Loading…

Establishment of a CFD-based kL a model in microtiter plates to support CHO cell culture scale-up during clone selection

Microtiter plates are a common tool for clone selection in biopharmaceutical development. A way of visualizing and evaluating these systems and key processes parameters is the application of Computational Fluid Dynamics (CFD). CFD is a powerful tool for the modelling of hydrodynamics and mass transf...

Full description

Saved in:
Bibliographic Details
Published in:Biotechnology progress 2018-09, Vol.34 (5), p.1120-1128
Main Authors: Wutz, Johannes, Steiner, Robin, Assfalg, Kerstin, Wucherpfennig, Thomas
Format: Article
Language:English
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 1128
container_issue 5
container_start_page 1120
container_title Biotechnology progress
container_volume 34
creator Wutz, Johannes
Steiner, Robin
Assfalg, Kerstin
Wucherpfennig, Thomas
description Microtiter plates are a common tool for clone selection in biopharmaceutical development. A way of visualizing and evaluating these systems and key processes parameters is the application of Computational Fluid Dynamics (CFD). CFD is a powerful tool for the modelling of hydrodynamics and mass transfer parameters. In this work, CFD was used to determine the specific surface area, the volumetric power input and the oxygen mass transfer coefficient kL a for two different microtiter plates with different scales (100 μL - 5 mL). For this purpose, a new method of predicting the kL a is presented and calibrated with literature data. Scaling effects in shaken microtiter plates are evaluated by comparing two culture volume scales under various operating conditions. To test validity of these models, three different Boehringer Ingelheim Pharma proprietary CHO production cell lines with different growth characteristics were cultivated using the respective microtiter plates under different conditions until limitations in growth and viability were observable. The cell culture data then was compared to different parameters obtained by CFD. The calculated kL a values match the cell culture performance in the 96-deepwell by predicting lowered oxygen transfer with increasing culture volume and decreasing orbital velocity. The same cells behave differently in the 6-deepwell scale. Here, the overall larger shear stress might cause physical stress for the cells. The kL a model predicts overall higher shear rates for this system, supporting the experimental findings. © 2018 American Institute of Chemical Engineers Biotechnol. Prog., 2018.
doi_str_mv 10.1002/btpr.2707
format article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_2116125550</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2116125550</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_21161255503</originalsourceid><addsrcrecordid>eNqVjMFKAzEURUNBsFoX_YO3dDP1JcNMux9buhDcuC-ZzKtGM0ma9wJ-vhX8AVeXczhcpdYaNxrRPI2Sy8ZscbtQS90ZbHps21t1x_yJiDvszVJ971nsGDx_zBQF0hksDIfnZrRME3y9XHFOEwXwEWbvShIvVCAHK8QgCbjmnIrAcHwFRyGAq0FqIWBnAzU1w1SLj-_gQopXS4Gc-BRX6uZsA9PD396rx8P-bTg2uaRLJZbT7Pn30EZKlU9G616bruuw_Uf6A6OcVHI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2116125550</pqid></control><display><type>article</type><title>Establishment of a CFD-based kL a model in microtiter plates to support CHO cell culture scale-up during clone selection</title><source>Wiley</source><creator>Wutz, Johannes ; Steiner, Robin ; Assfalg, Kerstin ; Wucherpfennig, Thomas</creator><creatorcontrib>Wutz, Johannes ; Steiner, Robin ; Assfalg, Kerstin ; Wucherpfennig, Thomas</creatorcontrib><description>Microtiter plates are a common tool for clone selection in biopharmaceutical development. A way of visualizing and evaluating these systems and key processes parameters is the application of Computational Fluid Dynamics (CFD). CFD is a powerful tool for the modelling of hydrodynamics and mass transfer parameters. In this work, CFD was used to determine the specific surface area, the volumetric power input and the oxygen mass transfer coefficient kL a for two different microtiter plates with different scales (100 μL - 5 mL). For this purpose, a new method of predicting the kL a is presented and calibrated with literature data. Scaling effects in shaken microtiter plates are evaluated by comparing two culture volume scales under various operating conditions. To test validity of these models, three different Boehringer Ingelheim Pharma proprietary CHO production cell lines with different growth characteristics were cultivated using the respective microtiter plates under different conditions until limitations in growth and viability were observable. The cell culture data then was compared to different parameters obtained by CFD. The calculated kL a values match the cell culture performance in the 96-deepwell by predicting lowered oxygen transfer with increasing culture volume and decreasing orbital velocity. The same cells behave differently in the 6-deepwell scale. Here, the overall larger shear stress might cause physical stress for the cells. The kL a model predicts overall higher shear rates for this system, supporting the experimental findings. © 2018 American Institute of Chemical Engineers Biotechnol. Prog., 2018.</description><identifier>EISSN: 1520-6033</identifier><identifier>DOI: 10.1002/btpr.2707</identifier><language>eng</language><ispartof>Biotechnology progress, 2018-09, Vol.34 (5), p.1120-1128</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Wutz, Johannes</creatorcontrib><creatorcontrib>Steiner, Robin</creatorcontrib><creatorcontrib>Assfalg, Kerstin</creatorcontrib><creatorcontrib>Wucherpfennig, Thomas</creatorcontrib><title>Establishment of a CFD-based kL a model in microtiter plates to support CHO cell culture scale-up during clone selection</title><title>Biotechnology progress</title><description>Microtiter plates are a common tool for clone selection in biopharmaceutical development. A way of visualizing and evaluating these systems and key processes parameters is the application of Computational Fluid Dynamics (CFD). CFD is a powerful tool for the modelling of hydrodynamics and mass transfer parameters. In this work, CFD was used to determine the specific surface area, the volumetric power input and the oxygen mass transfer coefficient kL a for two different microtiter plates with different scales (100 μL - 5 mL). For this purpose, a new method of predicting the kL a is presented and calibrated with literature data. Scaling effects in shaken microtiter plates are evaluated by comparing two culture volume scales under various operating conditions. To test validity of these models, three different Boehringer Ingelheim Pharma proprietary CHO production cell lines with different growth characteristics were cultivated using the respective microtiter plates under different conditions until limitations in growth and viability were observable. The cell culture data then was compared to different parameters obtained by CFD. The calculated kL a values match the cell culture performance in the 96-deepwell by predicting lowered oxygen transfer with increasing culture volume and decreasing orbital velocity. The same cells behave differently in the 6-deepwell scale. Here, the overall larger shear stress might cause physical stress for the cells. The kL a model predicts overall higher shear rates for this system, supporting the experimental findings. © 2018 American Institute of Chemical Engineers Biotechnol. Prog., 2018.</description><issn>1520-6033</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqVjMFKAzEURUNBsFoX_YO3dDP1JcNMux9buhDcuC-ZzKtGM0ma9wJ-vhX8AVeXczhcpdYaNxrRPI2Sy8ZscbtQS90ZbHps21t1x_yJiDvszVJ971nsGDx_zBQF0hksDIfnZrRME3y9XHFOEwXwEWbvShIvVCAHK8QgCbjmnIrAcHwFRyGAq0FqIWBnAzU1w1SLj-_gQopXS4Gc-BRX6uZsA9PD396rx8P-bTg2uaRLJZbT7Pn30EZKlU9G616bruuw_Uf6A6OcVHI</recordid><startdate>20180901</startdate><enddate>20180901</enddate><creator>Wutz, Johannes</creator><creator>Steiner, Robin</creator><creator>Assfalg, Kerstin</creator><creator>Wucherpfennig, Thomas</creator><scope>7X8</scope></search><sort><creationdate>20180901</creationdate><title>Establishment of a CFD-based kL a model in microtiter plates to support CHO cell culture scale-up during clone selection</title><author>Wutz, Johannes ; Steiner, Robin ; Assfalg, Kerstin ; Wucherpfennig, Thomas</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_21161255503</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wutz, Johannes</creatorcontrib><creatorcontrib>Steiner, Robin</creatorcontrib><creatorcontrib>Assfalg, Kerstin</creatorcontrib><creatorcontrib>Wucherpfennig, Thomas</creatorcontrib><collection>MEDLINE - Academic</collection><jtitle>Biotechnology progress</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wutz, Johannes</au><au>Steiner, Robin</au><au>Assfalg, Kerstin</au><au>Wucherpfennig, Thomas</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Establishment of a CFD-based kL a model in microtiter plates to support CHO cell culture scale-up during clone selection</atitle><jtitle>Biotechnology progress</jtitle><date>2018-09-01</date><risdate>2018</risdate><volume>34</volume><issue>5</issue><spage>1120</spage><epage>1128</epage><pages>1120-1128</pages><eissn>1520-6033</eissn><abstract>Microtiter plates are a common tool for clone selection in biopharmaceutical development. A way of visualizing and evaluating these systems and key processes parameters is the application of Computational Fluid Dynamics (CFD). CFD is a powerful tool for the modelling of hydrodynamics and mass transfer parameters. In this work, CFD was used to determine the specific surface area, the volumetric power input and the oxygen mass transfer coefficient kL a for two different microtiter plates with different scales (100 μL - 5 mL). For this purpose, a new method of predicting the kL a is presented and calibrated with literature data. Scaling effects in shaken microtiter plates are evaluated by comparing two culture volume scales under various operating conditions. To test validity of these models, three different Boehringer Ingelheim Pharma proprietary CHO production cell lines with different growth characteristics were cultivated using the respective microtiter plates under different conditions until limitations in growth and viability were observable. The cell culture data then was compared to different parameters obtained by CFD. The calculated kL a values match the cell culture performance in the 96-deepwell by predicting lowered oxygen transfer with increasing culture volume and decreasing orbital velocity. The same cells behave differently in the 6-deepwell scale. Here, the overall larger shear stress might cause physical stress for the cells. The kL a model predicts overall higher shear rates for this system, supporting the experimental findings. © 2018 American Institute of Chemical Engineers Biotechnol. Prog., 2018.</abstract><doi>10.1002/btpr.2707</doi></addata></record>
fulltext fulltext
identifier EISSN: 1520-6033
ispartof Biotechnology progress, 2018-09, Vol.34 (5), p.1120-1128
issn 1520-6033
language eng
recordid cdi_proquest_miscellaneous_2116125550
source Wiley
title Establishment of a CFD-based kL a model in microtiter plates to support CHO cell culture scale-up during clone selection
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T10%3A08%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Establishment%20of%20a%20CFD-based%20kL%20a%20model%20in%20microtiter%20plates%20to%20support%20CHO%20cell%20culture%20scale-up%20during%20clone%20selection&rft.jtitle=Biotechnology%20progress&rft.au=Wutz,%20Johannes&rft.date=2018-09-01&rft.volume=34&rft.issue=5&rft.spage=1120&rft.epage=1128&rft.pages=1120-1128&rft.eissn=1520-6033&rft_id=info:doi/10.1002/btpr.2707&rft_dat=%3Cproquest%3E2116125550%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-proquest_miscellaneous_21161255503%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2116125550&rft_id=info:pmid/&rfr_iscdi=true