Loading…

Sensitivity and binding kinetics of an ultra-sensitive chemiluminescent enzyme-linked immunosorbent assay at arrays of antibodies

We have characterized the sensitivity and kinetics of a multiplex immunoassay system based on detection of chemiluminescence (CL) at arrays of antibodies. This enzyme-linked immunosorbent assay (ELISA) was based on the spotting of different antibodies in a circular pattern at the bottom of a well of...

Full description

Saved in:
Bibliographic Details
Published in:Journal of immunological methods 2019-11, Vol.474, p.112643-112643, Article 112643
Main Authors: Tobos, Carmen I., Kim, Seunghyeon, Rissin, David M., Johnson, Joseph M., Douglas, Scott, Yan, Susan, Nie, Shuai, Rice, Bradley, Sung, Ki-Joo, Sikes, Hadley D., Duffy, David C.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c353t-5cb645cad0f4b58006eca7803fe2a4c57238763473137ea97f59c80e8caa8bc23
cites cdi_FETCH-LOGICAL-c353t-5cb645cad0f4b58006eca7803fe2a4c57238763473137ea97f59c80e8caa8bc23
container_end_page 112643
container_issue
container_start_page 112643
container_title Journal of immunological methods
container_volume 474
creator Tobos, Carmen I.
Kim, Seunghyeon
Rissin, David M.
Johnson, Joseph M.
Douglas, Scott
Yan, Susan
Nie, Shuai
Rice, Bradley
Sung, Ki-Joo
Sikes, Hadley D.
Duffy, David C.
description We have characterized the sensitivity and kinetics of a multiplex immunoassay system based on detection of chemiluminescence (CL) at arrays of antibodies. This enzyme-linked immunosorbent assay (ELISA) was based on the spotting of different antibodies in a circular pattern at the bottom of a well of a microtiter plate. Sandwich immunocomplexes within each spot were labeled with horse radish peroxidase, and CL was generated locally to each spot in the array from turnover of luminol substrate. CL from the arrays across the plate was collected in single images; long exposure times were used to maximize sensitivity, and short exposure times were used to extend the dynamic range at higher signals. Image analysis was used to determine the intensity of light from each spot in the array, and intensity was converted to concentration of protein via comparison to a calibration curve. To determine the intrinsic sensitivity of the CL ELISA array, streptavidin horseradish peroxidase (SA-HRP) was captured on an array spotted with biotinylated detection antibodies. The limit of detection (LOD) of SA-HRP was 105 aM, or 3200 enzymes per 50 μL. A single-plex assay for prostate specific antigen (PSA) was developed that had an LOD of 79 aM when the microtiter plate was shaken orbitally, comparable to the most sensitive immunoassays reported to date. Normalization of CL signals in the PSA assay to signal per molecule of SA-HRP showed that the efficiency of the shaken assay was ~40%. When the plates were not shaken, the efficiency was ~4.5%, i.e., ~9-fold lower than when shaken. To better understand the theoretical basis of the sensitivity of these assays, we developed COMSOL numerical models of the binding kinetics at the array for plates that were shaken orbitally and those not shaken. Experimental data from the orbitally shaken PSA assay were best modeled by inertial mixing in a three-layer system that included a 8-μm-thick concentration boundary layer. Experimental data from the unshaken PSA assay were well modeled by diffusion-limited kinetics. A single-plex assay for IL-10 was developed with an LOD of 69 aM or 1.5 fg/mL, and used to measure this cytokine in plasma and serum of 10 healthy individuals. A 5-plex assay for IL-5, IL-6, IL-10, IL-22, and TNF-α was developed with LODs of 56 aM, 237 aM, 69 aM, 88 aM, and 373 aM, respectively. The assay was used to measure these 5 cytokines in the plasma and serum of the same individuals. The correlation in concentration of IL-10 m
doi_str_mv 10.1016/j.jim.2019.112643
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2272222765</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0022175919302431</els_id><sourcerecordid>2272222765</sourcerecordid><originalsourceid>FETCH-LOGICAL-c353t-5cb645cad0f4b58006eca7803fe2a4c57238763473137ea97f59c80e8caa8bc23</originalsourceid><addsrcrecordid>eNp9kMFu1DAQhi0EotvCA3BBOXLJMrbjOBEnVBWoVKmHtmfLcSYw29gptlNpufHmeLULR3zxyPPNJ8_P2DsOWw68_bjb7shvBfB-y7loG_mCbXinRa17UC_ZBkCImmvVn7HzlHYAwKGF1-xM8uZQ6g37fYchUaZnyvvKhrEaKIwUvlePFDCTS9UylfdqnXO0dTrBWLkf6GlefaGSw5ArDL_2HuuZwiOOFXm_hiUtcTj0bEq22EsRo92flJmGZSRMb9iryc4J357uC_bw5er-8lt9c_v1-vLzTe2kkrlWbmgb5ewIUzOoDqBFZ3UHckJhG6e0kJ1uZaMllxptryfVuw6wc9Z2gxPygn04ep_i8nPFlI2n8vV5tgGXNRkhtChHt6qg_Ii6uKQUcTJPkbyNe8PBHJI3O1OSN4fkzTH5MvP-pF8Hj-O_ib9RF-DTEcCy5DNhNMkRBocjRXTZjAv9R_8HB1CW3w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2272222765</pqid></control><display><type>article</type><title>Sensitivity and binding kinetics of an ultra-sensitive chemiluminescent enzyme-linked immunosorbent assay at arrays of antibodies</title><source>ScienceDirect Freedom Collection</source><creator>Tobos, Carmen I. ; Kim, Seunghyeon ; Rissin, David M. ; Johnson, Joseph M. ; Douglas, Scott ; Yan, Susan ; Nie, Shuai ; Rice, Bradley ; Sung, Ki-Joo ; Sikes, Hadley D. ; Duffy, David C.</creator><creatorcontrib>Tobos, Carmen I. ; Kim, Seunghyeon ; Rissin, David M. ; Johnson, Joseph M. ; Douglas, Scott ; Yan, Susan ; Nie, Shuai ; Rice, Bradley ; Sung, Ki-Joo ; Sikes, Hadley D. ; Duffy, David C.</creatorcontrib><description>We have characterized the sensitivity and kinetics of a multiplex immunoassay system based on detection of chemiluminescence (CL) at arrays of antibodies. This enzyme-linked immunosorbent assay (ELISA) was based on the spotting of different antibodies in a circular pattern at the bottom of a well of a microtiter plate. Sandwich immunocomplexes within each spot were labeled with horse radish peroxidase, and CL was generated locally to each spot in the array from turnover of luminol substrate. CL from the arrays across the plate was collected in single images; long exposure times were used to maximize sensitivity, and short exposure times were used to extend the dynamic range at higher signals. Image analysis was used to determine the intensity of light from each spot in the array, and intensity was converted to concentration of protein via comparison to a calibration curve. To determine the intrinsic sensitivity of the CL ELISA array, streptavidin horseradish peroxidase (SA-HRP) was captured on an array spotted with biotinylated detection antibodies. The limit of detection (LOD) of SA-HRP was 105 aM, or 3200 enzymes per 50 μL. A single-plex assay for prostate specific antigen (PSA) was developed that had an LOD of 79 aM when the microtiter plate was shaken orbitally, comparable to the most sensitive immunoassays reported to date. Normalization of CL signals in the PSA assay to signal per molecule of SA-HRP showed that the efficiency of the shaken assay was ~40%. When the plates were not shaken, the efficiency was ~4.5%, i.e., ~9-fold lower than when shaken. To better understand the theoretical basis of the sensitivity of these assays, we developed COMSOL numerical models of the binding kinetics at the array for plates that were shaken orbitally and those not shaken. Experimental data from the orbitally shaken PSA assay were best modeled by inertial mixing in a three-layer system that included a 8-μm-thick concentration boundary layer. Experimental data from the unshaken PSA assay were well modeled by diffusion-limited kinetics. A single-plex assay for IL-10 was developed with an LOD of 69 aM or 1.5 fg/mL, and used to measure this cytokine in plasma and serum of 10 healthy individuals. A 5-plex assay for IL-5, IL-6, IL-10, IL-22, and TNF-α was developed with LODs of 56 aM, 237 aM, 69 aM, 88 aM, and 373 aM, respectively. The assay was used to measure these 5 cytokines in the plasma and serum of the same individuals. The correlation in concentration of IL-10 measured in single-plex and multiplex assays was good (r2 = 0.89; bias = 14.5%). The factors that result in the high sensitivity of CL ELISA arrays—mostly high signal to noise ratio of extended chemiluminescent imaging—are discussed. This multiplex CL ELISA could be used for sensitive profiling of multiple proteins for in vitro diagnostics and biomarker detection in the development of therapeutics. •Characterization of a multiplex immunoassay system based on detection of chemiluminescence at arrays of capture antibodies.•Highly sensitive assays for PSA, IL-10, and a 5-plex of IL-5, IL-6, IL-10, IL-22, and TNF-α are reported.•Theoretical models are presented that describe the kinetics of immunocomplex formation at the array in shaken ELISA plates.</description><identifier>ISSN: 0022-1759</identifier><identifier>EISSN: 1872-7905</identifier><identifier>DOI: 10.1016/j.jim.2019.112643</identifier><identifier>PMID: 31401067</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Antibodies - immunology ; Antibodies - metabolism ; Antibody Specificity ; Antigen-Antibody Reactions ; Biomarkers - blood ; Cytokines - blood ; Cytokines - immunology ; Diffusion ; Enzyme-Linked Immunosorbent Assay ; Healthy Volunteers ; Humans ; Interleukin-10 - blood ; Interleukin-10 - immunology ; Interleukin-22 ; Interleukin-5 - blood ; Interleukin-5 - immunology ; Interleukin-6 - blood ; Interleukin-6 - immunology ; Interleukins - blood ; Interleukins - immunology ; Kinetics ; Limit of Detection ; Luminescent Measurements ; Predictive Value of Tests ; Protein Binding ; Reproducibility of Results ; Tumor Necrosis Factor-alpha - blood ; Tumor Necrosis Factor-alpha - immunology</subject><ispartof>Journal of immunological methods, 2019-11, Vol.474, p.112643-112643, Article 112643</ispartof><rights>2019 Elsevier B.V.</rights><rights>Copyright © 2019 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c353t-5cb645cad0f4b58006eca7803fe2a4c57238763473137ea97f59c80e8caa8bc23</citedby><cites>FETCH-LOGICAL-c353t-5cb645cad0f4b58006eca7803fe2a4c57238763473137ea97f59c80e8caa8bc23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31401067$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Tobos, Carmen I.</creatorcontrib><creatorcontrib>Kim, Seunghyeon</creatorcontrib><creatorcontrib>Rissin, David M.</creatorcontrib><creatorcontrib>Johnson, Joseph M.</creatorcontrib><creatorcontrib>Douglas, Scott</creatorcontrib><creatorcontrib>Yan, Susan</creatorcontrib><creatorcontrib>Nie, Shuai</creatorcontrib><creatorcontrib>Rice, Bradley</creatorcontrib><creatorcontrib>Sung, Ki-Joo</creatorcontrib><creatorcontrib>Sikes, Hadley D.</creatorcontrib><creatorcontrib>Duffy, David C.</creatorcontrib><title>Sensitivity and binding kinetics of an ultra-sensitive chemiluminescent enzyme-linked immunosorbent assay at arrays of antibodies</title><title>Journal of immunological methods</title><addtitle>J Immunol Methods</addtitle><description>We have characterized the sensitivity and kinetics of a multiplex immunoassay system based on detection of chemiluminescence (CL) at arrays of antibodies. This enzyme-linked immunosorbent assay (ELISA) was based on the spotting of different antibodies in a circular pattern at the bottom of a well of a microtiter plate. Sandwich immunocomplexes within each spot were labeled with horse radish peroxidase, and CL was generated locally to each spot in the array from turnover of luminol substrate. CL from the arrays across the plate was collected in single images; long exposure times were used to maximize sensitivity, and short exposure times were used to extend the dynamic range at higher signals. Image analysis was used to determine the intensity of light from each spot in the array, and intensity was converted to concentration of protein via comparison to a calibration curve. To determine the intrinsic sensitivity of the CL ELISA array, streptavidin horseradish peroxidase (SA-HRP) was captured on an array spotted with biotinylated detection antibodies. The limit of detection (LOD) of SA-HRP was 105 aM, or 3200 enzymes per 50 μL. A single-plex assay for prostate specific antigen (PSA) was developed that had an LOD of 79 aM when the microtiter plate was shaken orbitally, comparable to the most sensitive immunoassays reported to date. Normalization of CL signals in the PSA assay to signal per molecule of SA-HRP showed that the efficiency of the shaken assay was ~40%. When the plates were not shaken, the efficiency was ~4.5%, i.e., ~9-fold lower than when shaken. To better understand the theoretical basis of the sensitivity of these assays, we developed COMSOL numerical models of the binding kinetics at the array for plates that were shaken orbitally and those not shaken. Experimental data from the orbitally shaken PSA assay were best modeled by inertial mixing in a three-layer system that included a 8-μm-thick concentration boundary layer. Experimental data from the unshaken PSA assay were well modeled by diffusion-limited kinetics. A single-plex assay for IL-10 was developed with an LOD of 69 aM or 1.5 fg/mL, and used to measure this cytokine in plasma and serum of 10 healthy individuals. A 5-plex assay for IL-5, IL-6, IL-10, IL-22, and TNF-α was developed with LODs of 56 aM, 237 aM, 69 aM, 88 aM, and 373 aM, respectively. The assay was used to measure these 5 cytokines in the plasma and serum of the same individuals. The correlation in concentration of IL-10 measured in single-plex and multiplex assays was good (r2 = 0.89; bias = 14.5%). The factors that result in the high sensitivity of CL ELISA arrays—mostly high signal to noise ratio of extended chemiluminescent imaging—are discussed. This multiplex CL ELISA could be used for sensitive profiling of multiple proteins for in vitro diagnostics and biomarker detection in the development of therapeutics. •Characterization of a multiplex immunoassay system based on detection of chemiluminescence at arrays of capture antibodies.•Highly sensitive assays for PSA, IL-10, and a 5-plex of IL-5, IL-6, IL-10, IL-22, and TNF-α are reported.•Theoretical models are presented that describe the kinetics of immunocomplex formation at the array in shaken ELISA plates.</description><subject>Antibodies - immunology</subject><subject>Antibodies - metabolism</subject><subject>Antibody Specificity</subject><subject>Antigen-Antibody Reactions</subject><subject>Biomarkers - blood</subject><subject>Cytokines - blood</subject><subject>Cytokines - immunology</subject><subject>Diffusion</subject><subject>Enzyme-Linked Immunosorbent Assay</subject><subject>Healthy Volunteers</subject><subject>Humans</subject><subject>Interleukin-10 - blood</subject><subject>Interleukin-10 - immunology</subject><subject>Interleukin-22</subject><subject>Interleukin-5 - blood</subject><subject>Interleukin-5 - immunology</subject><subject>Interleukin-6 - blood</subject><subject>Interleukin-6 - immunology</subject><subject>Interleukins - blood</subject><subject>Interleukins - immunology</subject><subject>Kinetics</subject><subject>Limit of Detection</subject><subject>Luminescent Measurements</subject><subject>Predictive Value of Tests</subject><subject>Protein Binding</subject><subject>Reproducibility of Results</subject><subject>Tumor Necrosis Factor-alpha - blood</subject><subject>Tumor Necrosis Factor-alpha - immunology</subject><issn>0022-1759</issn><issn>1872-7905</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp9kMFu1DAQhi0EotvCA3BBOXLJMrbjOBEnVBWoVKmHtmfLcSYw29gptlNpufHmeLULR3zxyPPNJ8_P2DsOWw68_bjb7shvBfB-y7loG_mCbXinRa17UC_ZBkCImmvVn7HzlHYAwKGF1-xM8uZQ6g37fYchUaZnyvvKhrEaKIwUvlePFDCTS9UylfdqnXO0dTrBWLkf6GlefaGSw5ArDL_2HuuZwiOOFXm_hiUtcTj0bEq22EsRo92flJmGZSRMb9iryc4J357uC_bw5er-8lt9c_v1-vLzTe2kkrlWbmgb5ewIUzOoDqBFZ3UHckJhG6e0kJ1uZaMllxptryfVuw6wc9Z2gxPygn04ep_i8nPFlI2n8vV5tgGXNRkhtChHt6qg_Ii6uKQUcTJPkbyNe8PBHJI3O1OSN4fkzTH5MvP-pF8Hj-O_ib9RF-DTEcCy5DNhNMkRBocjRXTZjAv9R_8HB1CW3w</recordid><startdate>201911</startdate><enddate>201911</enddate><creator>Tobos, Carmen I.</creator><creator>Kim, Seunghyeon</creator><creator>Rissin, David M.</creator><creator>Johnson, Joseph M.</creator><creator>Douglas, Scott</creator><creator>Yan, Susan</creator><creator>Nie, Shuai</creator><creator>Rice, Bradley</creator><creator>Sung, Ki-Joo</creator><creator>Sikes, Hadley D.</creator><creator>Duffy, David C.</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201911</creationdate><title>Sensitivity and binding kinetics of an ultra-sensitive chemiluminescent enzyme-linked immunosorbent assay at arrays of antibodies</title><author>Tobos, Carmen I. ; Kim, Seunghyeon ; Rissin, David M. ; Johnson, Joseph M. ; Douglas, Scott ; Yan, Susan ; Nie, Shuai ; Rice, Bradley ; Sung, Ki-Joo ; Sikes, Hadley D. ; Duffy, David C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c353t-5cb645cad0f4b58006eca7803fe2a4c57238763473137ea97f59c80e8caa8bc23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Antibodies - immunology</topic><topic>Antibodies - metabolism</topic><topic>Antibody Specificity</topic><topic>Antigen-Antibody Reactions</topic><topic>Biomarkers - blood</topic><topic>Cytokines - blood</topic><topic>Cytokines - immunology</topic><topic>Diffusion</topic><topic>Enzyme-Linked Immunosorbent Assay</topic><topic>Healthy Volunteers</topic><topic>Humans</topic><topic>Interleukin-10 - blood</topic><topic>Interleukin-10 - immunology</topic><topic>Interleukin-22</topic><topic>Interleukin-5 - blood</topic><topic>Interleukin-5 - immunology</topic><topic>Interleukin-6 - blood</topic><topic>Interleukin-6 - immunology</topic><topic>Interleukins - blood</topic><topic>Interleukins - immunology</topic><topic>Kinetics</topic><topic>Limit of Detection</topic><topic>Luminescent Measurements</topic><topic>Predictive Value of Tests</topic><topic>Protein Binding</topic><topic>Reproducibility of Results</topic><topic>Tumor Necrosis Factor-alpha - blood</topic><topic>Tumor Necrosis Factor-alpha - immunology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tobos, Carmen I.</creatorcontrib><creatorcontrib>Kim, Seunghyeon</creatorcontrib><creatorcontrib>Rissin, David M.</creatorcontrib><creatorcontrib>Johnson, Joseph M.</creatorcontrib><creatorcontrib>Douglas, Scott</creatorcontrib><creatorcontrib>Yan, Susan</creatorcontrib><creatorcontrib>Nie, Shuai</creatorcontrib><creatorcontrib>Rice, Bradley</creatorcontrib><creatorcontrib>Sung, Ki-Joo</creatorcontrib><creatorcontrib>Sikes, Hadley D.</creatorcontrib><creatorcontrib>Duffy, David C.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of immunological methods</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tobos, Carmen I.</au><au>Kim, Seunghyeon</au><au>Rissin, David M.</au><au>Johnson, Joseph M.</au><au>Douglas, Scott</au><au>Yan, Susan</au><au>Nie, Shuai</au><au>Rice, Bradley</au><au>Sung, Ki-Joo</au><au>Sikes, Hadley D.</au><au>Duffy, David C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sensitivity and binding kinetics of an ultra-sensitive chemiluminescent enzyme-linked immunosorbent assay at arrays of antibodies</atitle><jtitle>Journal of immunological methods</jtitle><addtitle>J Immunol Methods</addtitle><date>2019-11</date><risdate>2019</risdate><volume>474</volume><spage>112643</spage><epage>112643</epage><pages>112643-112643</pages><artnum>112643</artnum><issn>0022-1759</issn><eissn>1872-7905</eissn><abstract>We have characterized the sensitivity and kinetics of a multiplex immunoassay system based on detection of chemiluminescence (CL) at arrays of antibodies. This enzyme-linked immunosorbent assay (ELISA) was based on the spotting of different antibodies in a circular pattern at the bottom of a well of a microtiter plate. Sandwich immunocomplexes within each spot were labeled with horse radish peroxidase, and CL was generated locally to each spot in the array from turnover of luminol substrate. CL from the arrays across the plate was collected in single images; long exposure times were used to maximize sensitivity, and short exposure times were used to extend the dynamic range at higher signals. Image analysis was used to determine the intensity of light from each spot in the array, and intensity was converted to concentration of protein via comparison to a calibration curve. To determine the intrinsic sensitivity of the CL ELISA array, streptavidin horseradish peroxidase (SA-HRP) was captured on an array spotted with biotinylated detection antibodies. The limit of detection (LOD) of SA-HRP was 105 aM, or 3200 enzymes per 50 μL. A single-plex assay for prostate specific antigen (PSA) was developed that had an LOD of 79 aM when the microtiter plate was shaken orbitally, comparable to the most sensitive immunoassays reported to date. Normalization of CL signals in the PSA assay to signal per molecule of SA-HRP showed that the efficiency of the shaken assay was ~40%. When the plates were not shaken, the efficiency was ~4.5%, i.e., ~9-fold lower than when shaken. To better understand the theoretical basis of the sensitivity of these assays, we developed COMSOL numerical models of the binding kinetics at the array for plates that were shaken orbitally and those not shaken. Experimental data from the orbitally shaken PSA assay were best modeled by inertial mixing in a three-layer system that included a 8-μm-thick concentration boundary layer. Experimental data from the unshaken PSA assay were well modeled by diffusion-limited kinetics. A single-plex assay for IL-10 was developed with an LOD of 69 aM or 1.5 fg/mL, and used to measure this cytokine in plasma and serum of 10 healthy individuals. A 5-plex assay for IL-5, IL-6, IL-10, IL-22, and TNF-α was developed with LODs of 56 aM, 237 aM, 69 aM, 88 aM, and 373 aM, respectively. The assay was used to measure these 5 cytokines in the plasma and serum of the same individuals. The correlation in concentration of IL-10 measured in single-plex and multiplex assays was good (r2 = 0.89; bias = 14.5%). The factors that result in the high sensitivity of CL ELISA arrays—mostly high signal to noise ratio of extended chemiluminescent imaging—are discussed. This multiplex CL ELISA could be used for sensitive profiling of multiple proteins for in vitro diagnostics and biomarker detection in the development of therapeutics. •Characterization of a multiplex immunoassay system based on detection of chemiluminescence at arrays of capture antibodies.•Highly sensitive assays for PSA, IL-10, and a 5-plex of IL-5, IL-6, IL-10, IL-22, and TNF-α are reported.•Theoretical models are presented that describe the kinetics of immunocomplex formation at the array in shaken ELISA plates.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>31401067</pmid><doi>10.1016/j.jim.2019.112643</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0022-1759
ispartof Journal of immunological methods, 2019-11, Vol.474, p.112643-112643, Article 112643
issn 0022-1759
1872-7905
language eng
recordid cdi_proquest_miscellaneous_2272222765
source ScienceDirect Freedom Collection
subjects Antibodies - immunology
Antibodies - metabolism
Antibody Specificity
Antigen-Antibody Reactions
Biomarkers - blood
Cytokines - blood
Cytokines - immunology
Diffusion
Enzyme-Linked Immunosorbent Assay
Healthy Volunteers
Humans
Interleukin-10 - blood
Interleukin-10 - immunology
Interleukin-22
Interleukin-5 - blood
Interleukin-5 - immunology
Interleukin-6 - blood
Interleukin-6 - immunology
Interleukins - blood
Interleukins - immunology
Kinetics
Limit of Detection
Luminescent Measurements
Predictive Value of Tests
Protein Binding
Reproducibility of Results
Tumor Necrosis Factor-alpha - blood
Tumor Necrosis Factor-alpha - immunology
title Sensitivity and binding kinetics of an ultra-sensitive chemiluminescent enzyme-linked immunosorbent assay at arrays of antibodies
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T22%3A56%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sensitivity%20and%20binding%20kinetics%20of%20an%20ultra-sensitive%20chemiluminescent%20enzyme-linked%20immunosorbent%20assay%20at%20arrays%20of%20antibodies&rft.jtitle=Journal%20of%20immunological%20methods&rft.au=Tobos,%20Carmen%20I.&rft.date=2019-11&rft.volume=474&rft.spage=112643&rft.epage=112643&rft.pages=112643-112643&rft.artnum=112643&rft.issn=0022-1759&rft.eissn=1872-7905&rft_id=info:doi/10.1016/j.jim.2019.112643&rft_dat=%3Cproquest_cross%3E2272222765%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c353t-5cb645cad0f4b58006eca7803fe2a4c57238763473137ea97f59c80e8caa8bc23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2272222765&rft_id=info:pmid/31401067&rfr_iscdi=true