"Real-Time" Diagnostics for a Laser Fusion System

An automated diagnostic system has been developed and installed on a multibeam laser for fusion research. Laser-beam phase and intensity profile, focal-spot profile, pulse width, beam energy, and other laser parameters are measured at a number of points in the system. Data from the optical and volta...

Full description

Saved in:
Bibliographic Details
Published in:Optical Engineering 1976-02, Vol.15 (1), p.150129-150129
Main Authors: Applebaum, D. C, Grieser, D. R, Beal, J. W, Epstein, H. M, Mallozzi, P. J
Format: Article
Language:English
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:An automated diagnostic system has been developed and installed on a multibeam laser for fusion research. Laser-beam phase and intensity profile, focal-spot profile, pulse width, beam energy, and other laser parameters are measured at a number of points in the system. Data from the optical and voltage sensing elements are processed by an on-line mini-computer and the information is presented in graphic, pictorial, and tabular form. The processed information is used
ISSN:0091-3286
1560-2303