Loading…

Synthetic CT reconstruction using a deep spatial pyramid convolutional framework for MR‐only breast radiotherapy

Purpose The superior soft‐tissue contrast achieved using magnetic resonance imaging (MRI) compared to x‐ray computed tomography (CT) has led to the popularization of MRI‐guided radiation therapy (MR‐IGRT), especially in recent years with the advent of first and second generation MRI‐based therapy de...

Full description

Saved in:
Bibliographic Details
Published in:Medical physics (Lancaster) 2019-09, Vol.46 (9), p.4135-4147
Main Authors: Olberg, Sven, Zhang, Hao, Kennedy, William R., Chun, Jaehee, Rodriguez, Vivian, Zoberi, Imran, Thomas, Maria A., Kim, Jin Sung, Mutic, Sasa, Green, Olga L., Park, Justin C.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c3216-4d31fb7fae2001ca3fb565c9af89a2fc134af9c6d6bafc712060edc91dd6fe453
cites cdi_FETCH-LOGICAL-c3216-4d31fb7fae2001ca3fb565c9af89a2fc134af9c6d6bafc712060edc91dd6fe453
container_end_page 4147
container_issue 9
container_start_page 4135
container_title Medical physics (Lancaster)
container_volume 46
creator Olberg, Sven
Zhang, Hao
Kennedy, William R.
Chun, Jaehee
Rodriguez, Vivian
Zoberi, Imran
Thomas, Maria A.
Kim, Jin Sung
Mutic, Sasa
Green, Olga L.
Park, Justin C.
description Purpose The superior soft‐tissue contrast achieved using magnetic resonance imaging (MRI) compared to x‐ray computed tomography (CT) has led to the popularization of MRI‐guided radiation therapy (MR‐IGRT), especially in recent years with the advent of first and second generation MRI‐based therapy delivery systems for MR‐IGRT. The expanding use of these systems is driving interest in MRI‐only RT workflows in which MRI is the sole imaging modality used for treatment planning and dose calculations. To enable such a workflow, synthetic CT (sCT) data must be generated based on a patient’s MRI data so that dose calculations may be performed using the electron density information derived from CT images. In this study, we propose a novel deep spatial pyramid convolutional framework for the MRI‐to‐CT image‐to‐image translation task and compare its performance to the well established U‐Net architecture in a generative adversarial network (GAN) framework. Methods Our proposed framework utilizes atrous convolution in a method named atrous spatial pyramid pooling (ASPP) to significantly reduce the total number of parameters required to describe the model while effectively capturing rich, multi‐scale structural information in a manner that is not possible in the conventional framework. The proposed framework consists of a generative model composed of stacked encoders and decoders separated by the ASPP module, where atrous convolution is applied at increasing rates in parallel to encode large‐scale features. The performance of the proposed method is compared to that of the conventional GAN framework in terms of the time required to train the model and the image quality of the generated sCT as measured by the root mean square error (RMSE), structural similarity index (SSIM), and peak signal‐to‐noise ratio (PSNR) depending on the size of the training data set. Dose calculations based on sCT data generated using the proposed architecture are also compared to clinical plans to evaluate the dosimetric accuracy of the method. Results Significant reductions in training time and improvements in image quality are observed at every training data set size when the proposed framework is adopted instead of the conventional framework. Over 1042 test images, values of 17.7 ± 4.3 HU, 0.9995 ± 0.0003, and 71.7 ± 2.3 are observed for the RMSE, SSIM, and PSNR metrics, respectively. Dose distributions calculated based on sCT data generated using the proposed framework demonstrate passing ra
doi_str_mv 10.1002/mp.13716
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2258732269</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2258732269</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3216-4d31fb7fae2001ca3fb565c9af89a2fc134af9c6d6bafc712060edc91dd6fe453</originalsourceid><addsrcrecordid>eNp1kM1KxDAURoMoOo6CTyBZuul4k7TpdCmDf-Cg6LguaX402jY1aZXufASf0Sex44y6cnXh43AuHIQOCEwIAD2umglhKeEbaETjlEUxhWwTjQCyOKIxJDtoN4QnAOAsgW20wwiDLJnyEfJ3fd0-6tZKPFtgr6WrQ-s72VpX4y7Y-gELrLRucGhEa0WJm96Lyio8kK-u7JbgsJph1G_OP2PjPJ7ffr5_uLrsceG1CC32Qlk3_PGi6ffQlhFl0PvrO0b3Z6eL2UV0dX1-OTu5iiSjhEexYsQUqRGaAhApmCkSnshMmGkmqJGExcJkkiteCCNTQoGDVjIjSnGj44SN0dHK23j30unQ5pUNUpelqLXrQk5pMk0ZpTz7Q6V3IXht8sbbSvg-J5AvC-dVk38XHtDDtbUrKq1-wZ-kAxCtgDdb6v5fUT6_WQm_AG0EiEo</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2258732269</pqid></control><display><type>article</type><title>Synthetic CT reconstruction using a deep spatial pyramid convolutional framework for MR‐only breast radiotherapy</title><source>Wiley</source><creator>Olberg, Sven ; Zhang, Hao ; Kennedy, William R. ; Chun, Jaehee ; Rodriguez, Vivian ; Zoberi, Imran ; Thomas, Maria A. ; Kim, Jin Sung ; Mutic, Sasa ; Green, Olga L. ; Park, Justin C.</creator><creatorcontrib>Olberg, Sven ; Zhang, Hao ; Kennedy, William R. ; Chun, Jaehee ; Rodriguez, Vivian ; Zoberi, Imran ; Thomas, Maria A. ; Kim, Jin Sung ; Mutic, Sasa ; Green, Olga L. ; Park, Justin C.</creatorcontrib><description>Purpose The superior soft‐tissue contrast achieved using magnetic resonance imaging (MRI) compared to x‐ray computed tomography (CT) has led to the popularization of MRI‐guided radiation therapy (MR‐IGRT), especially in recent years with the advent of first and second generation MRI‐based therapy delivery systems for MR‐IGRT. The expanding use of these systems is driving interest in MRI‐only RT workflows in which MRI is the sole imaging modality used for treatment planning and dose calculations. To enable such a workflow, synthetic CT (sCT) data must be generated based on a patient’s MRI data so that dose calculations may be performed using the electron density information derived from CT images. In this study, we propose a novel deep spatial pyramid convolutional framework for the MRI‐to‐CT image‐to‐image translation task and compare its performance to the well established U‐Net architecture in a generative adversarial network (GAN) framework. Methods Our proposed framework utilizes atrous convolution in a method named atrous spatial pyramid pooling (ASPP) to significantly reduce the total number of parameters required to describe the model while effectively capturing rich, multi‐scale structural information in a manner that is not possible in the conventional framework. The proposed framework consists of a generative model composed of stacked encoders and decoders separated by the ASPP module, where atrous convolution is applied at increasing rates in parallel to encode large‐scale features. The performance of the proposed method is compared to that of the conventional GAN framework in terms of the time required to train the model and the image quality of the generated sCT as measured by the root mean square error (RMSE), structural similarity index (SSIM), and peak signal‐to‐noise ratio (PSNR) depending on the size of the training data set. Dose calculations based on sCT data generated using the proposed architecture are also compared to clinical plans to evaluate the dosimetric accuracy of the method. Results Significant reductions in training time and improvements in image quality are observed at every training data set size when the proposed framework is adopted instead of the conventional framework. Over 1042 test images, values of 17.7 ± 4.3 HU, 0.9995 ± 0.0003, and 71.7 ± 2.3 are observed for the RMSE, SSIM, and PSNR metrics, respectively. Dose distributions calculated based on sCT data generated using the proposed framework demonstrate passing rates equal to or greater than 98% using the 3D gamma index with a 2%/2 mm criterion. Conclusions The deep spatial pyramid convolutional framework proposed here demonstrates improved performance compared to the conventional GAN framework that has been applied to the image‐to‐image translation task of sCT generation. Adopting the method is a first step toward an MRI‐only RT workflow that enables widespread clinical applications for MR‐IGRT including online adaptive therapy.</description><identifier>ISSN: 0094-2405</identifier><identifier>EISSN: 2473-4209</identifier><identifier>DOI: 10.1002/mp.13716</identifier><identifier>PMID: 31309586</identifier><language>eng</language><publisher>United States</publisher><subject>Breast Neoplasms - diagnostic imaging ; Breast Neoplasms - radiotherapy ; Deep Learning ; Humans ; Image Processing, Computer-Assisted - methods ; machine learning ; Magnetic Resonance Imaging ; MRI ; MRI‐guided RT ; MRI‐only RT ; Radiotherapy Dosage ; Radiotherapy Planning, Computer-Assisted ; Radiotherapy, Image-Guided ; synthetic CT ; Tomography, X-Ray Computed</subject><ispartof>Medical physics (Lancaster), 2019-09, Vol.46 (9), p.4135-4147</ispartof><rights>2019 American Association of Physicists in Medicine</rights><rights>2019 American Association of Physicists in Medicine.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3216-4d31fb7fae2001ca3fb565c9af89a2fc134af9c6d6bafc712060edc91dd6fe453</citedby><cites>FETCH-LOGICAL-c3216-4d31fb7fae2001ca3fb565c9af89a2fc134af9c6d6bafc712060edc91dd6fe453</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31309586$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Olberg, Sven</creatorcontrib><creatorcontrib>Zhang, Hao</creatorcontrib><creatorcontrib>Kennedy, William R.</creatorcontrib><creatorcontrib>Chun, Jaehee</creatorcontrib><creatorcontrib>Rodriguez, Vivian</creatorcontrib><creatorcontrib>Zoberi, Imran</creatorcontrib><creatorcontrib>Thomas, Maria A.</creatorcontrib><creatorcontrib>Kim, Jin Sung</creatorcontrib><creatorcontrib>Mutic, Sasa</creatorcontrib><creatorcontrib>Green, Olga L.</creatorcontrib><creatorcontrib>Park, Justin C.</creatorcontrib><title>Synthetic CT reconstruction using a deep spatial pyramid convolutional framework for MR‐only breast radiotherapy</title><title>Medical physics (Lancaster)</title><addtitle>Med Phys</addtitle><description>Purpose The superior soft‐tissue contrast achieved using magnetic resonance imaging (MRI) compared to x‐ray computed tomography (CT) has led to the popularization of MRI‐guided radiation therapy (MR‐IGRT), especially in recent years with the advent of first and second generation MRI‐based therapy delivery systems for MR‐IGRT. The expanding use of these systems is driving interest in MRI‐only RT workflows in which MRI is the sole imaging modality used for treatment planning and dose calculations. To enable such a workflow, synthetic CT (sCT) data must be generated based on a patient’s MRI data so that dose calculations may be performed using the electron density information derived from CT images. In this study, we propose a novel deep spatial pyramid convolutional framework for the MRI‐to‐CT image‐to‐image translation task and compare its performance to the well established U‐Net architecture in a generative adversarial network (GAN) framework. Methods Our proposed framework utilizes atrous convolution in a method named atrous spatial pyramid pooling (ASPP) to significantly reduce the total number of parameters required to describe the model while effectively capturing rich, multi‐scale structural information in a manner that is not possible in the conventional framework. The proposed framework consists of a generative model composed of stacked encoders and decoders separated by the ASPP module, where atrous convolution is applied at increasing rates in parallel to encode large‐scale features. The performance of the proposed method is compared to that of the conventional GAN framework in terms of the time required to train the model and the image quality of the generated sCT as measured by the root mean square error (RMSE), structural similarity index (SSIM), and peak signal‐to‐noise ratio (PSNR) depending on the size of the training data set. Dose calculations based on sCT data generated using the proposed architecture are also compared to clinical plans to evaluate the dosimetric accuracy of the method. Results Significant reductions in training time and improvements in image quality are observed at every training data set size when the proposed framework is adopted instead of the conventional framework. Over 1042 test images, values of 17.7 ± 4.3 HU, 0.9995 ± 0.0003, and 71.7 ± 2.3 are observed for the RMSE, SSIM, and PSNR metrics, respectively. Dose distributions calculated based on sCT data generated using the proposed framework demonstrate passing rates equal to or greater than 98% using the 3D gamma index with a 2%/2 mm criterion. Conclusions The deep spatial pyramid convolutional framework proposed here demonstrates improved performance compared to the conventional GAN framework that has been applied to the image‐to‐image translation task of sCT generation. Adopting the method is a first step toward an MRI‐only RT workflow that enables widespread clinical applications for MR‐IGRT including online adaptive therapy.</description><subject>Breast Neoplasms - diagnostic imaging</subject><subject>Breast Neoplasms - radiotherapy</subject><subject>Deep Learning</subject><subject>Humans</subject><subject>Image Processing, Computer-Assisted - methods</subject><subject>machine learning</subject><subject>Magnetic Resonance Imaging</subject><subject>MRI</subject><subject>MRI‐guided RT</subject><subject>MRI‐only RT</subject><subject>Radiotherapy Dosage</subject><subject>Radiotherapy Planning, Computer-Assisted</subject><subject>Radiotherapy, Image-Guided</subject><subject>synthetic CT</subject><subject>Tomography, X-Ray Computed</subject><issn>0094-2405</issn><issn>2473-4209</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp1kM1KxDAURoMoOo6CTyBZuul4k7TpdCmDf-Cg6LguaX402jY1aZXufASf0Sex44y6cnXh43AuHIQOCEwIAD2umglhKeEbaETjlEUxhWwTjQCyOKIxJDtoN4QnAOAsgW20wwiDLJnyEfJ3fd0-6tZKPFtgr6WrQ-s72VpX4y7Y-gELrLRucGhEa0WJm96Lyio8kK-u7JbgsJph1G_OP2PjPJ7ffr5_uLrsceG1CC32Qlk3_PGi6ffQlhFl0PvrO0b3Z6eL2UV0dX1-OTu5iiSjhEexYsQUqRGaAhApmCkSnshMmGkmqJGExcJkkiteCCNTQoGDVjIjSnGj44SN0dHK23j30unQ5pUNUpelqLXrQk5pMk0ZpTz7Q6V3IXht8sbbSvg-J5AvC-dVk38XHtDDtbUrKq1-wZ-kAxCtgDdb6v5fUT6_WQm_AG0EiEo</recordid><startdate>201909</startdate><enddate>201909</enddate><creator>Olberg, Sven</creator><creator>Zhang, Hao</creator><creator>Kennedy, William R.</creator><creator>Chun, Jaehee</creator><creator>Rodriguez, Vivian</creator><creator>Zoberi, Imran</creator><creator>Thomas, Maria A.</creator><creator>Kim, Jin Sung</creator><creator>Mutic, Sasa</creator><creator>Green, Olga L.</creator><creator>Park, Justin C.</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201909</creationdate><title>Synthetic CT reconstruction using a deep spatial pyramid convolutional framework for MR‐only breast radiotherapy</title><author>Olberg, Sven ; Zhang, Hao ; Kennedy, William R. ; Chun, Jaehee ; Rodriguez, Vivian ; Zoberi, Imran ; Thomas, Maria A. ; Kim, Jin Sung ; Mutic, Sasa ; Green, Olga L. ; Park, Justin C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3216-4d31fb7fae2001ca3fb565c9af89a2fc134af9c6d6bafc712060edc91dd6fe453</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Breast Neoplasms - diagnostic imaging</topic><topic>Breast Neoplasms - radiotherapy</topic><topic>Deep Learning</topic><topic>Humans</topic><topic>Image Processing, Computer-Assisted - methods</topic><topic>machine learning</topic><topic>Magnetic Resonance Imaging</topic><topic>MRI</topic><topic>MRI‐guided RT</topic><topic>MRI‐only RT</topic><topic>Radiotherapy Dosage</topic><topic>Radiotherapy Planning, Computer-Assisted</topic><topic>Radiotherapy, Image-Guided</topic><topic>synthetic CT</topic><topic>Tomography, X-Ray Computed</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Olberg, Sven</creatorcontrib><creatorcontrib>Zhang, Hao</creatorcontrib><creatorcontrib>Kennedy, William R.</creatorcontrib><creatorcontrib>Chun, Jaehee</creatorcontrib><creatorcontrib>Rodriguez, Vivian</creatorcontrib><creatorcontrib>Zoberi, Imran</creatorcontrib><creatorcontrib>Thomas, Maria A.</creatorcontrib><creatorcontrib>Kim, Jin Sung</creatorcontrib><creatorcontrib>Mutic, Sasa</creatorcontrib><creatorcontrib>Green, Olga L.</creatorcontrib><creatorcontrib>Park, Justin C.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Medical physics (Lancaster)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Olberg, Sven</au><au>Zhang, Hao</au><au>Kennedy, William R.</au><au>Chun, Jaehee</au><au>Rodriguez, Vivian</au><au>Zoberi, Imran</au><au>Thomas, Maria A.</au><au>Kim, Jin Sung</au><au>Mutic, Sasa</au><au>Green, Olga L.</au><au>Park, Justin C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Synthetic CT reconstruction using a deep spatial pyramid convolutional framework for MR‐only breast radiotherapy</atitle><jtitle>Medical physics (Lancaster)</jtitle><addtitle>Med Phys</addtitle><date>2019-09</date><risdate>2019</risdate><volume>46</volume><issue>9</issue><spage>4135</spage><epage>4147</epage><pages>4135-4147</pages><issn>0094-2405</issn><eissn>2473-4209</eissn><abstract>Purpose The superior soft‐tissue contrast achieved using magnetic resonance imaging (MRI) compared to x‐ray computed tomography (CT) has led to the popularization of MRI‐guided radiation therapy (MR‐IGRT), especially in recent years with the advent of first and second generation MRI‐based therapy delivery systems for MR‐IGRT. The expanding use of these systems is driving interest in MRI‐only RT workflows in which MRI is the sole imaging modality used for treatment planning and dose calculations. To enable such a workflow, synthetic CT (sCT) data must be generated based on a patient’s MRI data so that dose calculations may be performed using the electron density information derived from CT images. In this study, we propose a novel deep spatial pyramid convolutional framework for the MRI‐to‐CT image‐to‐image translation task and compare its performance to the well established U‐Net architecture in a generative adversarial network (GAN) framework. Methods Our proposed framework utilizes atrous convolution in a method named atrous spatial pyramid pooling (ASPP) to significantly reduce the total number of parameters required to describe the model while effectively capturing rich, multi‐scale structural information in a manner that is not possible in the conventional framework. The proposed framework consists of a generative model composed of stacked encoders and decoders separated by the ASPP module, where atrous convolution is applied at increasing rates in parallel to encode large‐scale features. The performance of the proposed method is compared to that of the conventional GAN framework in terms of the time required to train the model and the image quality of the generated sCT as measured by the root mean square error (RMSE), structural similarity index (SSIM), and peak signal‐to‐noise ratio (PSNR) depending on the size of the training data set. Dose calculations based on sCT data generated using the proposed architecture are also compared to clinical plans to evaluate the dosimetric accuracy of the method. Results Significant reductions in training time and improvements in image quality are observed at every training data set size when the proposed framework is adopted instead of the conventional framework. Over 1042 test images, values of 17.7 ± 4.3 HU, 0.9995 ± 0.0003, and 71.7 ± 2.3 are observed for the RMSE, SSIM, and PSNR metrics, respectively. Dose distributions calculated based on sCT data generated using the proposed framework demonstrate passing rates equal to or greater than 98% using the 3D gamma index with a 2%/2 mm criterion. Conclusions The deep spatial pyramid convolutional framework proposed here demonstrates improved performance compared to the conventional GAN framework that has been applied to the image‐to‐image translation task of sCT generation. Adopting the method is a first step toward an MRI‐only RT workflow that enables widespread clinical applications for MR‐IGRT including online adaptive therapy.</abstract><cop>United States</cop><pmid>31309586</pmid><doi>10.1002/mp.13716</doi><tpages>13</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0094-2405
ispartof Medical physics (Lancaster), 2019-09, Vol.46 (9), p.4135-4147
issn 0094-2405
2473-4209
language eng
recordid cdi_proquest_miscellaneous_2258732269
source Wiley
subjects Breast Neoplasms - diagnostic imaging
Breast Neoplasms - radiotherapy
Deep Learning
Humans
Image Processing, Computer-Assisted - methods
machine learning
Magnetic Resonance Imaging
MRI
MRI‐guided RT
MRI‐only RT
Radiotherapy Dosage
Radiotherapy Planning, Computer-Assisted
Radiotherapy, Image-Guided
synthetic CT
Tomography, X-Ray Computed
title Synthetic CT reconstruction using a deep spatial pyramid convolutional framework for MR‐only breast radiotherapy
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-29T16%3A46%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Synthetic%20CT%20reconstruction%20using%20a%20deep%20spatial%20pyramid%20convolutional%20framework%20for%20MR%E2%80%90only%20breast%20radiotherapy&rft.jtitle=Medical%20physics%20(Lancaster)&rft.au=Olberg,%20Sven&rft.date=2019-09&rft.volume=46&rft.issue=9&rft.spage=4135&rft.epage=4147&rft.pages=4135-4147&rft.issn=0094-2405&rft.eissn=2473-4209&rft_id=info:doi/10.1002/mp.13716&rft_dat=%3Cproquest_cross%3E2258732269%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3216-4d31fb7fae2001ca3fb565c9af89a2fc134af9c6d6bafc712060edc91dd6fe453%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2258732269&rft_id=info:pmid/31309586&rfr_iscdi=true