Loading…
OMERACT Hip Inflammation Magnetic Resonance Imaging Scoring System (HIMRISS) Assessment in Longitudinal Study
To assess reliability, feasibility, and responsiveness of Hip Inflammation Magnetic resonance imaging Scoring System (HIMRISS) for bone marrow lesions (BML) in hip osteoarthritis (OA). HIMRISS was scored by 8 readers in 360 hips of 90 patients imaged pre/post-hip steroid injection. Pre-scoring, new...
Saved in:
Published in: | Journal of rheumatology 2019-09, Vol.46 (9), p.1239-1242 |
---|---|
Main Authors: | , , , , , , , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c293t-df4ab1ec988a6b5e1ce5785d9908ffad441242d411bb4a4485a368bea5e30c4c3 |
---|---|
cites | cdi_FETCH-LOGICAL-c293t-df4ab1ec988a6b5e1ce5785d9908ffad441242d411bb4a4485a368bea5e30c4c3 |
container_end_page | 1242 |
container_issue | 9 |
container_start_page | 1239 |
container_title | Journal of rheumatology |
container_volume | 46 |
creator | Jaremko, Jacob L Lambert, Robert G W Pedersen, Susanne J Weber, Ulrich Lindsay, Duncan Al-Ani, Zeid Steer, Kieran Pianta, Marcus Wichuk, Stephanie Maksymowych, Walter P |
description | To assess reliability, feasibility, and responsiveness of Hip Inflammation Magnetic resonance imaging Scoring System (HIMRISS) for bone marrow lesions (BML) in hip osteoarthritis (OA).
HIMRISS was scored by 8 readers in 360 hips of 90 patients imaged pre/post-hip steroid injection. Pre-scoring, new readers trained online to achieve intraclass correlation coefficient (ICC) > 0.80 versus experts.
HIMRISS reliability was excellent for BML status (ICC 0.83-0.92). Despite small changes post-injection, reliability of BML change scores was high in femur (0.76-0.81) and moderate in acetabulum (0.42-0.56).
HIMRISS should be a priority for further assessment of hip BML in OA, and evaluated for use in other arthropathies. |
doi_str_mv | 10.3899/jrheum.181043 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2229129911</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2229129911</sourcerecordid><originalsourceid>FETCH-LOGICAL-c293t-df4ab1ec988a6b5e1ce5785d9908ffad441242d411bb4a4485a368bea5e30c4c3</originalsourceid><addsrcrecordid>eNo9kD1PwzAURS0EgvIxsiKPMAT8bCe1x6oqNFIrpBYktshxXopR7JQ4GfrvKRSY7h2OznAIuQZ2L5TWDx_dOw7-HhQwKY7ICKTWCR-n_JiMmIA0gYy_nZHzGD8Yg0xm6pScCTYesxTEiPjn5Ww1mb7QudvSPNSN8d70rg10aTYBe2fpCmMbTLBIc282Lmzo2rbdz-5ij57ezvPlKl-v7-gkRozRY-ipC3TRho3rh8oF09D1_uwuyUltmohXv3tBXh9nL9N5snh-yqeTRWK5Fn1S1dKUgFYrZbIyRbCYjlVaac1UXZtKSuCSVxKgLKWRUqVGZKpEk6JgVlpxQW4P3m3Xfg4Y-8K7aLFpTMB2iAXnXAPXGmCPJgfUdm2MHdbFtnPedLsCWPFduDgULg6F9_zNr3ooPVb_9F9S8QXbwHgz</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2229129911</pqid></control><display><type>article</type><title>OMERACT Hip Inflammation Magnetic Resonance Imaging Scoring System (HIMRISS) Assessment in Longitudinal Study</title><source>Freely Accessible Journals</source><creator>Jaremko, Jacob L ; Lambert, Robert G W ; Pedersen, Susanne J ; Weber, Ulrich ; Lindsay, Duncan ; Al-Ani, Zeid ; Steer, Kieran ; Pianta, Marcus ; Wichuk, Stephanie ; Maksymowych, Walter P</creator><creatorcontrib>Jaremko, Jacob L ; Lambert, Robert G W ; Pedersen, Susanne J ; Weber, Ulrich ; Lindsay, Duncan ; Al-Ani, Zeid ; Steer, Kieran ; Pianta, Marcus ; Wichuk, Stephanie ; Maksymowych, Walter P</creatorcontrib><description>To assess reliability, feasibility, and responsiveness of Hip Inflammation Magnetic resonance imaging Scoring System (HIMRISS) for bone marrow lesions (BML) in hip osteoarthritis (OA).
HIMRISS was scored by 8 readers in 360 hips of 90 patients imaged pre/post-hip steroid injection. Pre-scoring, new readers trained online to achieve intraclass correlation coefficient (ICC) > 0.80 versus experts.
HIMRISS reliability was excellent for BML status (ICC 0.83-0.92). Despite small changes post-injection, reliability of BML change scores was high in femur (0.76-0.81) and moderate in acetabulum (0.42-0.56).
HIMRISS should be a priority for further assessment of hip BML in OA, and evaluated for use in other arthropathies.</description><identifier>ISSN: 0315-162X</identifier><identifier>EISSN: 1499-2752</identifier><identifier>DOI: 10.3899/jrheum.181043</identifier><identifier>PMID: 30770513</identifier><language>eng</language><publisher>Canada</publisher><ispartof>Journal of rheumatology, 2019-09, Vol.46 (9), p.1239-1242</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c293t-df4ab1ec988a6b5e1ce5785d9908ffad441242d411bb4a4485a368bea5e30c4c3</citedby><cites>FETCH-LOGICAL-c293t-df4ab1ec988a6b5e1ce5785d9908ffad441242d411bb4a4485a368bea5e30c4c3</cites><orcidid>0000-0003-0305-3290 ; 0000-0002-6500-9263</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30770513$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Jaremko, Jacob L</creatorcontrib><creatorcontrib>Lambert, Robert G W</creatorcontrib><creatorcontrib>Pedersen, Susanne J</creatorcontrib><creatorcontrib>Weber, Ulrich</creatorcontrib><creatorcontrib>Lindsay, Duncan</creatorcontrib><creatorcontrib>Al-Ani, Zeid</creatorcontrib><creatorcontrib>Steer, Kieran</creatorcontrib><creatorcontrib>Pianta, Marcus</creatorcontrib><creatorcontrib>Wichuk, Stephanie</creatorcontrib><creatorcontrib>Maksymowych, Walter P</creatorcontrib><title>OMERACT Hip Inflammation Magnetic Resonance Imaging Scoring System (HIMRISS) Assessment in Longitudinal Study</title><title>Journal of rheumatology</title><addtitle>J Rheumatol</addtitle><description>To assess reliability, feasibility, and responsiveness of Hip Inflammation Magnetic resonance imaging Scoring System (HIMRISS) for bone marrow lesions (BML) in hip osteoarthritis (OA).
HIMRISS was scored by 8 readers in 360 hips of 90 patients imaged pre/post-hip steroid injection. Pre-scoring, new readers trained online to achieve intraclass correlation coefficient (ICC) > 0.80 versus experts.
HIMRISS reliability was excellent for BML status (ICC 0.83-0.92). Despite small changes post-injection, reliability of BML change scores was high in femur (0.76-0.81) and moderate in acetabulum (0.42-0.56).
HIMRISS should be a priority for further assessment of hip BML in OA, and evaluated for use in other arthropathies.</description><issn>0315-162X</issn><issn>1499-2752</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNo9kD1PwzAURS0EgvIxsiKPMAT8bCe1x6oqNFIrpBYktshxXopR7JQ4GfrvKRSY7h2OznAIuQZ2L5TWDx_dOw7-HhQwKY7ICKTWCR-n_JiMmIA0gYy_nZHzGD8Yg0xm6pScCTYesxTEiPjn5Ww1mb7QudvSPNSN8d70rg10aTYBe2fpCmMbTLBIc282Lmzo2rbdz-5ij57ezvPlKl-v7-gkRozRY-ipC3TRho3rh8oF09D1_uwuyUltmohXv3tBXh9nL9N5snh-yqeTRWK5Fn1S1dKUgFYrZbIyRbCYjlVaac1UXZtKSuCSVxKgLKWRUqVGZKpEk6JgVlpxQW4P3m3Xfg4Y-8K7aLFpTMB2iAXnXAPXGmCPJgfUdm2MHdbFtnPedLsCWPFduDgULg6F9_zNr3ooPVb_9F9S8QXbwHgz</recordid><startdate>201909</startdate><enddate>201909</enddate><creator>Jaremko, Jacob L</creator><creator>Lambert, Robert G W</creator><creator>Pedersen, Susanne J</creator><creator>Weber, Ulrich</creator><creator>Lindsay, Duncan</creator><creator>Al-Ani, Zeid</creator><creator>Steer, Kieran</creator><creator>Pianta, Marcus</creator><creator>Wichuk, Stephanie</creator><creator>Maksymowych, Walter P</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-0305-3290</orcidid><orcidid>https://orcid.org/0000-0002-6500-9263</orcidid></search><sort><creationdate>201909</creationdate><title>OMERACT Hip Inflammation Magnetic Resonance Imaging Scoring System (HIMRISS) Assessment in Longitudinal Study</title><author>Jaremko, Jacob L ; Lambert, Robert G W ; Pedersen, Susanne J ; Weber, Ulrich ; Lindsay, Duncan ; Al-Ani, Zeid ; Steer, Kieran ; Pianta, Marcus ; Wichuk, Stephanie ; Maksymowych, Walter P</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c293t-df4ab1ec988a6b5e1ce5785d9908ffad441242d411bb4a4485a368bea5e30c4c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jaremko, Jacob L</creatorcontrib><creatorcontrib>Lambert, Robert G W</creatorcontrib><creatorcontrib>Pedersen, Susanne J</creatorcontrib><creatorcontrib>Weber, Ulrich</creatorcontrib><creatorcontrib>Lindsay, Duncan</creatorcontrib><creatorcontrib>Al-Ani, Zeid</creatorcontrib><creatorcontrib>Steer, Kieran</creatorcontrib><creatorcontrib>Pianta, Marcus</creatorcontrib><creatorcontrib>Wichuk, Stephanie</creatorcontrib><creatorcontrib>Maksymowych, Walter P</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of rheumatology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jaremko, Jacob L</au><au>Lambert, Robert G W</au><au>Pedersen, Susanne J</au><au>Weber, Ulrich</au><au>Lindsay, Duncan</au><au>Al-Ani, Zeid</au><au>Steer, Kieran</au><au>Pianta, Marcus</au><au>Wichuk, Stephanie</au><au>Maksymowych, Walter P</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>OMERACT Hip Inflammation Magnetic Resonance Imaging Scoring System (HIMRISS) Assessment in Longitudinal Study</atitle><jtitle>Journal of rheumatology</jtitle><addtitle>J Rheumatol</addtitle><date>2019-09</date><risdate>2019</risdate><volume>46</volume><issue>9</issue><spage>1239</spage><epage>1242</epage><pages>1239-1242</pages><issn>0315-162X</issn><eissn>1499-2752</eissn><abstract>To assess reliability, feasibility, and responsiveness of Hip Inflammation Magnetic resonance imaging Scoring System (HIMRISS) for bone marrow lesions (BML) in hip osteoarthritis (OA).
HIMRISS was scored by 8 readers in 360 hips of 90 patients imaged pre/post-hip steroid injection. Pre-scoring, new readers trained online to achieve intraclass correlation coefficient (ICC) > 0.80 versus experts.
HIMRISS reliability was excellent for BML status (ICC 0.83-0.92). Despite small changes post-injection, reliability of BML change scores was high in femur (0.76-0.81) and moderate in acetabulum (0.42-0.56).
HIMRISS should be a priority for further assessment of hip BML in OA, and evaluated for use in other arthropathies.</abstract><cop>Canada</cop><pmid>30770513</pmid><doi>10.3899/jrheum.181043</doi><tpages>4</tpages><orcidid>https://orcid.org/0000-0003-0305-3290</orcidid><orcidid>https://orcid.org/0000-0002-6500-9263</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0315-162X |
ispartof | Journal of rheumatology, 2019-09, Vol.46 (9), p.1239-1242 |
issn | 0315-162X 1499-2752 |
language | eng |
recordid | cdi_proquest_miscellaneous_2229129911 |
source | Freely Accessible Journals |
title | OMERACT Hip Inflammation Magnetic Resonance Imaging Scoring System (HIMRISS) Assessment in Longitudinal Study |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T21%3A27%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=OMERACT%20Hip%20Inflammation%20Magnetic%20Resonance%20Imaging%20Scoring%20System%20(HIMRISS)%20Assessment%20in%20Longitudinal%20Study&rft.jtitle=Journal%20of%20rheumatology&rft.au=Jaremko,%20Jacob%20L&rft.date=2019-09&rft.volume=46&rft.issue=9&rft.spage=1239&rft.epage=1242&rft.pages=1239-1242&rft.issn=0315-162X&rft.eissn=1499-2752&rft_id=info:doi/10.3899/jrheum.181043&rft_dat=%3Cproquest_cross%3E2229129911%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c293t-df4ab1ec988a6b5e1ce5785d9908ffad441242d411bb4a4485a368bea5e30c4c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2229129911&rft_id=info:pmid/30770513&rfr_iscdi=true |