Loading…

Serial Optical Coherence Tomography at Baseline, 7 Days, and 1, 3, 6 and 12 Months After Bioresorbable Scaffold Implantation in a Growing Porcine Model

Background: Little is known about serial changes in lumen and device dimensions after bioresorbable scaffold implantation in a growing animal model. Methods and Results: ABSORB (n=14) or bare metal stents (ICROS amg [Abbott Vascular, Santa Clara, CA, USA], Winsen-Luhe, Germany; n=15) were implanted...

Full description

Saved in:
Bibliographic Details
Published in:Circulation Journal 2019/02/25, Vol.83(3), pp.556-566
Main Authors: Asano, Taku, Hytönen, Jarkko, Chichareon, Ply, Taavitsainen, Jouni, Kogame, Norihiro, Katagiri, Yuki, Miyazaki, Yosuke, Takahashi, Kuniaki, Modolo, Rodrigo, Komiyama, Hidenori, Tenekecioglu, Erhan, Sotomi, Yohei, Wykrzykowska, Joanna J., Piek, Jan J., Martin, John, Baumbach, Andreas, Mathur, Anthony, Onuma, Yoshinobu, Ylä-Herttuala, Seppo, Serruys, Patrick W.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background: Little is known about serial changes in lumen and device dimensions after bioresorbable scaffold implantation in a growing animal model. Methods and Results: ABSORB (n=14) or bare metal stents (ICROS amg [Abbott Vascular, Santa Clara, CA, USA], Winsen-Luhe, Germany; n=15) were implanted in the coronary arteries of domestic swine (a hybrid of Finnish-Norwegian Landrace swine) weighing 30–35 kg. Angiography and optical coherence tomography (OCT) were performed immediately after implantation and repeated at 7 days, 1, 3, 6 and 12 months after the index procedure. One month after implantation, mean lumen area decreased relative to baseline in both groups (relative area change from baseline, −41.4±15.6% for ABSORB vs. −20.9±18.6% for ICROS) while mean device area decreased only in the ABSORB group (relative area change: −11.1±9.4% vs. +0.14±7.95%, respectively). At 12 months, mean lumen area increased relative to baseline in both groups (relative area change from baseline, +55.6±22.4% vs. +32.3±83.6%, respectively) in accordance with the swine growth weighing up to 260–300 kg. Mean device area in the ICROS group remained stable whereas that in the ABSORB group began to increase between 3 and 6 months along with the vessel growth (relative area change: +107.8±25.7% vs. +0.14±7.95%). Conclusions: In the growing porcine model, ABSORB was associated with greater extent of recoil 1 month after implantation compared with ICROS but demonstrated substantial adaptability to vessel growth in late phase.
ISSN:1346-9843
1347-4820
1347-4820