Bionic Single-Electrode Electronic Skin Unit Based on Piezoelectric Nanogenerator

Moravec’s paradox shows that low-level sensorimotor skills are more difficult than high-level reasoning in artificial intelligence and robotics. So simplifying every sensing unit on electronic skin is critical for endowing intelligent robots with tactile and temperature sense. The human nervous syst...

Full description

Saved in:
Bibliographic Details
Published in:ACS nano 2018-08, Vol.12 (8), p.8588-8596
Main Authors: Wang, Xiaoxiong, Song, Wei-Zhi, You, Ming-Hao, Zhang, Jun, Yu, Miao, Fan, Zhiyong, Ramakrishna, Seeram, Long, Yun-Ze
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-a333t-d74c9c2a8ec12f541a3dbd96fb307d8dcbc0a9c576d919bdfa31fa9ba3816f9c3
cites cdi_FETCH-LOGICAL-a333t-d74c9c2a8ec12f541a3dbd96fb307d8dcbc0a9c576d919bdfa31fa9ba3816f9c3
container_end_page 8596
container_issue 8
container_start_page 8588
container_title ACS nano
container_volume 12
creator Wang, Xiaoxiong
Song, Wei-Zhi
You, Ming-Hao
Zhang, Jun
Yu, Miao
Fan, Zhiyong
Ramakrishna, Seeram
Long, Yun-Ze
description Moravec’s paradox shows that low-level sensorimotor skills are more difficult than high-level reasoning in artificial intelligence and robotics. So simplifying every sensing unit on electronic skin is critical for endowing intelligent robots with tactile and temperature sense. The human nervous system is characterized by efficient single-electrode signal transmission, ensuring the efficiency and reliability of information transmission under big data conditions. In this work, we report a sensor based on a single-electrode piezoelectric nanogenerator (SPENG) by electrospun polyvinylidene fluoride (PVDF) nanofibers that can realize steady-state sensing of pressure integrating cold/heat sensing on a single unit. Piezoelectric signals appear as square wave signals, and the thermal-sensing signals appear as pulse signals. Therefore, the two signals can be acquired by a single unit simultaneously. The SPENG overcomes the shortcoming of electronic skins based on a single-electrode triboelectric nanogenerator (STENG), which can sense only dynamic movement and cannot sense temperature variations. The new sensor configuration uses a capacitor instead of the STENG’s ground wire as a potential reference, allowing it to be used for truly autonomous robots. At the same time, the traditional advantages of polymer piezoelectric materials, such as flexibility, transparency, and self-powered advantages, have also been preserved.
doi_str_mv 10.1021/acsnano.8b04244
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2088289957</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2088289957</sourcerecordid><originalsourceid>FETCH-LOGICAL-a333t-d74c9c2a8ec12f541a3dbd96fb307d8dcbc0a9c576d919bdfa31fa9ba3816f9c3</originalsourceid><addsrcrecordid>eNp1kEtLAzEUhYMotlbX7mSWgkybTOaRLG2pDyg-0IK7kNeU1GlSk5mF_npjO7pzdQ_c7xzuPQCcIzhGMEMTLoPl1o2JgHmW5wdgiCguU0jKt8M_XaABOAlhDWFRkao8BgMMo5sUeAiep8ZZI5MXY1eNTueNlq13Sie92u3ejU2W1rTJlAetEmeTJ6O_nN4hEXiIJ6y01Z63zp-Co5o3QZ_1cwSWN_PX2V26eLy9n10vUo4xblNV5ZLKjBMtUVYXOeJYCUXLWmBYKaKkkJBTWVSloogKVXOMak4FxwSVNZV4BC73uVvvPjodWrYxQeqm4Va7LrAMEpIRSosqopM9Kr0Lweuabb3ZcP_JEGQ_PbK-R9b3GB0XfXgnNlr98b_FReBqD0QnW7vO2_jrv3Hf-5d_pg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2088289957</pqid></control><display><type>article</type><title>Bionic Single-Electrode Electronic Skin Unit Based on Piezoelectric Nanogenerator</title><source>American Chemical Society:Jisc Collections:American Chemical Society Read &amp; Publish Agreement 2022-2024 (Reading list)</source><creator>Wang, Xiaoxiong ; Song, Wei-Zhi ; You, Ming-Hao ; Zhang, Jun ; Yu, Miao ; Fan, Zhiyong ; Ramakrishna, Seeram ; Long, Yun-Ze</creator><creatorcontrib>Wang, Xiaoxiong ; Song, Wei-Zhi ; You, Ming-Hao ; Zhang, Jun ; Yu, Miao ; Fan, Zhiyong ; Ramakrishna, Seeram ; Long, Yun-Ze</creatorcontrib><description>Moravec’s paradox shows that low-level sensorimotor skills are more difficult than high-level reasoning in artificial intelligence and robotics. So simplifying every sensing unit on electronic skin is critical for endowing intelligent robots with tactile and temperature sense. The human nervous system is characterized by efficient single-electrode signal transmission, ensuring the efficiency and reliability of information transmission under big data conditions. In this work, we report a sensor based on a single-electrode piezoelectric nanogenerator (SPENG) by electrospun polyvinylidene fluoride (PVDF) nanofibers that can realize steady-state sensing of pressure integrating cold/heat sensing on a single unit. Piezoelectric signals appear as square wave signals, and the thermal-sensing signals appear as pulse signals. Therefore, the two signals can be acquired by a single unit simultaneously. The SPENG overcomes the shortcoming of electronic skins based on a single-electrode triboelectric nanogenerator (STENG), which can sense only dynamic movement and cannot sense temperature variations. The new sensor configuration uses a capacitor instead of the STENG’s ground wire as a potential reference, allowing it to be used for truly autonomous robots. At the same time, the traditional advantages of polymer piezoelectric materials, such as flexibility, transparency, and self-powered advantages, have also been preserved.</description><identifier>ISSN: 1936-0851</identifier><identifier>EISSN: 1936-086X</identifier><identifier>DOI: 10.1021/acsnano.8b04244</identifier><identifier>PMID: 30102853</identifier><language>eng</language><publisher>United States: American Chemical Society</publisher><ispartof>ACS nano, 2018-08, Vol.12 (8), p.8588-8596</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a333t-d74c9c2a8ec12f541a3dbd96fb307d8dcbc0a9c576d919bdfa31fa9ba3816f9c3</citedby><cites>FETCH-LOGICAL-a333t-d74c9c2a8ec12f541a3dbd96fb307d8dcbc0a9c576d919bdfa31fa9ba3816f9c3</cites><orcidid>0000-0002-5397-0129 ; 0000-0001-8479-8686 ; 0000-0002-4278-4515</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30102853$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Wang, Xiaoxiong</creatorcontrib><creatorcontrib>Song, Wei-Zhi</creatorcontrib><creatorcontrib>You, Ming-Hao</creatorcontrib><creatorcontrib>Zhang, Jun</creatorcontrib><creatorcontrib>Yu, Miao</creatorcontrib><creatorcontrib>Fan, Zhiyong</creatorcontrib><creatorcontrib>Ramakrishna, Seeram</creatorcontrib><creatorcontrib>Long, Yun-Ze</creatorcontrib><title>Bionic Single-Electrode Electronic Skin Unit Based on Piezoelectric Nanogenerator</title><title>ACS nano</title><addtitle>ACS Nano</addtitle><description>Moravec’s paradox shows that low-level sensorimotor skills are more difficult than high-level reasoning in artificial intelligence and robotics. So simplifying every sensing unit on electronic skin is critical for endowing intelligent robots with tactile and temperature sense. The human nervous system is characterized by efficient single-electrode signal transmission, ensuring the efficiency and reliability of information transmission under big data conditions. In this work, we report a sensor based on a single-electrode piezoelectric nanogenerator (SPENG) by electrospun polyvinylidene fluoride (PVDF) nanofibers that can realize steady-state sensing of pressure integrating cold/heat sensing on a single unit. Piezoelectric signals appear as square wave signals, and the thermal-sensing signals appear as pulse signals. Therefore, the two signals can be acquired by a single unit simultaneously. The SPENG overcomes the shortcoming of electronic skins based on a single-electrode triboelectric nanogenerator (STENG), which can sense only dynamic movement and cannot sense temperature variations. The new sensor configuration uses a capacitor instead of the STENG’s ground wire as a potential reference, allowing it to be used for truly autonomous robots. At the same time, the traditional advantages of polymer piezoelectric materials, such as flexibility, transparency, and self-powered advantages, have also been preserved.</description><issn>1936-0851</issn><issn>1936-086X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp1kEtLAzEUhYMotlbX7mSWgkybTOaRLG2pDyg-0IK7kNeU1GlSk5mF_npjO7pzdQ_c7xzuPQCcIzhGMEMTLoPl1o2JgHmW5wdgiCguU0jKt8M_XaABOAlhDWFRkao8BgMMo5sUeAiep8ZZI5MXY1eNTueNlq13Sie92u3ejU2W1rTJlAetEmeTJ6O_nN4hEXiIJ6y01Z63zp-Co5o3QZ_1cwSWN_PX2V26eLy9n10vUo4xblNV5ZLKjBMtUVYXOeJYCUXLWmBYKaKkkJBTWVSloogKVXOMak4FxwSVNZV4BC73uVvvPjodWrYxQeqm4Va7LrAMEpIRSosqopM9Kr0Lweuabb3ZcP_JEGQ_PbK-R9b3GB0XfXgnNlr98b_FReBqD0QnW7vO2_jrv3Hf-5d_pg</recordid><startdate>20180828</startdate><enddate>20180828</enddate><creator>Wang, Xiaoxiong</creator><creator>Song, Wei-Zhi</creator><creator>You, Ming-Hao</creator><creator>Zhang, Jun</creator><creator>Yu, Miao</creator><creator>Fan, Zhiyong</creator><creator>Ramakrishna, Seeram</creator><creator>Long, Yun-Ze</creator><general>American Chemical Society</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-5397-0129</orcidid><orcidid>https://orcid.org/0000-0001-8479-8686</orcidid><orcidid>https://orcid.org/0000-0002-4278-4515</orcidid></search><sort><creationdate>20180828</creationdate><title>Bionic Single-Electrode Electronic Skin Unit Based on Piezoelectric Nanogenerator</title><author>Wang, Xiaoxiong ; Song, Wei-Zhi ; You, Ming-Hao ; Zhang, Jun ; Yu, Miao ; Fan, Zhiyong ; Ramakrishna, Seeram ; Long, Yun-Ze</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a333t-d74c9c2a8ec12f541a3dbd96fb307d8dcbc0a9c576d919bdfa31fa9ba3816f9c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wang, Xiaoxiong</creatorcontrib><creatorcontrib>Song, Wei-Zhi</creatorcontrib><creatorcontrib>You, Ming-Hao</creatorcontrib><creatorcontrib>Zhang, Jun</creatorcontrib><creatorcontrib>Yu, Miao</creatorcontrib><creatorcontrib>Fan, Zhiyong</creatorcontrib><creatorcontrib>Ramakrishna, Seeram</creatorcontrib><creatorcontrib>Long, Yun-Ze</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>ACS nano</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wang, Xiaoxiong</au><au>Song, Wei-Zhi</au><au>You, Ming-Hao</au><au>Zhang, Jun</au><au>Yu, Miao</au><au>Fan, Zhiyong</au><au>Ramakrishna, Seeram</au><au>Long, Yun-Ze</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Bionic Single-Electrode Electronic Skin Unit Based on Piezoelectric Nanogenerator</atitle><jtitle>ACS nano</jtitle><addtitle>ACS Nano</addtitle><date>2018-08-28</date><risdate>2018</risdate><volume>12</volume><issue>8</issue><spage>8588</spage><epage>8596</epage><pages>8588-8596</pages><issn>1936-0851</issn><eissn>1936-086X</eissn><abstract>Moravec’s paradox shows that low-level sensorimotor skills are more difficult than high-level reasoning in artificial intelligence and robotics. So simplifying every sensing unit on electronic skin is critical for endowing intelligent robots with tactile and temperature sense. The human nervous system is characterized by efficient single-electrode signal transmission, ensuring the efficiency and reliability of information transmission under big data conditions. In this work, we report a sensor based on a single-electrode piezoelectric nanogenerator (SPENG) by electrospun polyvinylidene fluoride (PVDF) nanofibers that can realize steady-state sensing of pressure integrating cold/heat sensing on a single unit. Piezoelectric signals appear as square wave signals, and the thermal-sensing signals appear as pulse signals. Therefore, the two signals can be acquired by a single unit simultaneously. The SPENG overcomes the shortcoming of electronic skins based on a single-electrode triboelectric nanogenerator (STENG), which can sense only dynamic movement and cannot sense temperature variations. The new sensor configuration uses a capacitor instead of the STENG’s ground wire as a potential reference, allowing it to be used for truly autonomous robots. At the same time, the traditional advantages of polymer piezoelectric materials, such as flexibility, transparency, and self-powered advantages, have also been preserved.</abstract><cop>United States</cop><pub>American Chemical Society</pub><pmid>30102853</pmid><doi>10.1021/acsnano.8b04244</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0002-5397-0129</orcidid><orcidid>https://orcid.org/0000-0001-8479-8686</orcidid><orcidid>https://orcid.org/0000-0002-4278-4515</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1936-0851
ispartof ACS nano, 2018-08, Vol.12 (8), p.8588-8596
issn 1936-0851
1936-086X
language eng
recordid cdi_proquest_miscellaneous_2088289957
source American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list)
title Bionic Single-Electrode Electronic Skin Unit Based on Piezoelectric Nanogenerator
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T23%3A41%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Bionic%20Single-Electrode%20Electronic%20Skin%20Unit%20Based%20on%20Piezoelectric%20Nanogenerator&rft.jtitle=ACS%20nano&rft.au=Wang,%20Xiaoxiong&rft.date=2018-08-28&rft.volume=12&rft.issue=8&rft.spage=8588&rft.epage=8596&rft.pages=8588-8596&rft.issn=1936-0851&rft.eissn=1936-086X&rft_id=info:doi/10.1021/acsnano.8b04244&rft_dat=%3Cproquest_cross%3E2088289957%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a333t-d74c9c2a8ec12f541a3dbd96fb307d8dcbc0a9c576d919bdfa31fa9ba3816f9c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2088289957&rft_id=info:pmid/30102853&rfr_iscdi=true