278c8fb43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Angiography - methods</topic><topic>Animals</topic><topic>Cardiac Catheterization - methods</topic><topic>catheter-directed MR angiography</topic><topic>comparative studies</topic><topic>coronary angiography</topic><topic>Coronary Stenosis - diagnostic imaging</topic><topic>Coronary Stenosis - pathology</topic><topic>fluoroscopy</topic><topic>Fluoroscopy - methods</topic><topic>interventional MR</topic><topic>Magnetic Resonance Angiography - methods</topic><topic>Reproducibility of Results</topic><topic>Sensitivity and Specificity</topic><topic>Swine</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Green, Jordin D.</creatorcontrib><creatorcontrib>Omary, Reed A.</creatorcontrib><creatorcontrib>Schirf, Brian E.</creatorcontrib><creatorcontrib>Tang, Richard</creatorcontrib><creatorcontrib>Lu, Biao</creatorcontrib><creatorcontrib>Gehl, James A.</creatorcontrib><creatorcontrib>Huang, J. Jenny</creatorcontrib><creatorcontrib>Carr, James C.</creatorcontrib><creatorcontrib>Pereles, F. Scott</creatorcontrib><creatorcontrib>Li, Debiao</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Magnetic resonance in medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Green, Jordin D.</au><au>Omary, Reed A.</au><au>Schirf, Brian E.</au><au>Tang, Richard</au><au>Lu, Biao</au><au>Gehl, James A.</au><au>Huang, J. Jenny</au><au>Carr, James C.</au><au>Pereles, F. Scott</au><au>Li, Debiao</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of X-ray fluoroscopy and interventional magnetic resonance imaging for the assessment of coronary artery stenoses in swine</atitle><jtitle>Magnetic resonance in medicine</jtitle><addtitle>Magn. Reson. Med</addtitle><date>2005-11</date><risdate>2005</risdate><volume>54</volume><issue>5</issue><spage>1094</spage><epage>1099</epage><pages>1094-1099</pages><issn>0740-3194</issn><eissn>1522-2594</eissn><abstract>The accuracy of a two‐step interventional MRI protocol to quantify coronary artery disease was compared to the clinical gold standard, X‐ray angiography. Studies were conducted in nine swine with a surgically induced stenosis in the proximal left circumflex coronary artery. The two‐step protocol consisted of catheter‐directed magnetic resonance angiography (MRA), which was first used to localize the stenosis, followed by MRI cross‐sectional images to quantify the degree of stenosis without the use of contrast agent. Line signal intensity profiles were drawn across the vessel diameter at the stenosis site and proximal to the stenosis for each data set to measure percentage stenosis for each animal. Catheter‐directed MRA successfully detected eight of nine stenoses. Cross‐sectional MRI accurately quantified each stenosis, with strong agreement to the measurements made using X‐ray fluoroscopy (intraclass correlation coefficient = 0.955; P &lt; 0.05). This study demonstrates that in the future interventional MRI may be an alternative to X‐ray angiography for the detection and quantification of coronary artery disease. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><pmid>16217784</pmid><doi>10.1002/mrm.20699</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0740-3194
ispartof Magnetic resonance in medicine, 2005-11, Vol.54 (5), p.1094-1099
issn 0740-3194
1522-2594
language eng
recordid cdi_proquest_miscellaneous_20856945
source Wiley
subjects Angiography - methods
Animals
Cardiac Catheterization - methods
catheter-directed MR angiography
comparative studies
coronary angiography
Coronary Stenosis - diagnostic imaging
Coronary Stenosis - pathology
fluoroscopy
Fluoroscopy - methods
interventional MR
Magnetic Resonance Angiography - methods
Reproducibility of Results
Sensitivity and Specificity
Swine
title Comparison of X-ray fluoroscopy and interventional magnetic resonance imaging for the assessment of coronary artery stenoses in swine
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T08%3A54%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20X-ray%20fluoroscopy%20and%20interventional%20magnetic%20resonance%20imaging%20for%20the%20assessment%20of%20coronary%20artery%20stenoses%20in%20swine&rft.jtitle=Magnetic%20resonance%20in%20medicine&rft.au=Green,%20Jordin%20D.&rft.date=2005-11&rft.volume=54&rft.issue=5&rft.spage=1094&rft.epage=1099&rft.pages=1094-1099&rft.issn=0740-3194&rft.eissn=1522-2594&rft_id=info:doi/10.1002/mrm.20699&rft_dat=%3Cproquest_cross%3E20856945%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3969-6bd4283cbe0b6ecc030f75ff6d17b3b43fa98c07d8a4066a6549bd31278c8fb43%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=20856945&rft_id=info:pmid/16217784&rfr_iscdi=true