Loading…

Gait analysis in a component timed-up-and-go test using a smartphone application

The timed-up-and-go test (TUG) is a popular test for mobility, but it only measures the total time to complete tasks. Recent advances in smartphone technology enables measuring respective times of 6 components in the test (Stand, Go, Turn1, Come, Turns and Sit). We examined availability of these dat...

Full description

Saved in:
Bibliographic Details
Published in:Journal of the neurological sciences 2019-03, Vol.398, p.45-49
Main Authors: Ishikawa, Masatsune, Yamada, Shigeki, Yamamoto, Kazuo, Aoyagi, Yukihiko
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c419t-510ddbb0262166b1231ad8634a633b50406865f6f114ee44628635329a53cf403
cites cdi_FETCH-LOGICAL-c419t-510ddbb0262166b1231ad8634a633b50406865f6f114ee44628635329a53cf403
container_end_page 49
container_issue
container_start_page 45
container_title Journal of the neurological sciences
container_volume 398
creator Ishikawa, Masatsune
Yamada, Shigeki
Yamamoto, Kazuo
Aoyagi, Yukihiko
description The timed-up-and-go test (TUG) is a popular test for mobility, but it only measures the total time to complete tasks. Recent advances in smartphone technology enables measuring respective times of 6 components in the test (Stand, Go, Turn1, Come, Turns and Sit). We examined availability of these data for assessing different gait patterns. This study enrolled 32 patients with probable idiopathic normal-pressure hydrocephalus and 87 age-matched active participants as controls. All the patients responded positively to cerebrospinal fluid (CSF) removal, among whom 19 underwent surgery with positive outcomes. The TUG was performed using a free smartphone application. The components were automatically detected, and their respective times were computed. Statistical analyses included item cluster analysis. In the control group, high correlations (r ≥ 0.7) were observed in two pairs of Go and Come, and Turn1 and Turn2, which reflect straight walk and turn. This pattern was lost in the baseline and after CSF removal in the hydrocephalus group. After surgery, the two pairs in the control group regained high correlations. The item cluster analysis showed the pattern changes more clearly. A smartphone is useful for analyzing gait patterns in the TUG, which can be applicable for various gait disorders. •Timed-up-and-go test is a popular gait test, but it measures only the total time.•The gait test is composed of Stand, Go, Turn1, Come, Turn2 and Sit.•A smartphone application measures respective times of six components on the test.•The pairs Go and Come, and Turn 1 and Turn2 in the control were 2 major clusters.•This pattern was lost in normal pressure hydrocephalus and restored by surgery.
doi_str_mv 10.1016/j.jns.2019.01.023
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2179456113</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0022510X19300231</els_id><sourcerecordid>2179456113</sourcerecordid><originalsourceid>FETCH-LOGICAL-c419t-510ddbb0262166b1231ad8634a633b50406865f6f114ee44628635329a53cf403</originalsourceid><addsrcrecordid>eNp9kMFKxDAQhoMo7rr6AF6kRy-tM0mbbfEkoquwoAcFbyFN0zWlTWuTCvv2ZtnVo6cJzDc_fz5CLhESBOQ3TdJYl1DAIgFMgLIjMsd8mcdZnrNjMgegNM4QPmbkzLkGAHieF6dkxsKDZhTm5HUljY-kle3WGRcZG8lI9d3QW2195E2nq3gaYmmreNNHXjsfTc7YTcBcJ0c_fAYyksPQGiW96e05Oall6_TFYS7I--PD2_1TvH5ZPd_frWOVYuF3raqqLIFyipyXSBnKKucslZyxMoM0NORZzWvEVOs05TQsM0YLmTFVp8AW5HqfO4z91xR6ic44pdtWWt1PTlBcFmnGEVlAcY-qsXdu1LUYRhPKbwWC2IkUjQgixU6kABRBZLi5OsRPZXDwd_FrLgC3e0CHT34bPQqnjLZKV2bUyouqN__E_wBilIHp</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2179456113</pqid></control><display><type>article</type><title>Gait analysis in a component timed-up-and-go test using a smartphone application</title><source>ScienceDirect Journals</source><creator>Ishikawa, Masatsune ; Yamada, Shigeki ; Yamamoto, Kazuo ; Aoyagi, Yukihiko</creator><creatorcontrib>Ishikawa, Masatsune ; Yamada, Shigeki ; Yamamoto, Kazuo ; Aoyagi, Yukihiko</creatorcontrib><description>The timed-up-and-go test (TUG) is a popular test for mobility, but it only measures the total time to complete tasks. Recent advances in smartphone technology enables measuring respective times of 6 components in the test (Stand, Go, Turn1, Come, Turns and Sit). We examined availability of these data for assessing different gait patterns. This study enrolled 32 patients with probable idiopathic normal-pressure hydrocephalus and 87 age-matched active participants as controls. All the patients responded positively to cerebrospinal fluid (CSF) removal, among whom 19 underwent surgery with positive outcomes. The TUG was performed using a free smartphone application. The components were automatically detected, and their respective times were computed. Statistical analyses included item cluster analysis. In the control group, high correlations (r ≥ 0.7) were observed in two pairs of Go and Come, and Turn1 and Turn2, which reflect straight walk and turn. This pattern was lost in the baseline and after CSF removal in the hydrocephalus group. After surgery, the two pairs in the control group regained high correlations. The item cluster analysis showed the pattern changes more clearly. A smartphone is useful for analyzing gait patterns in the TUG, which can be applicable for various gait disorders. •Timed-up-and-go test is a popular gait test, but it measures only the total time.•The gait test is composed of Stand, Go, Turn1, Come, Turn2 and Sit.•A smartphone application measures respective times of six components on the test.•The pairs Go and Come, and Turn 1 and Turn2 in the control were 2 major clusters.•This pattern was lost in normal pressure hydrocephalus and restored by surgery.</description><identifier>ISSN: 0022-510X</identifier><identifier>EISSN: 1878-5883</identifier><identifier>DOI: 10.1016/j.jns.2019.01.023</identifier><identifier>PMID: 30682520</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Aged ; Aged, 80 and over ; Female ; Gait ; Gait - physiology ; Gait Analysis - instrumentation ; Gait Analysis - methods ; Humans ; Hydrocephalus ; Hydrocephalus, Normal Pressure - diagnosis ; Hydrocephalus, Normal Pressure - physiopathology ; Male ; Smartphone ; Smartphone - instrumentation ; Time and Motion Studies ; Wearable Electronic Devices</subject><ispartof>Journal of the neurological sciences, 2019-03, Vol.398, p.45-49</ispartof><rights>2019 Elsevier B.V.</rights><rights>Copyright © 2019 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c419t-510ddbb0262166b1231ad8634a633b50406865f6f114ee44628635329a53cf403</citedby><cites>FETCH-LOGICAL-c419t-510ddbb0262166b1231ad8634a633b50406865f6f114ee44628635329a53cf403</cites><orcidid>0000-0001-7158-5569</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30682520$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ishikawa, Masatsune</creatorcontrib><creatorcontrib>Yamada, Shigeki</creatorcontrib><creatorcontrib>Yamamoto, Kazuo</creatorcontrib><creatorcontrib>Aoyagi, Yukihiko</creatorcontrib><title>Gait analysis in a component timed-up-and-go test using a smartphone application</title><title>Journal of the neurological sciences</title><addtitle>J Neurol Sci</addtitle><description>The timed-up-and-go test (TUG) is a popular test for mobility, but it only measures the total time to complete tasks. Recent advances in smartphone technology enables measuring respective times of 6 components in the test (Stand, Go, Turn1, Come, Turns and Sit). We examined availability of these data for assessing different gait patterns. This study enrolled 32 patients with probable idiopathic normal-pressure hydrocephalus and 87 age-matched active participants as controls. All the patients responded positively to cerebrospinal fluid (CSF) removal, among whom 19 underwent surgery with positive outcomes. The TUG was performed using a free smartphone application. The components were automatically detected, and their respective times were computed. Statistical analyses included item cluster analysis. In the control group, high correlations (r ≥ 0.7) were observed in two pairs of Go and Come, and Turn1 and Turn2, which reflect straight walk and turn. This pattern was lost in the baseline and after CSF removal in the hydrocephalus group. After surgery, the two pairs in the control group regained high correlations. The item cluster analysis showed the pattern changes more clearly. A smartphone is useful for analyzing gait patterns in the TUG, which can be applicable for various gait disorders. •Timed-up-and-go test is a popular gait test, but it measures only the total time.•The gait test is composed of Stand, Go, Turn1, Come, Turn2 and Sit.•A smartphone application measures respective times of six components on the test.•The pairs Go and Come, and Turn 1 and Turn2 in the control were 2 major clusters.•This pattern was lost in normal pressure hydrocephalus and restored by surgery.</description><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Female</subject><subject>Gait</subject><subject>Gait - physiology</subject><subject>Gait Analysis - instrumentation</subject><subject>Gait Analysis - methods</subject><subject>Humans</subject><subject>Hydrocephalus</subject><subject>Hydrocephalus, Normal Pressure - diagnosis</subject><subject>Hydrocephalus, Normal Pressure - physiopathology</subject><subject>Male</subject><subject>Smartphone</subject><subject>Smartphone - instrumentation</subject><subject>Time and Motion Studies</subject><subject>Wearable Electronic Devices</subject><issn>0022-510X</issn><issn>1878-5883</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp9kMFKxDAQhoMo7rr6AF6kRy-tM0mbbfEkoquwoAcFbyFN0zWlTWuTCvv2ZtnVo6cJzDc_fz5CLhESBOQ3TdJYl1DAIgFMgLIjMsd8mcdZnrNjMgegNM4QPmbkzLkGAHieF6dkxsKDZhTm5HUljY-kle3WGRcZG8lI9d3QW2195E2nq3gaYmmreNNHXjsfTc7YTcBcJ0c_fAYyksPQGiW96e05Oall6_TFYS7I--PD2_1TvH5ZPd_frWOVYuF3raqqLIFyipyXSBnKKucslZyxMoM0NORZzWvEVOs05TQsM0YLmTFVp8AW5HqfO4z91xR6ic44pdtWWt1PTlBcFmnGEVlAcY-qsXdu1LUYRhPKbwWC2IkUjQgixU6kABRBZLi5OsRPZXDwd_FrLgC3e0CHT34bPQqnjLZKV2bUyouqN__E_wBilIHp</recordid><startdate>20190315</startdate><enddate>20190315</enddate><creator>Ishikawa, Masatsune</creator><creator>Yamada, Shigeki</creator><creator>Yamamoto, Kazuo</creator><creator>Aoyagi, Yukihiko</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-7158-5569</orcidid></search><sort><creationdate>20190315</creationdate><title>Gait analysis in a component timed-up-and-go test using a smartphone application</title><author>Ishikawa, Masatsune ; Yamada, Shigeki ; Yamamoto, Kazuo ; Aoyagi, Yukihiko</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c419t-510ddbb0262166b1231ad8634a633b50406865f6f114ee44628635329a53cf403</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Female</topic><topic>Gait</topic><topic>Gait - physiology</topic><topic>Gait Analysis - instrumentation</topic><topic>Gait Analysis - methods</topic><topic>Humans</topic><topic>Hydrocephalus</topic><topic>Hydrocephalus, Normal Pressure - diagnosis</topic><topic>Hydrocephalus, Normal Pressure - physiopathology</topic><topic>Male</topic><topic>Smartphone</topic><topic>Smartphone - instrumentation</topic><topic>Time and Motion Studies</topic><topic>Wearable Electronic Devices</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ishikawa, Masatsune</creatorcontrib><creatorcontrib>Yamada, Shigeki</creatorcontrib><creatorcontrib>Yamamoto, Kazuo</creatorcontrib><creatorcontrib>Aoyagi, Yukihiko</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of the neurological sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ishikawa, Masatsune</au><au>Yamada, Shigeki</au><au>Yamamoto, Kazuo</au><au>Aoyagi, Yukihiko</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Gait analysis in a component timed-up-and-go test using a smartphone application</atitle><jtitle>Journal of the neurological sciences</jtitle><addtitle>J Neurol Sci</addtitle><date>2019-03-15</date><risdate>2019</risdate><volume>398</volume><spage>45</spage><epage>49</epage><pages>45-49</pages><issn>0022-510X</issn><eissn>1878-5883</eissn><abstract>The timed-up-and-go test (TUG) is a popular test for mobility, but it only measures the total time to complete tasks. Recent advances in smartphone technology enables measuring respective times of 6 components in the test (Stand, Go, Turn1, Come, Turns and Sit). We examined availability of these data for assessing different gait patterns. This study enrolled 32 patients with probable idiopathic normal-pressure hydrocephalus and 87 age-matched active participants as controls. All the patients responded positively to cerebrospinal fluid (CSF) removal, among whom 19 underwent surgery with positive outcomes. The TUG was performed using a free smartphone application. The components were automatically detected, and their respective times were computed. Statistical analyses included item cluster analysis. In the control group, high correlations (r ≥ 0.7) were observed in two pairs of Go and Come, and Turn1 and Turn2, which reflect straight walk and turn. This pattern was lost in the baseline and after CSF removal in the hydrocephalus group. After surgery, the two pairs in the control group regained high correlations. The item cluster analysis showed the pattern changes more clearly. A smartphone is useful for analyzing gait patterns in the TUG, which can be applicable for various gait disorders. •Timed-up-and-go test is a popular gait test, but it measures only the total time.•The gait test is composed of Stand, Go, Turn1, Come, Turn2 and Sit.•A smartphone application measures respective times of six components on the test.•The pairs Go and Come, and Turn 1 and Turn2 in the control were 2 major clusters.•This pattern was lost in normal pressure hydrocephalus and restored by surgery.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>30682520</pmid><doi>10.1016/j.jns.2019.01.023</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0001-7158-5569</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0022-510X
ispartof Journal of the neurological sciences, 2019-03, Vol.398, p.45-49
issn 0022-510X
1878-5883
language eng
recordid cdi_proquest_miscellaneous_2179456113
source ScienceDirect Journals
subjects Aged
Aged, 80 and over
Female
Gait
Gait - physiology
Gait Analysis - instrumentation
Gait Analysis - methods
Humans
Hydrocephalus
Hydrocephalus, Normal Pressure - diagnosis
Hydrocephalus, Normal Pressure - physiopathology
Male
Smartphone
Smartphone - instrumentation
Time and Motion Studies
Wearable Electronic Devices
title Gait analysis in a component timed-up-and-go test using a smartphone application
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T11%3A40%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Gait%20analysis%20in%20a%20component%20timed-up-and-go%20test%20using%20a%20smartphone%20application&rft.jtitle=Journal%20of%20the%20neurological%20sciences&rft.au=Ishikawa,%20Masatsune&rft.date=2019-03-15&rft.volume=398&rft.spage=45&rft.epage=49&rft.pages=45-49&rft.issn=0022-510X&rft.eissn=1878-5883&rft_id=info:doi/10.1016/j.jns.2019.01.023&rft_dat=%3Cproquest_cross%3E2179456113%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c419t-510ddbb0262166b1231ad8634a633b50406865f6f114ee44628635329a53cf403%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2179456113&rft_id=info:pmid/30682520&rfr_iscdi=true