Loading…

Influence of distortions of recorded diffraction patterns on strain analysis by nano-beam electron diffraction

•Measurement and correction of diffraction pattern distortions.•Influence of diffraction pattern distortions on measurements of strain.•Influence of diffraction pattern distortions on measurements of tetragonal distortions.•Comparison of two techniques for the detection of diffraction disc positions...

Full description

Saved in:
Bibliographic Details
Published in:Ultramicroscopy 2019-01, Vol.196, p.74-82
Main Authors: Mahr, Christoph, Müller-Caspary, Knut, Ritz, Robert, Simson, Martin, Grieb, Tim, Schowalter, Marco, Krause, Florian F., Lackmann, Anastasia, Soltau, Heike, Wittstock, Arne, Rosenauer, Andreas
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c434t-3da6db0f1ab005c444d2d4f1a755db049004a69a37535caf9f6bd04d08be4873
cites cdi_FETCH-LOGICAL-c434t-3da6db0f1ab005c444d2d4f1a755db049004a69a37535caf9f6bd04d08be4873
container_end_page 82
container_issue
container_start_page 74
container_title Ultramicroscopy
container_volume 196
creator Mahr, Christoph
Müller-Caspary, Knut
Ritz, Robert
Simson, Martin
Grieb, Tim
Schowalter, Marco
Krause, Florian F.
Lackmann, Anastasia
Soltau, Heike
Wittstock, Arne
Rosenauer, Andreas
description •Measurement and correction of diffraction pattern distortions.•Influence of diffraction pattern distortions on measurements of strain.•Influence of diffraction pattern distortions on measurements of tetragonal distortions.•Comparison of two techniques for the detection of diffraction disc positions. Images acquired in transmission electron microscopes can be distorted for various reasons such as e.g. aberrations of the lenses of the imaging system or inaccuracies of the image recording system. This results in inaccuracies of measures obtained from the distorted images. Here we report on measurement and correction of elliptical distortions of diffraction patterns. The effect of this correction on the measurement of crystal lattice strain is investigated. We show that the effect of the distortions is smaller than the precision of the measurement in cases where the strain is obtained from shifts of diffracted discs with respect to their positions in images acquired in an unstrained reference area of the sample. This can be explained by the fact that diffraction patterns acquired in the strain free reference area of the sample are distorted in the same manner as the diffraction patterns acquired in the strained region of interest. In contrast, for samples without a strain free reference region such as nanoparticles or nanoporous structures, where we evaluate ratios of lattice plane distances along different directions, the distortions are usually not negligible. Furthermore, two techniques for the detection of diffraction disc positions are compared showing that for samples in which the crystal orientation changes over the investigated area it is more precise to detect the positions of many diffraction discs simultaneously instead of detecting each disc position independently.
doi_str_mv 10.1016/j.ultramic.2018.09.010
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2116843439</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0304399118300111</els_id><sourcerecordid>2116843439</sourcerecordid><originalsourceid>FETCH-LOGICAL-c434t-3da6db0f1ab005c444d2d4f1a755db049004a69a37535caf9f6bd04d08be4873</originalsourceid><addsrcrecordid>eNqFkE1v3CAQhlGUKtmm_QuRj7nYHQz-4JYqatqVIvWSO8IwSKxs2ACutP--WJtEueWEZniGd3gIuaXQUKD9j0OzzjmqxemmBTo2IBqgcEF2dBxE3Q4tuyQ7YMBrJgS9Jl9TOgAUhI9X5JpBK6gQ7Y74vbfzil5jFWxlXMohZhd82sqIOkSDpvStjUpvF9VR5YxxA3yVygrOV8qr-ZRcqqZT5ZUP9YRqqXBGnWOhPkx_I1-smhN-fz1vyPPjr-eHP_XT39_7h59PteaM55oZ1ZsJLFUTQKc556Y1vJRD15U-FwBc9UKxoWOdVlbYfjLADYwT8nFgN-Tu_OwxhpcVU5aLSxrnWXkMa5Itpf1YkpgoaH9GdQwpRbTyGN2i4klSkJtqeZBvquWmWoKQxWMZvH3NWKcFzfvYm9sC3J8BLB_95zDKpN1m2rgiNksT3GcZ_wFWL5XO</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2116843439</pqid></control><display><type>article</type><title>Influence of distortions of recorded diffraction patterns on strain analysis by nano-beam electron diffraction</title><source>ScienceDirect Journals</source><creator>Mahr, Christoph ; Müller-Caspary, Knut ; Ritz, Robert ; Simson, Martin ; Grieb, Tim ; Schowalter, Marco ; Krause, Florian F. ; Lackmann, Anastasia ; Soltau, Heike ; Wittstock, Arne ; Rosenauer, Andreas</creator><creatorcontrib>Mahr, Christoph ; Müller-Caspary, Knut ; Ritz, Robert ; Simson, Martin ; Grieb, Tim ; Schowalter, Marco ; Krause, Florian F. ; Lackmann, Anastasia ; Soltau, Heike ; Wittstock, Arne ; Rosenauer, Andreas</creatorcontrib><description>•Measurement and correction of diffraction pattern distortions.•Influence of diffraction pattern distortions on measurements of strain.•Influence of diffraction pattern distortions on measurements of tetragonal distortions.•Comparison of two techniques for the detection of diffraction disc positions. Images acquired in transmission electron microscopes can be distorted for various reasons such as e.g. aberrations of the lenses of the imaging system or inaccuracies of the image recording system. This results in inaccuracies of measures obtained from the distorted images. Here we report on measurement and correction of elliptical distortions of diffraction patterns. The effect of this correction on the measurement of crystal lattice strain is investigated. We show that the effect of the distortions is smaller than the precision of the measurement in cases where the strain is obtained from shifts of diffracted discs with respect to their positions in images acquired in an unstrained reference area of the sample. This can be explained by the fact that diffraction patterns acquired in the strain free reference area of the sample are distorted in the same manner as the diffraction patterns acquired in the strained region of interest. In contrast, for samples without a strain free reference region such as nanoparticles or nanoporous structures, where we evaluate ratios of lattice plane distances along different directions, the distortions are usually not negligible. Furthermore, two techniques for the detection of diffraction disc positions are compared showing that for samples in which the crystal orientation changes over the investigated area it is more precise to detect the positions of many diffraction discs simultaneously instead of detecting each disc position independently.</description><identifier>ISSN: 0304-3991</identifier><identifier>EISSN: 1879-2723</identifier><identifier>DOI: 10.1016/j.ultramic.2018.09.010</identifier><identifier>PMID: 30291992</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>4D-STEM ; Electron diffraction ; Image distortions ; Nanoporous gold ; Strain measurement</subject><ispartof>Ultramicroscopy, 2019-01, Vol.196, p.74-82</ispartof><rights>2018 Elsevier B.V.</rights><rights>Copyright © 2018 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c434t-3da6db0f1ab005c444d2d4f1a755db049004a69a37535caf9f6bd04d08be4873</citedby><cites>FETCH-LOGICAL-c434t-3da6db0f1ab005c444d2d4f1a755db049004a69a37535caf9f6bd04d08be4873</cites><orcidid>0000-0002-2588-7993</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30291992$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mahr, Christoph</creatorcontrib><creatorcontrib>Müller-Caspary, Knut</creatorcontrib><creatorcontrib>Ritz, Robert</creatorcontrib><creatorcontrib>Simson, Martin</creatorcontrib><creatorcontrib>Grieb, Tim</creatorcontrib><creatorcontrib>Schowalter, Marco</creatorcontrib><creatorcontrib>Krause, Florian F.</creatorcontrib><creatorcontrib>Lackmann, Anastasia</creatorcontrib><creatorcontrib>Soltau, Heike</creatorcontrib><creatorcontrib>Wittstock, Arne</creatorcontrib><creatorcontrib>Rosenauer, Andreas</creatorcontrib><title>Influence of distortions of recorded diffraction patterns on strain analysis by nano-beam electron diffraction</title><title>Ultramicroscopy</title><addtitle>Ultramicroscopy</addtitle><description>•Measurement and correction of diffraction pattern distortions.•Influence of diffraction pattern distortions on measurements of strain.•Influence of diffraction pattern distortions on measurements of tetragonal distortions.•Comparison of two techniques for the detection of diffraction disc positions. Images acquired in transmission electron microscopes can be distorted for various reasons such as e.g. aberrations of the lenses of the imaging system or inaccuracies of the image recording system. This results in inaccuracies of measures obtained from the distorted images. Here we report on measurement and correction of elliptical distortions of diffraction patterns. The effect of this correction on the measurement of crystal lattice strain is investigated. We show that the effect of the distortions is smaller than the precision of the measurement in cases where the strain is obtained from shifts of diffracted discs with respect to their positions in images acquired in an unstrained reference area of the sample. This can be explained by the fact that diffraction patterns acquired in the strain free reference area of the sample are distorted in the same manner as the diffraction patterns acquired in the strained region of interest. In contrast, for samples without a strain free reference region such as nanoparticles or nanoporous structures, where we evaluate ratios of lattice plane distances along different directions, the distortions are usually not negligible. Furthermore, two techniques for the detection of diffraction disc positions are compared showing that for samples in which the crystal orientation changes over the investigated area it is more precise to detect the positions of many diffraction discs simultaneously instead of detecting each disc position independently.</description><subject>4D-STEM</subject><subject>Electron diffraction</subject><subject>Image distortions</subject><subject>Nanoporous gold</subject><subject>Strain measurement</subject><issn>0304-3991</issn><issn>1879-2723</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNqFkE1v3CAQhlGUKtmm_QuRj7nYHQz-4JYqatqVIvWSO8IwSKxs2ACutP--WJtEueWEZniGd3gIuaXQUKD9j0OzzjmqxemmBTo2IBqgcEF2dBxE3Q4tuyQ7YMBrJgS9Jl9TOgAUhI9X5JpBK6gQ7Y74vbfzil5jFWxlXMohZhd82sqIOkSDpvStjUpvF9VR5YxxA3yVygrOV8qr-ZRcqqZT5ZUP9YRqqXBGnWOhPkx_I1-smhN-fz1vyPPjr-eHP_XT39_7h59PteaM55oZ1ZsJLFUTQKc556Y1vJRD15U-FwBc9UKxoWOdVlbYfjLADYwT8nFgN-Tu_OwxhpcVU5aLSxrnWXkMa5Itpf1YkpgoaH9GdQwpRbTyGN2i4klSkJtqeZBvquWmWoKQxWMZvH3NWKcFzfvYm9sC3J8BLB_95zDKpN1m2rgiNksT3GcZ_wFWL5XO</recordid><startdate>201901</startdate><enddate>201901</enddate><creator>Mahr, Christoph</creator><creator>Müller-Caspary, Knut</creator><creator>Ritz, Robert</creator><creator>Simson, Martin</creator><creator>Grieb, Tim</creator><creator>Schowalter, Marco</creator><creator>Krause, Florian F.</creator><creator>Lackmann, Anastasia</creator><creator>Soltau, Heike</creator><creator>Wittstock, Arne</creator><creator>Rosenauer, Andreas</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-2588-7993</orcidid></search><sort><creationdate>201901</creationdate><title>Influence of distortions of recorded diffraction patterns on strain analysis by nano-beam electron diffraction</title><author>Mahr, Christoph ; Müller-Caspary, Knut ; Ritz, Robert ; Simson, Martin ; Grieb, Tim ; Schowalter, Marco ; Krause, Florian F. ; Lackmann, Anastasia ; Soltau, Heike ; Wittstock, Arne ; Rosenauer, Andreas</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c434t-3da6db0f1ab005c444d2d4f1a755db049004a69a37535caf9f6bd04d08be4873</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>4D-STEM</topic><topic>Electron diffraction</topic><topic>Image distortions</topic><topic>Nanoporous gold</topic><topic>Strain measurement</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mahr, Christoph</creatorcontrib><creatorcontrib>Müller-Caspary, Knut</creatorcontrib><creatorcontrib>Ritz, Robert</creatorcontrib><creatorcontrib>Simson, Martin</creatorcontrib><creatorcontrib>Grieb, Tim</creatorcontrib><creatorcontrib>Schowalter, Marco</creatorcontrib><creatorcontrib>Krause, Florian F.</creatorcontrib><creatorcontrib>Lackmann, Anastasia</creatorcontrib><creatorcontrib>Soltau, Heike</creatorcontrib><creatorcontrib>Wittstock, Arne</creatorcontrib><creatorcontrib>Rosenauer, Andreas</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Ultramicroscopy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mahr, Christoph</au><au>Müller-Caspary, Knut</au><au>Ritz, Robert</au><au>Simson, Martin</au><au>Grieb, Tim</au><au>Schowalter, Marco</au><au>Krause, Florian F.</au><au>Lackmann, Anastasia</au><au>Soltau, Heike</au><au>Wittstock, Arne</au><au>Rosenauer, Andreas</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Influence of distortions of recorded diffraction patterns on strain analysis by nano-beam electron diffraction</atitle><jtitle>Ultramicroscopy</jtitle><addtitle>Ultramicroscopy</addtitle><date>2019-01</date><risdate>2019</risdate><volume>196</volume><spage>74</spage><epage>82</epage><pages>74-82</pages><issn>0304-3991</issn><eissn>1879-2723</eissn><abstract>•Measurement and correction of diffraction pattern distortions.•Influence of diffraction pattern distortions on measurements of strain.•Influence of diffraction pattern distortions on measurements of tetragonal distortions.•Comparison of two techniques for the detection of diffraction disc positions. Images acquired in transmission electron microscopes can be distorted for various reasons such as e.g. aberrations of the lenses of the imaging system or inaccuracies of the image recording system. This results in inaccuracies of measures obtained from the distorted images. Here we report on measurement and correction of elliptical distortions of diffraction patterns. The effect of this correction on the measurement of crystal lattice strain is investigated. We show that the effect of the distortions is smaller than the precision of the measurement in cases where the strain is obtained from shifts of diffracted discs with respect to their positions in images acquired in an unstrained reference area of the sample. This can be explained by the fact that diffraction patterns acquired in the strain free reference area of the sample are distorted in the same manner as the diffraction patterns acquired in the strained region of interest. In contrast, for samples without a strain free reference region such as nanoparticles or nanoporous structures, where we evaluate ratios of lattice plane distances along different directions, the distortions are usually not negligible. Furthermore, two techniques for the detection of diffraction disc positions are compared showing that for samples in which the crystal orientation changes over the investigated area it is more precise to detect the positions of many diffraction discs simultaneously instead of detecting each disc position independently.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>30291992</pmid><doi>10.1016/j.ultramic.2018.09.010</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0002-2588-7993</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0304-3991
ispartof Ultramicroscopy, 2019-01, Vol.196, p.74-82
issn 0304-3991
1879-2723
language eng
recordid cdi_proquest_miscellaneous_2116843439
source ScienceDirect Journals
subjects 4D-STEM
Electron diffraction
Image distortions
Nanoporous gold
Strain measurement
title Influence of distortions of recorded diffraction patterns on strain analysis by nano-beam electron diffraction
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T09%3A47%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Influence%20of%20distortions%20of%20recorded%20diffraction%20patterns%20on%20strain%20analysis%20by%20nano-beam%20electron%20diffraction&rft.jtitle=Ultramicroscopy&rft.au=Mahr,%20Christoph&rft.date=2019-01&rft.volume=196&rft.spage=74&rft.epage=82&rft.pages=74-82&rft.issn=0304-3991&rft.eissn=1879-2723&rft_id=info:doi/10.1016/j.ultramic.2018.09.010&rft_dat=%3Cproquest_cross%3E2116843439%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c434t-3da6db0f1ab005c444d2d4f1a755db049004a69a37535caf9f6bd04d08be4873%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2116843439&rft_id=info:pmid/30291992&rfr_iscdi=true