Gastight Sampler for Sequential Streamflow Sampling
The objective of this work was to design and construct an automatic gastight streamwater sampler capable of collecting samples during a 24-hour period. To minimize cost and complexity, wetted glass syringes with narrow collection tubes were used as sample containers. The streamwater sampler prototyp...
Saved in:
Published in: | Water environment research 2000-05, Vol.72 (3), p.377-381 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The objective of this work was to design and construct an automatic gastight streamwater sampler capable of collecting samples during a 24-hour period. To minimize cost and complexity, wetted glass syringes with narrow collection tubes were used as sample containers. The streamwater sampler prototype was tested in a stream that contained elevated levels of volatile organic compounds, and it worked satisfactorily under field conditions. Syringe collectors were a reliable and cost-effective method of acquiring sequential gastight water samples. |
---|---|
ISSN: | 1061-4303 1554-7531 |
DOI: | 10.2175/106143000X137897 |