Loading…

Safety and efficacy of a simple cardiotomy suction system as a blood salvage procedure during off-pump coronary artery bypass surgery

The ideal blood-salvaging strategies for off-pump coronary artery bypass graft procedures have not been determined. We developed a new blood-salvaging system that uses a cardiotomy suction. The purpose of this study was to examine the efficacy of this novel method. This was a retrospective study inv...

Full description

Saved in:
Bibliographic Details
Published in:Journal of artificial organs 2019-09, Vol.22 (3), p.194-199
Main Authors: Yasukawa, Takashi, Manabe, Susumu, Hiraoka, Daisuke, Hirayama, Daiki, Kinoshita, Ryoji, Komori, Masami, Hosokawa, Masahiro, Hirooka, Kazunobu
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c464t-5a5bdec6d5dd340a5f97277e45dab9939c73560278bf1ea1f696eebb3ca4f0bb3
cites cdi_FETCH-LOGICAL-c464t-5a5bdec6d5dd340a5f97277e45dab9939c73560278bf1ea1f696eebb3ca4f0bb3
container_end_page 199
container_issue 3
container_start_page 194
container_title Journal of artificial organs
container_volume 22
creator Yasukawa, Takashi
Manabe, Susumu
Hiraoka, Daisuke
Hirayama, Daiki
Kinoshita, Ryoji
Komori, Masami
Hosokawa, Masahiro
Hirooka, Kazunobu
description The ideal blood-salvaging strategies for off-pump coronary artery bypass graft procedures have not been determined. We developed a new blood-salvaging system that uses a cardiotomy suction. The purpose of this study was to examine the efficacy of this novel method. This was a retrospective study involving 50 consecutive patients undergoing off-pump coronary artery bypass grafting. In 25 patients, a simple cardiotomy suction system was used (cardiotomy suction group). These individuals were compared with 25 historical cohorts who were treating with the conventional cell saver system (cell saver group). There was no in-hospital mortality in either group. In the cell saver group, there was one major complication (stroke) and two minor complications (saphenous vein graft occlusion, superficial wound infection). In the cardiotomy suction group, there was one minor complication (subclinical pulmonary emboli). The cardiotomy suction group received significantly fewer transfused RBC (cardiotomy: 0.56 ± 1.4 units vs. cell saver: 2.46 ± 3.3 units, p  = 0.005). The serum total protein and albumin levels were significantly higher in the cardiotomy group. Our newly developed simple cardiotomy suction system, when compared with the conventional cell saver system, produced similar clinical results and attenuated postoperative hemodilution. Our system may emerge as a preferable alternative for blood salvage during off-pump coronary artery bypass grafting.
doi_str_mv 10.1007/s10047-019-01103-9
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2207160648</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2205731755</sourcerecordid><originalsourceid>FETCH-LOGICAL-c464t-5a5bdec6d5dd340a5f97277e45dab9939c73560278bf1ea1f696eebb3ca4f0bb3</originalsourceid><addsrcrecordid>eNp9kcuKFTEQhoMozjj6Ai4k4MZNa-45WcrgDQZcqOuQTiqHHro7bdIt9AP43tbxjAouZpGqFHz1V1E_Ic85e80Zs28aRmU7xh0-zmTnHpBLbk6lY-oh_pVUnRXCXZAnrd0yxq227DG5kMyZg7Dykvz8EjKsOw1zopDzEEPcack00DZMywg0hpqGspZpp22L61Bm2va2wkRDQ6ofS0m0hfFHOAJdaomQtgoUwzAfUSl3yzYtNJZa5lBxUF0BU78voTWUrEcsn5JHOYwNnt3lK_Lt_buv1x-7m88fPl2_vemiMmrtdNB9gmiSTkkqFnR2VlgLSqfQOyddtFIbJuyhzxwCz8YZgL6XMajMMF-RV2ddXPT7Bm3109AijGOYoWzNC8EsN8yoA6Iv_0Nvy1Zn3A4p45TQ3Kr7KaatxItrpMSZirW0ViH7pQ4TXsNz5k9W-rOVHq30v630Dpte3Elv_QTpb8sf7xCQZ6Atp1tD_Tf7HtlfyUKrGg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2205731755</pqid></control><display><type>article</type><title>Safety and efficacy of a simple cardiotomy suction system as a blood salvage procedure during off-pump coronary artery bypass surgery</title><source>Springer Link</source><creator>Yasukawa, Takashi ; Manabe, Susumu ; Hiraoka, Daisuke ; Hirayama, Daiki ; Kinoshita, Ryoji ; Komori, Masami ; Hosokawa, Masahiro ; Hirooka, Kazunobu</creator><creatorcontrib>Yasukawa, Takashi ; Manabe, Susumu ; Hiraoka, Daisuke ; Hirayama, Daiki ; Kinoshita, Ryoji ; Komori, Masami ; Hosokawa, Masahiro ; Hirooka, Kazunobu</creatorcontrib><description>The ideal blood-salvaging strategies for off-pump coronary artery bypass graft procedures have not been determined. We developed a new blood-salvaging system that uses a cardiotomy suction. The purpose of this study was to examine the efficacy of this novel method. This was a retrospective study involving 50 consecutive patients undergoing off-pump coronary artery bypass grafting. In 25 patients, a simple cardiotomy suction system was used (cardiotomy suction group). These individuals were compared with 25 historical cohorts who were treating with the conventional cell saver system (cell saver group). There was no in-hospital mortality in either group. In the cell saver group, there was one major complication (stroke) and two minor complications (saphenous vein graft occlusion, superficial wound infection). In the cardiotomy suction group, there was one minor complication (subclinical pulmonary emboli). The cardiotomy suction group received significantly fewer transfused RBC (cardiotomy: 0.56 ± 1.4 units vs. cell saver: 2.46 ± 3.3 units, p  = 0.005). The serum total protein and albumin levels were significantly higher in the cardiotomy group. Our newly developed simple cardiotomy suction system, when compared with the conventional cell saver system, produced similar clinical results and attenuated postoperative hemodilution. Our system may emerge as a preferable alternative for blood salvage during off-pump coronary artery bypass grafting.</description><identifier>ISSN: 1434-7229</identifier><identifier>EISSN: 1619-0904</identifier><identifier>DOI: 10.1007/s10047-019-01103-9</identifier><identifier>PMID: 30968273</identifier><language>eng</language><publisher>Tokyo: Springer Japan</publisher><subject>Aged ; Biomedical Engineering and Bioengineering ; Blood ; Cardiac Surgery ; Complications ; Coronary artery ; Coronary Artery Bypass, Off-Pump - methods ; Coronary vessels ; Female ; Grafting ; Heart surgery ; Humans ; Male ; Medical malpractice ; Medicine ; Medicine &amp; Public Health ; Middle Aged ; Nephrology ; Occlusion ; Operative Blood Salvage - methods ; Original Article ; Patients ; Proteins ; Retrospective Studies ; Salvage ; Suction ; Suction - adverse effects ; Suction - methods ; Suctioning ; Surgery ; Treatment Outcome ; Veins &amp; arteries ; Wound infection</subject><ispartof>Journal of artificial organs, 2019-09, Vol.22 (3), p.194-199</ispartof><rights>The Japanese Society for Artificial Organs 2019</rights><rights>Journal of Artificial Organs is a copyright of Springer, (2019). All Rights Reserved.</rights><rights>Copyright Springer Nature B.V. 2019</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c464t-5a5bdec6d5dd340a5f97277e45dab9939c73560278bf1ea1f696eebb3ca4f0bb3</citedby><cites>FETCH-LOGICAL-c464t-5a5bdec6d5dd340a5f97277e45dab9939c73560278bf1ea1f696eebb3ca4f0bb3</cites><orcidid>0000-0002-0904-4806</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30968273$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Yasukawa, Takashi</creatorcontrib><creatorcontrib>Manabe, Susumu</creatorcontrib><creatorcontrib>Hiraoka, Daisuke</creatorcontrib><creatorcontrib>Hirayama, Daiki</creatorcontrib><creatorcontrib>Kinoshita, Ryoji</creatorcontrib><creatorcontrib>Komori, Masami</creatorcontrib><creatorcontrib>Hosokawa, Masahiro</creatorcontrib><creatorcontrib>Hirooka, Kazunobu</creatorcontrib><title>Safety and efficacy of a simple cardiotomy suction system as a blood salvage procedure during off-pump coronary artery bypass surgery</title><title>Journal of artificial organs</title><addtitle>J Artif Organs</addtitle><addtitle>J Artif Organs</addtitle><description>The ideal blood-salvaging strategies for off-pump coronary artery bypass graft procedures have not been determined. We developed a new blood-salvaging system that uses a cardiotomy suction. The purpose of this study was to examine the efficacy of this novel method. This was a retrospective study involving 50 consecutive patients undergoing off-pump coronary artery bypass grafting. In 25 patients, a simple cardiotomy suction system was used (cardiotomy suction group). These individuals were compared with 25 historical cohorts who were treating with the conventional cell saver system (cell saver group). There was no in-hospital mortality in either group. In the cell saver group, there was one major complication (stroke) and two minor complications (saphenous vein graft occlusion, superficial wound infection). In the cardiotomy suction group, there was one minor complication (subclinical pulmonary emboli). The cardiotomy suction group received significantly fewer transfused RBC (cardiotomy: 0.56 ± 1.4 units vs. cell saver: 2.46 ± 3.3 units, p  = 0.005). The serum total protein and albumin levels were significantly higher in the cardiotomy group. Our newly developed simple cardiotomy suction system, when compared with the conventional cell saver system, produced similar clinical results and attenuated postoperative hemodilution. Our system may emerge as a preferable alternative for blood salvage during off-pump coronary artery bypass grafting.</description><subject>Aged</subject><subject>Biomedical Engineering and Bioengineering</subject><subject>Blood</subject><subject>Cardiac Surgery</subject><subject>Complications</subject><subject>Coronary artery</subject><subject>Coronary Artery Bypass, Off-Pump - methods</subject><subject>Coronary vessels</subject><subject>Female</subject><subject>Grafting</subject><subject>Heart surgery</subject><subject>Humans</subject><subject>Male</subject><subject>Medical malpractice</subject><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Middle Aged</subject><subject>Nephrology</subject><subject>Occlusion</subject><subject>Operative Blood Salvage - methods</subject><subject>Original Article</subject><subject>Patients</subject><subject>Proteins</subject><subject>Retrospective Studies</subject><subject>Salvage</subject><subject>Suction</subject><subject>Suction - adverse effects</subject><subject>Suction - methods</subject><subject>Suctioning</subject><subject>Surgery</subject><subject>Treatment Outcome</subject><subject>Veins &amp; arteries</subject><subject>Wound infection</subject><issn>1434-7229</issn><issn>1619-0904</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp9kcuKFTEQhoMozjj6Ai4k4MZNa-45WcrgDQZcqOuQTiqHHro7bdIt9AP43tbxjAouZpGqFHz1V1E_Ic85e80Zs28aRmU7xh0-zmTnHpBLbk6lY-oh_pVUnRXCXZAnrd0yxq227DG5kMyZg7Dykvz8EjKsOw1zopDzEEPcack00DZMywg0hpqGspZpp22L61Bm2va2wkRDQ6ofS0m0hfFHOAJdaomQtgoUwzAfUSl3yzYtNJZa5lBxUF0BU78voTWUrEcsn5JHOYwNnt3lK_Lt_buv1x-7m88fPl2_vemiMmrtdNB9gmiSTkkqFnR2VlgLSqfQOyddtFIbJuyhzxwCz8YZgL6XMajMMF-RV2ddXPT7Bm3109AijGOYoWzNC8EsN8yoA6Iv_0Nvy1Zn3A4p45TQ3Kr7KaatxItrpMSZirW0ViH7pQ4TXsNz5k9W-rOVHq30v630Dpte3Elv_QTpb8sf7xCQZ6Atp1tD_Tf7HtlfyUKrGg</recordid><startdate>20190901</startdate><enddate>20190901</enddate><creator>Yasukawa, Takashi</creator><creator>Manabe, Susumu</creator><creator>Hiraoka, Daisuke</creator><creator>Hirayama, Daiki</creator><creator>Kinoshita, Ryoji</creator><creator>Komori, Masami</creator><creator>Hosokawa, Masahiro</creator><creator>Hirooka, Kazunobu</creator><general>Springer Japan</general><general>Springer Nature B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>K9.</scope><scope>NAPCQ</scope><scope>P64</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-0904-4806</orcidid></search><sort><creationdate>20190901</creationdate><title>Safety and efficacy of a simple cardiotomy suction system as a blood salvage procedure during off-pump coronary artery bypass surgery</title><author>Yasukawa, Takashi ; Manabe, Susumu ; Hiraoka, Daisuke ; Hirayama, Daiki ; Kinoshita, Ryoji ; Komori, Masami ; Hosokawa, Masahiro ; Hirooka, Kazunobu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c464t-5a5bdec6d5dd340a5f97277e45dab9939c73560278bf1ea1f696eebb3ca4f0bb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Aged</topic><topic>Biomedical Engineering and Bioengineering</topic><topic>Blood</topic><topic>Cardiac Surgery</topic><topic>Complications</topic><topic>Coronary artery</topic><topic>Coronary Artery Bypass, Off-Pump - methods</topic><topic>Coronary vessels</topic><topic>Female</topic><topic>Grafting</topic><topic>Heart surgery</topic><topic>Humans</topic><topic>Male</topic><topic>Medical malpractice</topic><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Middle Aged</topic><topic>Nephrology</topic><topic>Occlusion</topic><topic>Operative Blood Salvage - methods</topic><topic>Original Article</topic><topic>Patients</topic><topic>Proteins</topic><topic>Retrospective Studies</topic><topic>Salvage</topic><topic>Suction</topic><topic>Suction - adverse effects</topic><topic>Suction - methods</topic><topic>Suctioning</topic><topic>Surgery</topic><topic>Treatment Outcome</topic><topic>Veins &amp; arteries</topic><topic>Wound infection</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yasukawa, Takashi</creatorcontrib><creatorcontrib>Manabe, Susumu</creatorcontrib><creatorcontrib>Hiraoka, Daisuke</creatorcontrib><creatorcontrib>Hirayama, Daiki</creatorcontrib><creatorcontrib>Kinoshita, Ryoji</creatorcontrib><creatorcontrib>Komori, Masami</creatorcontrib><creatorcontrib>Hosokawa, Masahiro</creatorcontrib><creatorcontrib>Hirooka, Kazunobu</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of artificial organs</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yasukawa, Takashi</au><au>Manabe, Susumu</au><au>Hiraoka, Daisuke</au><au>Hirayama, Daiki</au><au>Kinoshita, Ryoji</au><au>Komori, Masami</au><au>Hosokawa, Masahiro</au><au>Hirooka, Kazunobu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Safety and efficacy of a simple cardiotomy suction system as a blood salvage procedure during off-pump coronary artery bypass surgery</atitle><jtitle>Journal of artificial organs</jtitle><stitle>J Artif Organs</stitle><addtitle>J Artif Organs</addtitle><date>2019-09-01</date><risdate>2019</risdate><volume>22</volume><issue>3</issue><spage>194</spage><epage>199</epage><pages>194-199</pages><issn>1434-7229</issn><eissn>1619-0904</eissn><abstract>The ideal blood-salvaging strategies for off-pump coronary artery bypass graft procedures have not been determined. We developed a new blood-salvaging system that uses a cardiotomy suction. The purpose of this study was to examine the efficacy of this novel method. This was a retrospective study involving 50 consecutive patients undergoing off-pump coronary artery bypass grafting. In 25 patients, a simple cardiotomy suction system was used (cardiotomy suction group). These individuals were compared with 25 historical cohorts who were treating with the conventional cell saver system (cell saver group). There was no in-hospital mortality in either group. In the cell saver group, there was one major complication (stroke) and two minor complications (saphenous vein graft occlusion, superficial wound infection). In the cardiotomy suction group, there was one minor complication (subclinical pulmonary emboli). The cardiotomy suction group received significantly fewer transfused RBC (cardiotomy: 0.56 ± 1.4 units vs. cell saver: 2.46 ± 3.3 units, p  = 0.005). The serum total protein and albumin levels were significantly higher in the cardiotomy group. Our newly developed simple cardiotomy suction system, when compared with the conventional cell saver system, produced similar clinical results and attenuated postoperative hemodilution. Our system may emerge as a preferable alternative for blood salvage during off-pump coronary artery bypass grafting.</abstract><cop>Tokyo</cop><pub>Springer Japan</pub><pmid>30968273</pmid><doi>10.1007/s10047-019-01103-9</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0002-0904-4806</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1434-7229
ispartof Journal of artificial organs, 2019-09, Vol.22 (3), p.194-199
issn 1434-7229
1619-0904
language eng
recordid cdi_proquest_miscellaneous_2207160648
source Springer Link
subjects Aged
Biomedical Engineering and Bioengineering
Blood
Cardiac Surgery
Complications
Coronary artery
Coronary Artery Bypass, Off-Pump - methods
Coronary vessels
Female
Grafting
Heart surgery
Humans
Male
Medical malpractice
Medicine
Medicine & Public Health
Middle Aged
Nephrology
Occlusion
Operative Blood Salvage - methods
Original Article
Patients
Proteins
Retrospective Studies
Salvage
Suction
Suction - adverse effects
Suction - methods
Suctioning
Surgery
Treatment Outcome
Veins & arteries
Wound infection
title Safety and efficacy of a simple cardiotomy suction system as a blood salvage procedure during off-pump coronary artery bypass surgery
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T03%3A57%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Safety%20and%20efficacy%20of%20a%20simple%20cardiotomy%20suction%20system%20as%20a%20blood%20salvage%20procedure%20during%20off-pump%20coronary%20artery%20bypass%20surgery&rft.jtitle=Journal%20of%20artificial%20organs&rft.au=Yasukawa,%20Takashi&rft.date=2019-09-01&rft.volume=22&rft.issue=3&rft.spage=194&rft.epage=199&rft.pages=194-199&rft.issn=1434-7229&rft.eissn=1619-0904&rft_id=info:doi/10.1007/s10047-019-01103-9&rft_dat=%3Cproquest_cross%3E2205731755%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c464t-5a5bdec6d5dd340a5f97277e45dab9939c73560278bf1ea1f696eebb3ca4f0bb3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2205731755&rft_id=info:pmid/30968273&rfr_iscdi=true