Loading…

Target and matrix problems in the determination of trace elements in wood material by PIXE

Here, we present the analysis of wood to determine trace elements in tree rings. We have irradiated wood pieces directly, for thick target PIXE, and also thin samples obtained by chemical treatment of the wood material. Proton beam energies of 2.2 and 6.6 MeV were used to irradiate the targets. A co...

Full description

Saved in:
Bibliographic Details
Published in:Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms Beam interactions with materials and atoms, 1998-03, Vol.136, p.923-927
Main Authors: Romo-Kröger, C.M., López, L.A., Avila, M.J., Eaton, L.C.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c338t-ae5f400fcd3266f05e183b1a6ff791ba77fd3e7dbe7adf1563c5ce7a8dcbfacd3
cites cdi_FETCH-LOGICAL-c338t-ae5f400fcd3266f05e183b1a6ff791ba77fd3e7dbe7adf1563c5ce7a8dcbfacd3
container_end_page 927
container_issue
container_start_page 923
container_title Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms
container_volume 136
creator Romo-Kröger, C.M.
López, L.A.
Avila, M.J.
Eaton, L.C.
description Here, we present the analysis of wood to determine trace elements in tree rings. We have irradiated wood pieces directly, for thick target PIXE, and also thin samples obtained by chemical treatment of the wood material. Proton beam energies of 2.2 and 6.6 MeV were used to irradiate the targets. A controlled amount of Yttrium was added to the solution during sample preparation as an internal standard. This simplifies the normalization of our PIXE results and permits a minimization of errors in the determination of the solid angle and the proton total charge. A calibration of the PIXE results was performed by using a reference material from the National Institute of Standards and Technology (NIST). This allowed fitting some parameters used in the quantitative analysis program (TTPIXAN). Two problems related with thick target analysis were solved: high background radiation and the impossibility to monitor the beam current. The background was diminished by the deposition of a graphite layer on targets. A thin gold foil placed before the target, but shielded from the detector, permitted integration of the charge by a conductor wire.
doi_str_mv 10.1016/S0168-583X(97)00863-X
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_21378738</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0168583X9700863X</els_id><sourcerecordid>348804</sourcerecordid><originalsourceid>FETCH-LOGICAL-c338t-ae5f400fcd3266f05e183b1a6ff791ba77fd3e7dbe7adf1563c5ce7a8dcbfacd3</originalsourceid><addsrcrecordid>eNqFkM1KQzEQhYMoWKuPIGQluriaNM1NuhIpVQsFBSsUNyE3mWjk_tQkVfv2pq24dRYzs_jOYeYgdErJJSW0vHrKTRZcssX5SFwQIktWLPZQj0oxKEZcDvdR7w85REcxvpNcnPEeepnr8AoJ69biRqfgv_EydFUNTcS-xekNsIUEofGtTr5rcedwCtoAhsxAm7bYV9dt5RC8rnG1xo_TxeQYHThdRzj5nX30fDuZj--L2cPddHwzKwxjMhUauBsS4oxlg7J0hAOVrKK6dE6MaKWFcJaBsBUIbR3lJTPc5F1aUzmdVX10tvPNh3-sICbV-GigrnUL3SqqAWVCCiYzyHegCV2MAZxaBt_osFaUqE2Sapuk2sSkRkJtk1SLrLve6SB_8ekhqGg8tAasD2CSsp3_x-EHroZ-Dw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>21378738</pqid></control><display><type>article</type><title>Target and matrix problems in the determination of trace elements in wood material by PIXE</title><source>Elsevier</source><creator>Romo-Kröger, C.M. ; López, L.A. ; Avila, M.J. ; Eaton, L.C.</creator><creatorcontrib>Romo-Kröger, C.M. ; López, L.A. ; Avila, M.J. ; Eaton, L.C.</creatorcontrib><description>Here, we present the analysis of wood to determine trace elements in tree rings. We have irradiated wood pieces directly, for thick target PIXE, and also thin samples obtained by chemical treatment of the wood material. Proton beam energies of 2.2 and 6.6 MeV were used to irradiate the targets. A controlled amount of Yttrium was added to the solution during sample preparation as an internal standard. This simplifies the normalization of our PIXE results and permits a minimization of errors in the determination of the solid angle and the proton total charge. A calibration of the PIXE results was performed by using a reference material from the National Institute of Standards and Technology (NIST). This allowed fitting some parameters used in the quantitative analysis program (TTPIXAN). Two problems related with thick target analysis were solved: high background radiation and the impossibility to monitor the beam current. The background was diminished by the deposition of a graphite layer on targets. A thin gold foil placed before the target, but shielded from the detector, permitted integration of the charge by a conductor wire.</description><identifier>ISSN: 0168-583X</identifier><identifier>EISSN: 1872-9584</identifier><identifier>DOI: 10.1016/S0168-583X(97)00863-X</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Background suppression ; Beam monitoring ; Computer software ; Graphite ; Metal foil ; Particle beams ; Particle detectors ; PIXE ; Plants (botany) ; Protons ; Thick-thin samples ; Trace elements ; Wood ; Wood matrix ; Yttrium</subject><ispartof>Nuclear instruments &amp; methods in physics research. Section B, Beam interactions with materials and atoms, 1998-03, Vol.136, p.923-927</ispartof><rights>1998</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c338t-ae5f400fcd3266f05e183b1a6ff791ba77fd3e7dbe7adf1563c5ce7a8dcbfacd3</citedby><cites>FETCH-LOGICAL-c338t-ae5f400fcd3266f05e183b1a6ff791ba77fd3e7dbe7adf1563c5ce7a8dcbfacd3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids></links><search><creatorcontrib>Romo-Kröger, C.M.</creatorcontrib><creatorcontrib>López, L.A.</creatorcontrib><creatorcontrib>Avila, M.J.</creatorcontrib><creatorcontrib>Eaton, L.C.</creatorcontrib><title>Target and matrix problems in the determination of trace elements in wood material by PIXE</title><title>Nuclear instruments &amp; methods in physics research. Section B, Beam interactions with materials and atoms</title><description>Here, we present the analysis of wood to determine trace elements in tree rings. We have irradiated wood pieces directly, for thick target PIXE, and also thin samples obtained by chemical treatment of the wood material. Proton beam energies of 2.2 and 6.6 MeV were used to irradiate the targets. A controlled amount of Yttrium was added to the solution during sample preparation as an internal standard. This simplifies the normalization of our PIXE results and permits a minimization of errors in the determination of the solid angle and the proton total charge. A calibration of the PIXE results was performed by using a reference material from the National Institute of Standards and Technology (NIST). This allowed fitting some parameters used in the quantitative analysis program (TTPIXAN). Two problems related with thick target analysis were solved: high background radiation and the impossibility to monitor the beam current. The background was diminished by the deposition of a graphite layer on targets. A thin gold foil placed before the target, but shielded from the detector, permitted integration of the charge by a conductor wire.</description><subject>Background suppression</subject><subject>Beam monitoring</subject><subject>Computer software</subject><subject>Graphite</subject><subject>Metal foil</subject><subject>Particle beams</subject><subject>Particle detectors</subject><subject>PIXE</subject><subject>Plants (botany)</subject><subject>Protons</subject><subject>Thick-thin samples</subject><subject>Trace elements</subject><subject>Wood</subject><subject>Wood matrix</subject><subject>Yttrium</subject><issn>0168-583X</issn><issn>1872-9584</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNqFkM1KQzEQhYMoWKuPIGQluriaNM1NuhIpVQsFBSsUNyE3mWjk_tQkVfv2pq24dRYzs_jOYeYgdErJJSW0vHrKTRZcssX5SFwQIktWLPZQj0oxKEZcDvdR7w85REcxvpNcnPEeepnr8AoJ69biRqfgv_EydFUNTcS-xekNsIUEofGtTr5rcedwCtoAhsxAm7bYV9dt5RC8rnG1xo_TxeQYHThdRzj5nX30fDuZj--L2cPddHwzKwxjMhUauBsS4oxlg7J0hAOVrKK6dE6MaKWFcJaBsBUIbR3lJTPc5F1aUzmdVX10tvPNh3-sICbV-GigrnUL3SqqAWVCCiYzyHegCV2MAZxaBt_osFaUqE2Sapuk2sSkRkJtk1SLrLve6SB_8ekhqGg8tAasD2CSsp3_x-EHroZ-Dw</recordid><startdate>19980301</startdate><enddate>19980301</enddate><creator>Romo-Kröger, C.M.</creator><creator>López, L.A.</creator><creator>Avila, M.J.</creator><creator>Eaton, L.C.</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19980301</creationdate><title>Target and matrix problems in the determination of trace elements in wood material by PIXE</title><author>Romo-Kröger, C.M. ; López, L.A. ; Avila, M.J. ; Eaton, L.C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c338t-ae5f400fcd3266f05e183b1a6ff791ba77fd3e7dbe7adf1563c5ce7a8dcbfacd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Background suppression</topic><topic>Beam monitoring</topic><topic>Computer software</topic><topic>Graphite</topic><topic>Metal foil</topic><topic>Particle beams</topic><topic>Particle detectors</topic><topic>PIXE</topic><topic>Plants (botany)</topic><topic>Protons</topic><topic>Thick-thin samples</topic><topic>Trace elements</topic><topic>Wood</topic><topic>Wood matrix</topic><topic>Yttrium</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Romo-Kröger, C.M.</creatorcontrib><creatorcontrib>López, L.A.</creatorcontrib><creatorcontrib>Avila, M.J.</creatorcontrib><creatorcontrib>Eaton, L.C.</creatorcontrib><collection>CrossRef</collection><jtitle>Nuclear instruments &amp; methods in physics research. Section B, Beam interactions with materials and atoms</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Romo-Kröger, C.M.</au><au>López, L.A.</au><au>Avila, M.J.</au><au>Eaton, L.C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Target and matrix problems in the determination of trace elements in wood material by PIXE</atitle><jtitle>Nuclear instruments &amp; methods in physics research. Section B, Beam interactions with materials and atoms</jtitle><date>1998-03-01</date><risdate>1998</risdate><volume>136</volume><spage>923</spage><epage>927</epage><pages>923-927</pages><issn>0168-583X</issn><eissn>1872-9584</eissn><abstract>Here, we present the analysis of wood to determine trace elements in tree rings. We have irradiated wood pieces directly, for thick target PIXE, and also thin samples obtained by chemical treatment of the wood material. Proton beam energies of 2.2 and 6.6 MeV were used to irradiate the targets. A controlled amount of Yttrium was added to the solution during sample preparation as an internal standard. This simplifies the normalization of our PIXE results and permits a minimization of errors in the determination of the solid angle and the proton total charge. A calibration of the PIXE results was performed by using a reference material from the National Institute of Standards and Technology (NIST). This allowed fitting some parameters used in the quantitative analysis program (TTPIXAN). Two problems related with thick target analysis were solved: high background radiation and the impossibility to monitor the beam current. The background was diminished by the deposition of a graphite layer on targets. A thin gold foil placed before the target, but shielded from the detector, permitted integration of the charge by a conductor wire.</abstract><pub>Elsevier B.V</pub><doi>10.1016/S0168-583X(97)00863-X</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0168-583X
ispartof Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms, 1998-03, Vol.136, p.923-927
issn 0168-583X
1872-9584
language eng
recordid cdi_proquest_miscellaneous_21378738
source Elsevier
subjects Background suppression
Beam monitoring
Computer software
Graphite
Metal foil
Particle beams
Particle detectors
PIXE
Plants (botany)
Protons
Thick-thin samples
Trace elements
Wood
Wood matrix
Yttrium
title Target and matrix problems in the determination of trace elements in wood material by PIXE
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-26T23%3A50%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Target%20and%20matrix%20problems%20in%20the%20determination%20of%20trace%20elements%20in%20wood%20material%20by%20PIXE&rft.jtitle=Nuclear%20instruments%20&%20methods%20in%20physics%20research.%20Section%20B,%20Beam%20interactions%20with%20materials%20and%20atoms&rft.au=Romo-Kr%C3%B6ger,%20C.M.&rft.date=1998-03-01&rft.volume=136&rft.spage=923&rft.epage=927&rft.pages=923-927&rft.issn=0168-583X&rft.eissn=1872-9584&rft_id=info:doi/10.1016/S0168-583X(97)00863-X&rft_dat=%3Cproquest_cross%3E348804%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c338t-ae5f400fcd3266f05e183b1a6ff791ba77fd3e7dbe7adf1563c5ce7a8dcbfacd3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=21378738&rft_id=info:pmid/&rfr_iscdi=true