Implications of Extracranial Distortion in Ultra-High-Field Magnetic Resonance Imaging for Image-Guided Cranial Neurosurgery

Ultra-high-field magnetic resonance imaging (MRI) of the brain is attractive for image guidance during neurosurgery because of its high tissue contrast and detailed vessel visualization. However, high-field MRI is prone to distortion artifacts, which may compromise image guidance. Here we investigat...

Full description

Saved in:
Bibliographic Details
Published in:World neurosurgery 2019-06, Vol.126, p.e250-e258
Main Authors: Voormolen, Eduard H., Diederen, Sander J.H., Woerdeman, Peter, van der Sprenkel, Jan Willem Berkelbach, Noordmans, Herke Jan, Visser, Fredy, Viergever, Max A., Luijten, Peter, Hoogduin, Hans, Robe, Pierre A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Ultra-high-field magnetic resonance imaging (MRI) of the brain is attractive for image guidance during neurosurgery because of its high tissue contrast and detailed vessel visualization. However, high-field MRI is prone to distortion artifacts, which may compromise image guidance. Here we investigate intra- and extracranial distortions in 7-T MRI scans. Five patients with and 5 patients without skin-adhesive fiducials received magnetization-prepared T1-weighted 7-T MRI and standard 3-T MRI scans. The 7- and 3-T images were rigidly coregistered and compared. Intracranial distortions were evaluated qualitatively, whereas shifts at the skin surface and shifts of the center positions of skin-adhesive fiducials were measured quantitatively. Moreover, we present an illustrative case of an ultra-high-field image-guided skull base meningioma resection. We found excellent intracranial correspondence between 3- and 7-T MRI scans. However, the average maximum skin shift was 6.8 ± 2.0 mm in group A and 5.2 ± 0.9 mm in group B. The average maximum difference between the skin-adhesive fiducial positions was 5.6 ± 3.1 mm in group B. In our tumor resection case, the meningioma blood supply could be targeted early thanks to 7-T image guidance, which made subsequent tumor removal straightforward. There are no visible intracranial distortions in magnetization-prepared T1-weighted 7-T MRI cranial images. However, we found considerable extracranial shifts. These shifts render 7-T images unreliable for patient-to-image registration. We recommend performing patient-to-image registration on a routine (computed tomography scan or 3-T magnetic resonance) image and subsequently fusing the 7-T magnetic resonance image with the routine image on the image guidance machine, until this issue is resolved.
ISSN:1878-8750
1878-8769
DOI:10.1016/j.wneu.2019.02.028