Loading…

Fluoride removal from natural volcanic underground water by an electrocoagulation process: Parametric and cost evaluations

Excessive fluoride content in groundwater can cause serious risks to human health, and sources of groundwater intended for human consumption should be treated to reduce fluoride concentrations down to acceptable levels. In the particular case of the island of Tenerife (Canary Islands, Spain), the wa...

Full description

Saved in:
Bibliographic Details
Published in:Journal of environmental management 2019-09, Vol.246, p.472-483
Main Authors: Mena, V.F., Betancor-Abreu, A., González, S., Delgado, S., Souto, R.M., Santana, J.J.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c412t-954ca1da5c9abe36008732cc8110a78a5c2249549e09f22d730f3a9b94763dbf3
cites cdi_FETCH-LOGICAL-c412t-954ca1da5c9abe36008732cc8110a78a5c2249549e09f22d730f3a9b94763dbf3
container_end_page 483
container_issue
container_start_page 472
container_title Journal of environmental management
container_volume 246
creator Mena, V.F.
Betancor-Abreu, A.
González, S.
Delgado, S.
Souto, R.M.
Santana, J.J.
description Excessive fluoride content in groundwater can cause serious risks to human health, and sources of groundwater intended for human consumption should be treated to reduce fluoride concentrations down to acceptable levels. In the particular case of the island of Tenerife (Canary Islands, Spain), the water supply comes mainly from aquifers of volcanic origin with a high content of fluorides that make them unacceptable for human consumption without prior conditioning treatment. The treatments that generate a high rejection of water are not acceptable because water is a scarce natural resource of high value. An electrocoagulation process was investigated as a method to treat natural groundwater from volcanic soils containing a hazardously high fluoride content. The operating parameters of an electrocoagulation reactor model with parallel plate aluminum electrodes were optimized for batch and continuous flow operations. In the case of the batch operation, acidification of the water improved the removal efficiency of fluoride, which was the highest at pH 3. However, operation at the natural pH of the water achieved elimination efficiencies between 82 and 92%, depending on the applied current density. An optimum current density of 5 mA/cm2 was found in terms of maximum removal efficiency, and the kinetics of fluoride removal conformed to pseudo-second-order kinetics. In the continuous-flow operation, with the optimal residence time of 10 min and a separation of 0.5 cm between the electrodes, it was observed that the current density that would be applied would depend on the initial concentration of fluoride in the raw water. Thus, an initial fluoride concentration of 6.02 mg/L required a current density >7.5 mA/cm2 to comply with the legal guidelines in the product water, while for an initial concentration of 8.98 mg/L, the optimal current density was 10 mA/cm2. Under these operating conditions, the electrocoagulation process was able to reduce the fluoride concentration of natural groundwater to below 1.5 mg/L according to WHO guidelines with an operating cost between 0.20 and 0.26 €/m3 of treated water. [Display omitted] •Use of electrocoagulation technique for the remediation of fluoride in groundwater.•Performance intensification ways and cost evaluation are comprehensively discussed.•Operating conditions have been optimized in batch and continuous-flow regimes.•Percentage of fluoride removal varied between 68.9 and 84.7%.•Final fluoride concentration below the
doi_str_mv 10.1016/j.jenvman.2019.05.147
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2242153552</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0301479719307753</els_id><sourcerecordid>2242153552</sourcerecordid><originalsourceid>FETCH-LOGICAL-c412t-954ca1da5c9abe36008732cc8110a78a5c2249549e09f22d730f3a9b94763dbf3</originalsourceid><addsrcrecordid>eNqFkMFu1DAQhi1URJfCI1D52EvC2I43MReEKhaQKsEBztbEmVReJXZrJ4vK0-OyS689jcb6fv_2x9g7AbUAsX2_r_cUDjOGWoIwNehaNO0LthFgdNVtFZyxDSgQVdOa9py9znkPAEqK9hU7V0ICiE5s2J_dtMbkB-KJ5njAiY8pzjzgsqayHOLkMHjH1zBQuk2xTP4bF0q8f-AYOE3klhRdxNt1wsXHwO_KSjl_4D8w4UxLKnEsMRfzwqlUrP-4_Ia9HHHK9PY0L9iv3eef11-rm-9fvl1_uqlcI-RSGd04FANqZ7AntQXoWiWd64QAbLtyLmVTIENgRimHVsGo0PSmabdq6Ed1wa6O95aH3a-UFzv77GiaMFBcsy1xKbTSWhZUH1GXYs6JRnuX_IzpwQqwj9rt3p6020ftFrQt2kvu8lSx9jMNT6n_ngvw8QhQ-ejBU7LZeQqOBp-KQDtE_0zFX9LfmPU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2242153552</pqid></control><display><type>article</type><title>Fluoride removal from natural volcanic underground water by an electrocoagulation process: Parametric and cost evaluations</title><source>Elsevier</source><creator>Mena, V.F. ; Betancor-Abreu, A. ; González, S. ; Delgado, S. ; Souto, R.M. ; Santana, J.J.</creator><creatorcontrib>Mena, V.F. ; Betancor-Abreu, A. ; González, S. ; Delgado, S. ; Souto, R.M. ; Santana, J.J.</creatorcontrib><description>Excessive fluoride content in groundwater can cause serious risks to human health, and sources of groundwater intended for human consumption should be treated to reduce fluoride concentrations down to acceptable levels. In the particular case of the island of Tenerife (Canary Islands, Spain), the water supply comes mainly from aquifers of volcanic origin with a high content of fluorides that make them unacceptable for human consumption without prior conditioning treatment. The treatments that generate a high rejection of water are not acceptable because water is a scarce natural resource of high value. An electrocoagulation process was investigated as a method to treat natural groundwater from volcanic soils containing a hazardously high fluoride content. The operating parameters of an electrocoagulation reactor model with parallel plate aluminum electrodes were optimized for batch and continuous flow operations. In the case of the batch operation, acidification of the water improved the removal efficiency of fluoride, which was the highest at pH 3. However, operation at the natural pH of the water achieved elimination efficiencies between 82 and 92%, depending on the applied current density. An optimum current density of 5 mA/cm2 was found in terms of maximum removal efficiency, and the kinetics of fluoride removal conformed to pseudo-second-order kinetics. In the continuous-flow operation, with the optimal residence time of 10 min and a separation of 0.5 cm between the electrodes, it was observed that the current density that would be applied would depend on the initial concentration of fluoride in the raw water. Thus, an initial fluoride concentration of 6.02 mg/L required a current density &gt;7.5 mA/cm2 to comply with the legal guidelines in the product water, while for an initial concentration of 8.98 mg/L, the optimal current density was 10 mA/cm2. Under these operating conditions, the electrocoagulation process was able to reduce the fluoride concentration of natural groundwater to below 1.5 mg/L according to WHO guidelines with an operating cost between 0.20 and 0.26 €/m3 of treated water. [Display omitted] •Use of electrocoagulation technique for the remediation of fluoride in groundwater.•Performance intensification ways and cost evaluation are comprehensively discussed.•Operating conditions have been optimized in batch and continuous-flow regimes.•Percentage of fluoride removal varied between 68.9 and 84.7%.•Final fluoride concentration below the legal limit of 1.5 mg/L in all cases.</description><identifier>ISSN: 0301-4797</identifier><identifier>EISSN: 1095-8630</identifier><identifier>DOI: 10.1016/j.jenvman.2019.05.147</identifier><identifier>PMID: 31200181</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Aluminum electrodes ; Electrocoagulation process ; Fluoride removal ; Water treatment</subject><ispartof>Journal of environmental management, 2019-09, Vol.246, p.472-483</ispartof><rights>2019 Elsevier Ltd</rights><rights>Copyright © 2019 Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c412t-954ca1da5c9abe36008732cc8110a78a5c2249549e09f22d730f3a9b94763dbf3</citedby><cites>FETCH-LOGICAL-c412t-954ca1da5c9abe36008732cc8110a78a5c2249549e09f22d730f3a9b94763dbf3</cites><orcidid>0000-0001-9429-5513 ; 0000-0002-3030-2195</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31200181$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mena, V.F.</creatorcontrib><creatorcontrib>Betancor-Abreu, A.</creatorcontrib><creatorcontrib>González, S.</creatorcontrib><creatorcontrib>Delgado, S.</creatorcontrib><creatorcontrib>Souto, R.M.</creatorcontrib><creatorcontrib>Santana, J.J.</creatorcontrib><title>Fluoride removal from natural volcanic underground water by an electrocoagulation process: Parametric and cost evaluations</title><title>Journal of environmental management</title><addtitle>J Environ Manage</addtitle><description>Excessive fluoride content in groundwater can cause serious risks to human health, and sources of groundwater intended for human consumption should be treated to reduce fluoride concentrations down to acceptable levels. In the particular case of the island of Tenerife (Canary Islands, Spain), the water supply comes mainly from aquifers of volcanic origin with a high content of fluorides that make them unacceptable for human consumption without prior conditioning treatment. The treatments that generate a high rejection of water are not acceptable because water is a scarce natural resource of high value. An electrocoagulation process was investigated as a method to treat natural groundwater from volcanic soils containing a hazardously high fluoride content. The operating parameters of an electrocoagulation reactor model with parallel plate aluminum electrodes were optimized for batch and continuous flow operations. In the case of the batch operation, acidification of the water improved the removal efficiency of fluoride, which was the highest at pH 3. However, operation at the natural pH of the water achieved elimination efficiencies between 82 and 92%, depending on the applied current density. An optimum current density of 5 mA/cm2 was found in terms of maximum removal efficiency, and the kinetics of fluoride removal conformed to pseudo-second-order kinetics. In the continuous-flow operation, with the optimal residence time of 10 min and a separation of 0.5 cm between the electrodes, it was observed that the current density that would be applied would depend on the initial concentration of fluoride in the raw water. Thus, an initial fluoride concentration of 6.02 mg/L required a current density &gt;7.5 mA/cm2 to comply with the legal guidelines in the product water, while for an initial concentration of 8.98 mg/L, the optimal current density was 10 mA/cm2. Under these operating conditions, the electrocoagulation process was able to reduce the fluoride concentration of natural groundwater to below 1.5 mg/L according to WHO guidelines with an operating cost between 0.20 and 0.26 €/m3 of treated water. [Display omitted] •Use of electrocoagulation technique for the remediation of fluoride in groundwater.•Performance intensification ways and cost evaluation are comprehensively discussed.•Operating conditions have been optimized in batch and continuous-flow regimes.•Percentage of fluoride removal varied between 68.9 and 84.7%.•Final fluoride concentration below the legal limit of 1.5 mg/L in all cases.</description><subject>Aluminum electrodes</subject><subject>Electrocoagulation process</subject><subject>Fluoride removal</subject><subject>Water treatment</subject><issn>0301-4797</issn><issn>1095-8630</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNqFkMFu1DAQhi1URJfCI1D52EvC2I43MReEKhaQKsEBztbEmVReJXZrJ4vK0-OyS689jcb6fv_2x9g7AbUAsX2_r_cUDjOGWoIwNehaNO0LthFgdNVtFZyxDSgQVdOa9py9znkPAEqK9hU7V0ICiE5s2J_dtMbkB-KJ5njAiY8pzjzgsqayHOLkMHjH1zBQuk2xTP4bF0q8f-AYOE3klhRdxNt1wsXHwO_KSjl_4D8w4UxLKnEsMRfzwqlUrP-4_Ia9HHHK9PY0L9iv3eef11-rm-9fvl1_uqlcI-RSGd04FANqZ7AntQXoWiWd64QAbLtyLmVTIENgRimHVsGo0PSmabdq6Ed1wa6O95aH3a-UFzv77GiaMFBcsy1xKbTSWhZUH1GXYs6JRnuX_IzpwQqwj9rt3p6020ftFrQt2kvu8lSx9jMNT6n_ngvw8QhQ-ejBU7LZeQqOBp-KQDtE_0zFX9LfmPU</recordid><startdate>20190915</startdate><enddate>20190915</enddate><creator>Mena, V.F.</creator><creator>Betancor-Abreu, A.</creator><creator>González, S.</creator><creator>Delgado, S.</creator><creator>Souto, R.M.</creator><creator>Santana, J.J.</creator><general>Elsevier Ltd</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-9429-5513</orcidid><orcidid>https://orcid.org/0000-0002-3030-2195</orcidid></search><sort><creationdate>20190915</creationdate><title>Fluoride removal from natural volcanic underground water by an electrocoagulation process: Parametric and cost evaluations</title><author>Mena, V.F. ; Betancor-Abreu, A. ; González, S. ; Delgado, S. ; Souto, R.M. ; Santana, J.J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c412t-954ca1da5c9abe36008732cc8110a78a5c2249549e09f22d730f3a9b94763dbf3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Aluminum electrodes</topic><topic>Electrocoagulation process</topic><topic>Fluoride removal</topic><topic>Water treatment</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mena, V.F.</creatorcontrib><creatorcontrib>Betancor-Abreu, A.</creatorcontrib><creatorcontrib>González, S.</creatorcontrib><creatorcontrib>Delgado, S.</creatorcontrib><creatorcontrib>Souto, R.M.</creatorcontrib><creatorcontrib>Santana, J.J.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of environmental management</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mena, V.F.</au><au>Betancor-Abreu, A.</au><au>González, S.</au><au>Delgado, S.</au><au>Souto, R.M.</au><au>Santana, J.J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fluoride removal from natural volcanic underground water by an electrocoagulation process: Parametric and cost evaluations</atitle><jtitle>Journal of environmental management</jtitle><addtitle>J Environ Manage</addtitle><date>2019-09-15</date><risdate>2019</risdate><volume>246</volume><spage>472</spage><epage>483</epage><pages>472-483</pages><issn>0301-4797</issn><eissn>1095-8630</eissn><abstract>Excessive fluoride content in groundwater can cause serious risks to human health, and sources of groundwater intended for human consumption should be treated to reduce fluoride concentrations down to acceptable levels. In the particular case of the island of Tenerife (Canary Islands, Spain), the water supply comes mainly from aquifers of volcanic origin with a high content of fluorides that make them unacceptable for human consumption without prior conditioning treatment. The treatments that generate a high rejection of water are not acceptable because water is a scarce natural resource of high value. An electrocoagulation process was investigated as a method to treat natural groundwater from volcanic soils containing a hazardously high fluoride content. The operating parameters of an electrocoagulation reactor model with parallel plate aluminum electrodes were optimized for batch and continuous flow operations. In the case of the batch operation, acidification of the water improved the removal efficiency of fluoride, which was the highest at pH 3. However, operation at the natural pH of the water achieved elimination efficiencies between 82 and 92%, depending on the applied current density. An optimum current density of 5 mA/cm2 was found in terms of maximum removal efficiency, and the kinetics of fluoride removal conformed to pseudo-second-order kinetics. In the continuous-flow operation, with the optimal residence time of 10 min and a separation of 0.5 cm between the electrodes, it was observed that the current density that would be applied would depend on the initial concentration of fluoride in the raw water. Thus, an initial fluoride concentration of 6.02 mg/L required a current density &gt;7.5 mA/cm2 to comply with the legal guidelines in the product water, while for an initial concentration of 8.98 mg/L, the optimal current density was 10 mA/cm2. Under these operating conditions, the electrocoagulation process was able to reduce the fluoride concentration of natural groundwater to below 1.5 mg/L according to WHO guidelines with an operating cost between 0.20 and 0.26 €/m3 of treated water. [Display omitted] •Use of electrocoagulation technique for the remediation of fluoride in groundwater.•Performance intensification ways and cost evaluation are comprehensively discussed.•Operating conditions have been optimized in batch and continuous-flow regimes.•Percentage of fluoride removal varied between 68.9 and 84.7%.•Final fluoride concentration below the legal limit of 1.5 mg/L in all cases.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>31200181</pmid><doi>10.1016/j.jenvman.2019.05.147</doi><tpages>12</tpages><orcidid>https://orcid.org/0000-0001-9429-5513</orcidid><orcidid>https://orcid.org/0000-0002-3030-2195</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0301-4797
ispartof Journal of environmental management, 2019-09, Vol.246, p.472-483
issn 0301-4797
1095-8630
language eng
recordid cdi_proquest_miscellaneous_2242153552
source Elsevier
subjects Aluminum electrodes
Electrocoagulation process
Fluoride removal
Water treatment
title Fluoride removal from natural volcanic underground water by an electrocoagulation process: Parametric and cost evaluations
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T16%3A40%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fluoride%20removal%20from%20natural%20volcanic%20underground%20water%20by%20an%20electrocoagulation%20process:%20Parametric%20and%20cost%20evaluations&rft.jtitle=Journal%20of%20environmental%20management&rft.au=Mena,%20V.F.&rft.date=2019-09-15&rft.volume=246&rft.spage=472&rft.epage=483&rft.pages=472-483&rft.issn=0301-4797&rft.eissn=1095-8630&rft_id=info:doi/10.1016/j.jenvman.2019.05.147&rft_dat=%3Cproquest_cross%3E2242153552%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c412t-954ca1da5c9abe36008732cc8110a78a5c2249549e09f22d730f3a9b94763dbf3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2242153552&rft_id=info:pmid/31200181&rfr_iscdi=true