Loading…
Performance Evaluation And Modeling Of The Activated Sludge System Used In Riqqa, Kuwait
The wastewater treatment plant (WWTP) located in Riqqa, Kuwait, has shown signs of instability. The chemical oxygen demand (COD) in the secondary effluent COD was found to be particularly unstable (fluctuating sharply between 30 and 200 mg/l). This paper presents the performance evaluation conducted...
Saved in:
Published in: | WIT Transactions on Ecology and the Environment 2012-01, Vol.164, p.369 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The wastewater treatment plant (WWTP) located in Riqqa, Kuwait, has shown signs of instability. The chemical oxygen demand (COD) in the secondary effluent COD was found to be particularly unstable (fluctuating sharply between 30 and 200 mg/l). This paper presents the performance evaluation conducted by the Kuwait Institute for Scientific Research (KISR) of the activated sludge system, at Riqqa plant. Probable causes are indentified, and a mathematical model is developed. In addition to the system performance records for 2004– 2007, the results of a sampling campaign conducted from March 2009 to March 2010 were also used in the evaluation of the activated sludge system, based on influent and effluent qualities and common operating variables, e.g., hydraulic retention time (HRT), solids retention time (SRT), volumetric organic load (Lv) and food-to-microorganism ratio (F/M). The system was then modeled in a SIMBA platform, using Activated Sludge Model No. 1 (ASM1). The results obtained results indicated that the quantity and degree of biodegradability, i.e. biological oxygen demand-to-chemical oxygen demand ration (BOD/COD) of the wastewater being treated fluctuated greatly, probably due to the illegal discharge of industrial wastewaters or septage. The system, which is controlled manually, was repeatedly being operated outside optimal ranges. To maintain a high quality of treatment, it is recommended that automatic flow controllers be installed in recirculated activated sludge (RAS) and wasted activated sludge (WAS) streams, and that protective strategies be implemented to prevent the discharge of industrial and other toxic or inhibitory substances into the system. The developed model can be used to control and optimize the performance of the system. |
---|---|
ISSN: | 1746-448X 1743-3541 |
DOI: | 10.2495/WP120321 |