Loading…
Determination of Persistent and Mobile Organic Contaminants (PMOCs) in Water by Mixed-Mode Liquid Chromatography–Tandem Mass Spectrometry
The presence of persistent and mobile organic contaminants (PMOC) in aquatic environments has become a matter of concern due to their ability of breaking through natural and anthropogenic barriers, even reaching drinking water. The presence of many of these compounds in surface and drinking water ha...
Saved in:
Published in: | Analytical chemistry (Washington) 2019-04, Vol.91 (8), p.5176-5183 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-a525t-55f5feecca4b93a37460ac00f4146ba5fb954c53445d0559c55fdfedee5587763 |
---|---|
cites | cdi_FETCH-LOGICAL-a525t-55f5feecca4b93a37460ac00f4146ba5fb954c53445d0559c55fdfedee5587763 |
container_end_page | 5183 |
container_issue | 8 |
container_start_page | 5176 |
container_title | Analytical chemistry (Washington) |
container_volume | 91 |
creator | Montes, Rosa Rodil, Rosario Cela, Rafael Quintana, José Benito |
description | The presence of persistent and mobile organic contaminants (PMOC) in aquatic environments has become a matter of concern due to their ability of breaking through natural and anthropogenic barriers, even reaching drinking water. The presence of many of these compounds in surface and drinking water has been reported in screening studies, but there is still a lack of analytical methods capable of quantifying them. Herein, we propose a method combining mixed-mode-solid-phase extraction (MM-SPE) as preconcentration technique and mixed-mode liquid chromatography (MMLC) coupled to tandem mass spectrometry as a determination technique for the quantitative determination of 23 target PMOCs in surface and drinking water samples. When compared to reversed-phase liquid chromatography, the MMLC protocol has proven to be superior in both retentive capabilities and peak shape for ionic compounds, while performing also well for neutrals. The overall method performance was satisfactory with limits of quantification under 50 ng L–1 for most of analytes in both surface and drinking water. The relative standard deviation was lower than 20%, and the average recovery was 78 and 80% in surface and drinking water, respectively. The method was applied to 15 water samples collected in Spain, where 17 out of the 23 target PMOCs were quantified in at least one sample. Among them, 6 chemicals (e.g., benzyltrimethylammonium) are reported and/or quantified here for the first time. |
doi_str_mv | 10.1021/acs.analchem.8b05792 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2196519561</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2216262698</sourcerecordid><originalsourceid>FETCH-LOGICAL-a525t-55f5feecca4b93a37460ac00f4146ba5fb954c53445d0559c55fdfedee5587763</originalsourceid><addsrcrecordid>eNp9kc1u1DAURi1ERYfCGyBkiU1ZZGo7cX6WKFBAmmgqUcQyunFuOq4Se2o7ErNj3yVvyJPg0Uy76KLy4i58vnOl-xHyjrMlZ4JfgPJLMDCqDU7LsmOyqMQLsuBSsCQvS_GSLBhjaSIKxk7Ja-9vGeOc8fwVOU1ZWeWVKBbk_jMGdJM2ELQ11A70Cp3XPqAJFExPG9vpEena3YDRitbWBNjjJnh6ftWsa_-RakN_QdTQbkcb_Rv7pLE90pW-m3VP642zEwR742C72f378_c6enGiDXhPf2xRhfiPwe3ekJMBRo9vj_OM_Lz8cl1_S1brr9_rT6sEpJAhkXKQA6JSkHVVCmmR5QwUY0PGs7wDOXSVzJRMs0z2TMpKxUA_YI8oZVkUeXpGzg_erbN3M_rQTtorHEcwaGffCl7lklcy5xH98AS9tbOLV4-U4LmIryojlR0o5az3Dod26_QEbtdy1u7LamNZ7UNZ7bGsGHt_lM_dhP1j6KGdCLADsI8_Ln7W-R-Ri6YI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2216262698</pqid></control><display><type>article</type><title>Determination of Persistent and Mobile Organic Contaminants (PMOCs) in Water by Mixed-Mode Liquid Chromatography–Tandem Mass Spectrometry</title><source>Access via American Chemical Society</source><creator>Montes, Rosa ; Rodil, Rosario ; Cela, Rafael ; Quintana, José Benito</creator><creatorcontrib>Montes, Rosa ; Rodil, Rosario ; Cela, Rafael ; Quintana, José Benito</creatorcontrib><description>The presence of persistent and mobile organic contaminants (PMOC) in aquatic environments has become a matter of concern due to their ability of breaking through natural and anthropogenic barriers, even reaching drinking water. The presence of many of these compounds in surface and drinking water has been reported in screening studies, but there is still a lack of analytical methods capable of quantifying them. Herein, we propose a method combining mixed-mode-solid-phase extraction (MM-SPE) as preconcentration technique and mixed-mode liquid chromatography (MMLC) coupled to tandem mass spectrometry as a determination technique for the quantitative determination of 23 target PMOCs in surface and drinking water samples. When compared to reversed-phase liquid chromatography, the MMLC protocol has proven to be superior in both retentive capabilities and peak shape for ionic compounds, while performing also well for neutrals. The overall method performance was satisfactory with limits of quantification under 50 ng L–1 for most of analytes in both surface and drinking water. The relative standard deviation was lower than 20%, and the average recovery was 78 and 80% in surface and drinking water, respectively. The method was applied to 15 water samples collected in Spain, where 17 out of the 23 target PMOCs were quantified in at least one sample. Among them, 6 chemicals (e.g., benzyltrimethylammonium) are reported and/or quantified here for the first time.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/acs.analchem.8b05792</identifier><identifier>PMID: 30896927</identifier><language>eng</language><publisher>United States: American Chemical Society</publisher><subject>Analytical chemistry ; Analytical methods ; Anthropogenic factors ; Aquatic environment ; Chemistry ; Chromatography ; Contaminants ; Coupled modes ; Drinking water ; Liquid chromatography ; Mass spectrometry ; Mass spectroscopy ; Organic chemistry ; Organic contaminants ; Scientific imaging ; Solid phases ; Spectroscopy ; Water analysis ; Water pollution ; Water sampling</subject><ispartof>Analytical chemistry (Washington), 2019-04, Vol.91 (8), p.5176-5183</ispartof><rights>Copyright American Chemical Society Apr 16, 2019</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a525t-55f5feecca4b93a37460ac00f4146ba5fb954c53445d0559c55fdfedee5587763</citedby><cites>FETCH-LOGICAL-a525t-55f5feecca4b93a37460ac00f4146ba5fb954c53445d0559c55fdfedee5587763</cites><orcidid>0000-0002-4154-3541 ; 0000-0002-2566-8133</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30896927$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Montes, Rosa</creatorcontrib><creatorcontrib>Rodil, Rosario</creatorcontrib><creatorcontrib>Cela, Rafael</creatorcontrib><creatorcontrib>Quintana, José Benito</creatorcontrib><title>Determination of Persistent and Mobile Organic Contaminants (PMOCs) in Water by Mixed-Mode Liquid Chromatography–Tandem Mass Spectrometry</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>The presence of persistent and mobile organic contaminants (PMOC) in aquatic environments has become a matter of concern due to their ability of breaking through natural and anthropogenic barriers, even reaching drinking water. The presence of many of these compounds in surface and drinking water has been reported in screening studies, but there is still a lack of analytical methods capable of quantifying them. Herein, we propose a method combining mixed-mode-solid-phase extraction (MM-SPE) as preconcentration technique and mixed-mode liquid chromatography (MMLC) coupled to tandem mass spectrometry as a determination technique for the quantitative determination of 23 target PMOCs in surface and drinking water samples. When compared to reversed-phase liquid chromatography, the MMLC protocol has proven to be superior in both retentive capabilities and peak shape for ionic compounds, while performing also well for neutrals. The overall method performance was satisfactory with limits of quantification under 50 ng L–1 for most of analytes in both surface and drinking water. The relative standard deviation was lower than 20%, and the average recovery was 78 and 80% in surface and drinking water, respectively. The method was applied to 15 water samples collected in Spain, where 17 out of the 23 target PMOCs were quantified in at least one sample. Among them, 6 chemicals (e.g., benzyltrimethylammonium) are reported and/or quantified here for the first time.</description><subject>Analytical chemistry</subject><subject>Analytical methods</subject><subject>Anthropogenic factors</subject><subject>Aquatic environment</subject><subject>Chemistry</subject><subject>Chromatography</subject><subject>Contaminants</subject><subject>Coupled modes</subject><subject>Drinking water</subject><subject>Liquid chromatography</subject><subject>Mass spectrometry</subject><subject>Mass spectroscopy</subject><subject>Organic chemistry</subject><subject>Organic contaminants</subject><subject>Scientific imaging</subject><subject>Solid phases</subject><subject>Spectroscopy</subject><subject>Water analysis</subject><subject>Water pollution</subject><subject>Water sampling</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp9kc1u1DAURi1ERYfCGyBkiU1ZZGo7cX6WKFBAmmgqUcQyunFuOq4Se2o7ErNj3yVvyJPg0Uy76KLy4i58vnOl-xHyjrMlZ4JfgPJLMDCqDU7LsmOyqMQLsuBSsCQvS_GSLBhjaSIKxk7Ja-9vGeOc8fwVOU1ZWeWVKBbk_jMGdJM2ELQ11A70Cp3XPqAJFExPG9vpEena3YDRitbWBNjjJnh6ftWsa_-RakN_QdTQbkcb_Rv7pLE90pW-m3VP642zEwR742C72f378_c6enGiDXhPf2xRhfiPwe3ekJMBRo9vj_OM_Lz8cl1_S1brr9_rT6sEpJAhkXKQA6JSkHVVCmmR5QwUY0PGs7wDOXSVzJRMs0z2TMpKxUA_YI8oZVkUeXpGzg_erbN3M_rQTtorHEcwaGffCl7lklcy5xH98AS9tbOLV4-U4LmIryojlR0o5az3Dod26_QEbtdy1u7LamNZ7UNZ7bGsGHt_lM_dhP1j6KGdCLADsI8_Ln7W-R-Ri6YI</recordid><startdate>20190416</startdate><enddate>20190416</enddate><creator>Montes, Rosa</creator><creator>Rodil, Rosario</creator><creator>Cela, Rafael</creator><creator>Quintana, José Benito</creator><general>American Chemical Society</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TM</scope><scope>7U5</scope><scope>7U7</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-4154-3541</orcidid><orcidid>https://orcid.org/0000-0002-2566-8133</orcidid></search><sort><creationdate>20190416</creationdate><title>Determination of Persistent and Mobile Organic Contaminants (PMOCs) in Water by Mixed-Mode Liquid Chromatography–Tandem Mass Spectrometry</title><author>Montes, Rosa ; Rodil, Rosario ; Cela, Rafael ; Quintana, José Benito</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a525t-55f5feecca4b93a37460ac00f4146ba5fb954c53445d0559c55fdfedee5587763</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Analytical chemistry</topic><topic>Analytical methods</topic><topic>Anthropogenic factors</topic><topic>Aquatic environment</topic><topic>Chemistry</topic><topic>Chromatography</topic><topic>Contaminants</topic><topic>Coupled modes</topic><topic>Drinking water</topic><topic>Liquid chromatography</topic><topic>Mass spectrometry</topic><topic>Mass spectroscopy</topic><topic>Organic chemistry</topic><topic>Organic contaminants</topic><topic>Scientific imaging</topic><topic>Solid phases</topic><topic>Spectroscopy</topic><topic>Water analysis</topic><topic>Water pollution</topic><topic>Water sampling</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Montes, Rosa</creatorcontrib><creatorcontrib>Rodil, Rosario</creatorcontrib><creatorcontrib>Cela, Rafael</creatorcontrib><creatorcontrib>Quintana, José Benito</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Montes, Rosa</au><au>Rodil, Rosario</au><au>Cela, Rafael</au><au>Quintana, José Benito</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of Persistent and Mobile Organic Contaminants (PMOCs) in Water by Mixed-Mode Liquid Chromatography–Tandem Mass Spectrometry</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>2019-04-16</date><risdate>2019</risdate><volume>91</volume><issue>8</issue><spage>5176</spage><epage>5183</epage><pages>5176-5183</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><abstract>The presence of persistent and mobile organic contaminants (PMOC) in aquatic environments has become a matter of concern due to their ability of breaking through natural and anthropogenic barriers, even reaching drinking water. The presence of many of these compounds in surface and drinking water has been reported in screening studies, but there is still a lack of analytical methods capable of quantifying them. Herein, we propose a method combining mixed-mode-solid-phase extraction (MM-SPE) as preconcentration technique and mixed-mode liquid chromatography (MMLC) coupled to tandem mass spectrometry as a determination technique for the quantitative determination of 23 target PMOCs in surface and drinking water samples. When compared to reversed-phase liquid chromatography, the MMLC protocol has proven to be superior in both retentive capabilities and peak shape for ionic compounds, while performing also well for neutrals. The overall method performance was satisfactory with limits of quantification under 50 ng L–1 for most of analytes in both surface and drinking water. The relative standard deviation was lower than 20%, and the average recovery was 78 and 80% in surface and drinking water, respectively. The method was applied to 15 water samples collected in Spain, where 17 out of the 23 target PMOCs were quantified in at least one sample. Among them, 6 chemicals (e.g., benzyltrimethylammonium) are reported and/or quantified here for the first time.</abstract><cop>United States</cop><pub>American Chemical Society</pub><pmid>30896927</pmid><doi>10.1021/acs.analchem.8b05792</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0002-4154-3541</orcidid><orcidid>https://orcid.org/0000-0002-2566-8133</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2700 |
ispartof | Analytical chemistry (Washington), 2019-04, Vol.91 (8), p.5176-5183 |
issn | 0003-2700 1520-6882 |
language | eng |
recordid | cdi_proquest_miscellaneous_2196519561 |
source | Access via American Chemical Society |
subjects | Analytical chemistry Analytical methods Anthropogenic factors Aquatic environment Chemistry Chromatography Contaminants Coupled modes Drinking water Liquid chromatography Mass spectrometry Mass spectroscopy Organic chemistry Organic contaminants Scientific imaging Solid phases Spectroscopy Water analysis Water pollution Water sampling |
title | Determination of Persistent and Mobile Organic Contaminants (PMOCs) in Water by Mixed-Mode Liquid Chromatography–Tandem Mass Spectrometry |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T21%3A36%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20Persistent%20and%20Mobile%20Organic%20Contaminants%20(PMOCs)%20in%20Water%20by%20Mixed-Mode%20Liquid%20Chromatography%E2%80%93Tandem%20Mass%20Spectrometry&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Montes,%20Rosa&rft.date=2019-04-16&rft.volume=91&rft.issue=8&rft.spage=5176&rft.epage=5183&rft.pages=5176-5183&rft.issn=0003-2700&rft.eissn=1520-6882&rft_id=info:doi/10.1021/acs.analchem.8b05792&rft_dat=%3Cproquest_cross%3E2216262698%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a525t-55f5feecca4b93a37460ac00f4146ba5fb954c53445d0559c55fdfedee5587763%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2216262698&rft_id=info:pmid/30896927&rfr_iscdi=true |