Rigor and Reproducibility of Cytometry Practices for Immuno‐Oncology: A multifaceted challenge

The rapid advancement of immunotherapy strategies has created a need for technologies that can reliably and reproducibly identify rare populations, detect subtle changes in modulatory signals, and assess antigenic expression patterns that are time‐sensitive. Accomplishing these tasks requires carefu...

Full description

Saved in:
Bibliographic Details
Published in:Cytometry. Part A 2020-02, Vol.97 (2), p.116-125
Main Authors: Laskowski, Tamara J., Hazen, Amy L., Collazo, Renata S., Haviland, David
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c4022-35aa342a8b79728450460c774fa05e88921c61221ddf4c465a62123c27e6f9b93
cites cdi_FETCH-LOGICAL-c4022-35aa342a8b79728450460c774fa05e88921c61221ddf4c465a62123c27e6f9b93
container_end_page 125
container_issue 2
container_start_page 116
container_title Cytometry. Part A
container_volume 97
creator Laskowski, Tamara J.
Hazen, Amy L.
Collazo, Renata S.
Haviland, David
description The rapid advancement of immunotherapy strategies has created a need for technologies that can reliably and reproducibly identify rare populations, detect subtle changes in modulatory signals, and assess antigenic expression patterns that are time‐sensitive. Accomplishing these tasks requires careful planning and the employment of tools that provide greater sensitivity and specificity without demanding extensive time. Flow Cytometry has earned its place as a preferred analysis platform. This technology offers a flexible path to the interrogation of protein expression patterns and detection of functional properties in cell populations of interest. Mass Cytometry is a newcomer technology that has generated significant interest in the field. By incorporating mass spectrometry analysis to the traditional principles of flow cytometry, this innovative tool promises to significantly expand the ability to detect multiple proteins on a single cell. The use of these technologies in a manner that is consistent and reproducible through multiple sample sets demands careful attention to experiment design, reagent selection, and instrumentation. Whether applying flow or mass cytometry, reaching successful, reliable results involves many factors. Sample preparation, antibody titrations, and appropriate controls are major biological considerations that impact cytometric analysis. Additionally, instrument voltages, lasers, and run quality assessments are essential for ensuring comparability and reproducibility between analyses. In this article, we aim to discuss the critical aspects that impact flow cytometry, and will touch on important considerations for mass cytometry as well. Focusing on their relevance to immunotherapy studies, we will address the importance of appropriate sample processing and will discuss how selection of suitable panels, controls, and antibodies must follow a carefully designed plan. We will also comment on how educated use of instrumentation plays a significant role in the reliability and reproducibility of results.Through this work, we hope to contribute to the effort toward establishing higher standards for rigor and reproducibility of cytometry practices by researchers, operators, and general cytometry users employing cytometry‐based assays in their work. © 2019 International Society for Advancement of Cytometry
doi_str_mv 10.1002/cyto.a.23882
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2281116210</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2281116210</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4022-35aa342a8b79728450460c774fa05e88921c61221ddf4c465a62123c27e6f9b93</originalsourceid><addsrcrecordid>eNp9kD1PGzEYgC0EAkq7dUaWWBia1H5t3wdbFEEbCSlVlA6dXMfnSx35zsG-E7qNn9DfyC_BaQJDBya_w_M-ev0g9JmSMSUEvuqh82M1BlYUcITOqRAw4iUjx28zwBn6EOOGECYIg1N0xigXnAp2jn4v7NoHrNoKL8w2-KrXdmWd7QbsazxN7sZ0YcA_gtKd1SbiOuGzpulb__z0d95q7_x6uMET3PSus7XSpjMV1n-Uc6Zdm4_opFYumk-H9wL9vLtdTr-P7uffZtPJ_UhzAjBiQinGQRWrvMyh4ILwjOg857UiwhRFCVRnFIBWVc01z4TKgALTkJusLlclu0DXe2_6xENvYicbG7VxTrXG91ECFJTStEQSevUfuvF9aNN1EhjPQGSCFIn6sqd08DEGU8ttsI0Kg6RE7srLXXmp5L_yCb88SPtVY6o3-DV1AvgeeLTODO_K5PTXcj7Ze18Af1uPmg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2346256508</pqid></control><display><type>article</type><title>Rigor and Reproducibility of Cytometry Practices for Immuno‐Oncology: A multifaceted challenge</title><source>Wiley-Blackwell Read &amp; Publish Collection</source><creator>Laskowski, Tamara J. ; Hazen, Amy L. ; Collazo, Renata S. ; Haviland, David</creator><creatorcontrib>Laskowski, Tamara J. ; Hazen, Amy L. ; Collazo, Renata S. ; Haviland, David</creatorcontrib><description>The rapid advancement of immunotherapy strategies has created a need for technologies that can reliably and reproducibly identify rare populations, detect subtle changes in modulatory signals, and assess antigenic expression patterns that are time‐sensitive. Accomplishing these tasks requires careful planning and the employment of tools that provide greater sensitivity and specificity without demanding extensive time. Flow Cytometry has earned its place as a preferred analysis platform. This technology offers a flexible path to the interrogation of protein expression patterns and detection of functional properties in cell populations of interest. Mass Cytometry is a newcomer technology that has generated significant interest in the field. By incorporating mass spectrometry analysis to the traditional principles of flow cytometry, this innovative tool promises to significantly expand the ability to detect multiple proteins on a single cell. The use of these technologies in a manner that is consistent and reproducible through multiple sample sets demands careful attention to experiment design, reagent selection, and instrumentation. Whether applying flow or mass cytometry, reaching successful, reliable results involves many factors. Sample preparation, antibody titrations, and appropriate controls are major biological considerations that impact cytometric analysis. Additionally, instrument voltages, lasers, and run quality assessments are essential for ensuring comparability and reproducibility between analyses. In this article, we aim to discuss the critical aspects that impact flow cytometry, and will touch on important considerations for mass cytometry as well. Focusing on their relevance to immunotherapy studies, we will address the importance of appropriate sample processing and will discuss how selection of suitable panels, controls, and antibodies must follow a carefully designed plan. We will also comment on how educated use of instrumentation plays a significant role in the reliability and reproducibility of results.Through this work, we hope to contribute to the effort toward establishing higher standards for rigor and reproducibility of cytometry practices by researchers, operators, and general cytometry users employing cytometry‐based assays in their work. © 2019 International Society for Advancement of Cytometry</description><identifier>ISSN: 1552-4922</identifier><identifier>EISSN: 1552-4930</identifier><identifier>DOI: 10.1002/cyto.a.23882</identifier><identifier>PMID: 31454153</identifier><language>eng</language><publisher>Hoboken, USA: John Wiley &amp; Sons, Inc</publisher><subject>Antibodies ; Antigens ; Cancer immunotherapy ; Change detection ; Control equipment ; Design of experiments ; Flow cytometry ; Immunotherapy ; Impact analysis ; Instrumentation ; Instruments ; Interrogation ; Lasers ; Mass spectrometry ; Mass spectroscopy ; Medical research ; Oncology ; Populations ; Proteins ; Quality assessment ; Reagents ; Reproducibility ; Sample preparation ; Technology assessment</subject><ispartof>Cytometry. Part A, 2020-02, Vol.97 (2), p.116-125</ispartof><rights>2019 International Society for Advancement of Cytometry</rights><rights>2019 International Society for Advancement of Cytometry.</rights><rights>2020 International Society for Advancement of Cytometry</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4022-35aa342a8b79728450460c774fa05e88921c61221ddf4c465a62123c27e6f9b93</citedby><cites>FETCH-LOGICAL-c4022-35aa342a8b79728450460c774fa05e88921c61221ddf4c465a62123c27e6f9b93</cites><orcidid>0000-0002-8444-1983</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31454153$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Laskowski, Tamara J.</creatorcontrib><creatorcontrib>Hazen, Amy L.</creatorcontrib><creatorcontrib>Collazo, Renata S.</creatorcontrib><creatorcontrib>Haviland, David</creatorcontrib><title>Rigor and Reproducibility of Cytometry Practices for Immuno‐Oncology: A multifaceted challenge</title><title>Cytometry. Part A</title><addtitle>Cytometry A</addtitle><description>The rapid advancement of immunotherapy strategies has created a need for technologies that can reliably and reproducibly identify rare populations, detect subtle changes in modulatory signals, and assess antigenic expression patterns that are time‐sensitive. Accomplishing these tasks requires careful planning and the employment of tools that provide greater sensitivity and specificity without demanding extensive time. Flow Cytometry has earned its place as a preferred analysis platform. This technology offers a flexible path to the interrogation of protein expression patterns and detection of functional properties in cell populations of interest. Mass Cytometry is a newcomer technology that has generated significant interest in the field. By incorporating mass spectrometry analysis to the traditional principles of flow cytometry, this innovative tool promises to significantly expand the ability to detect multiple proteins on a single cell. The use of these technologies in a manner that is consistent and reproducible through multiple sample sets demands careful attention to experiment design, reagent selection, and instrumentation. Whether applying flow or mass cytometry, reaching successful, reliable results involves many factors. Sample preparation, antibody titrations, and appropriate controls are major biological considerations that impact cytometric analysis. Additionally, instrument voltages, lasers, and run quality assessments are essential for ensuring comparability and reproducibility between analyses. In this article, we aim to discuss the critical aspects that impact flow cytometry, and will touch on important considerations for mass cytometry as well. Focusing on their relevance to immunotherapy studies, we will address the importance of appropriate sample processing and will discuss how selection of suitable panels, controls, and antibodies must follow a carefully designed plan. We will also comment on how educated use of instrumentation plays a significant role in the reliability and reproducibility of results.Through this work, we hope to contribute to the effort toward establishing higher standards for rigor and reproducibility of cytometry practices by researchers, operators, and general cytometry users employing cytometry‐based assays in their work. © 2019 International Society for Advancement of Cytometry</description><subject>Antibodies</subject><subject>Antigens</subject><subject>Cancer immunotherapy</subject><subject>Change detection</subject><subject>Control equipment</subject><subject>Design of experiments</subject><subject>Flow cytometry</subject><subject>Immunotherapy</subject><subject>Impact analysis</subject><subject>Instrumentation</subject><subject>Instruments</subject><subject>Interrogation</subject><subject>Lasers</subject><subject>Mass spectrometry</subject><subject>Mass spectroscopy</subject><subject>Medical research</subject><subject>Oncology</subject><subject>Populations</subject><subject>Proteins</subject><subject>Quality assessment</subject><subject>Reagents</subject><subject>Reproducibility</subject><subject>Sample preparation</subject><subject>Technology assessment</subject><issn>1552-4922</issn><issn>1552-4930</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9kD1PGzEYgC0EAkq7dUaWWBia1H5t3wdbFEEbCSlVlA6dXMfnSx35zsG-E7qNn9DfyC_BaQJDBya_w_M-ev0g9JmSMSUEvuqh82M1BlYUcITOqRAw4iUjx28zwBn6EOOGECYIg1N0xigXnAp2jn4v7NoHrNoKL8w2-KrXdmWd7QbsazxN7sZ0YcA_gtKd1SbiOuGzpulb__z0d95q7_x6uMET3PSus7XSpjMV1n-Uc6Zdm4_opFYumk-H9wL9vLtdTr-P7uffZtPJ_UhzAjBiQinGQRWrvMyh4ILwjOg857UiwhRFCVRnFIBWVc01z4TKgALTkJusLlclu0DXe2_6xENvYicbG7VxTrXG91ECFJTStEQSevUfuvF9aNN1EhjPQGSCFIn6sqd08DEGU8ttsI0Kg6RE7srLXXmp5L_yCb88SPtVY6o3-DV1AvgeeLTODO_K5PTXcj7Ze18Af1uPmg</recordid><startdate>202002</startdate><enddate>202002</enddate><creator>Laskowski, Tamara J.</creator><creator>Hazen, Amy L.</creator><creator>Collazo, Renata S.</creator><creator>Haviland, David</creator><general>John Wiley &amp; Sons, Inc</general><general>Wiley Subscription Services, Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>7TK</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-8444-1983</orcidid></search><sort><creationdate>202002</creationdate><title>Rigor and Reproducibility of Cytometry Practices for Immuno‐Oncology: A multifaceted challenge</title><author>Laskowski, Tamara J. ; Hazen, Amy L. ; Collazo, Renata S. ; Haviland, David</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4022-35aa342a8b79728450460c774fa05e88921c61221ddf4c465a62123c27e6f9b93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Antibodies</topic><topic>Antigens</topic><topic>Cancer immunotherapy</topic><topic>Change detection</topic><topic>Control equipment</topic><topic>Design of experiments</topic><topic>Flow cytometry</topic><topic>Immunotherapy</topic><topic>Impact analysis</topic><topic>Instrumentation</topic><topic>Instruments</topic><topic>Interrogation</topic><topic>Lasers</topic><topic>Mass spectrometry</topic><topic>Mass spectroscopy</topic><topic>Medical research</topic><topic>Oncology</topic><topic>Populations</topic><topic>Proteins</topic><topic>Quality assessment</topic><topic>Reagents</topic><topic>Reproducibility</topic><topic>Sample preparation</topic><topic>Technology assessment</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Laskowski, Tamara J.</creatorcontrib><creatorcontrib>Hazen, Amy L.</creatorcontrib><creatorcontrib>Collazo, Renata S.</creatorcontrib><creatorcontrib>Haviland, David</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Neurosciences Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Cytometry. Part A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Laskowski, Tamara J.</au><au>Hazen, Amy L.</au><au>Collazo, Renata S.</au><au>Haviland, David</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Rigor and Reproducibility of Cytometry Practices for Immuno‐Oncology: A multifaceted challenge</atitle><jtitle>Cytometry. Part A</jtitle><addtitle>Cytometry A</addtitle><date>2020-02</date><risdate>2020</risdate><volume>97</volume><issue>2</issue><spage>116</spage><epage>125</epage><pages>116-125</pages><issn>1552-4922</issn><eissn>1552-4930</eissn><abstract>The rapid advancement of immunotherapy strategies has created a need for technologies that can reliably and reproducibly identify rare populations, detect subtle changes in modulatory signals, and assess antigenic expression patterns that are time‐sensitive. Accomplishing these tasks requires careful planning and the employment of tools that provide greater sensitivity and specificity without demanding extensive time. Flow Cytometry has earned its place as a preferred analysis platform. This technology offers a flexible path to the interrogation of protein expression patterns and detection of functional properties in cell populations of interest. Mass Cytometry is a newcomer technology that has generated significant interest in the field. By incorporating mass spectrometry analysis to the traditional principles of flow cytometry, this innovative tool promises to significantly expand the ability to detect multiple proteins on a single cell. The use of these technologies in a manner that is consistent and reproducible through multiple sample sets demands careful attention to experiment design, reagent selection, and instrumentation. Whether applying flow or mass cytometry, reaching successful, reliable results involves many factors. Sample preparation, antibody titrations, and appropriate controls are major biological considerations that impact cytometric analysis. Additionally, instrument voltages, lasers, and run quality assessments are essential for ensuring comparability and reproducibility between analyses. In this article, we aim to discuss the critical aspects that impact flow cytometry, and will touch on important considerations for mass cytometry as well. Focusing on their relevance to immunotherapy studies, we will address the importance of appropriate sample processing and will discuss how selection of suitable panels, controls, and antibodies must follow a carefully designed plan. We will also comment on how educated use of instrumentation plays a significant role in the reliability and reproducibility of results.Through this work, we hope to contribute to the effort toward establishing higher standards for rigor and reproducibility of cytometry practices by researchers, operators, and general cytometry users employing cytometry‐based assays in their work. © 2019 International Society for Advancement of Cytometry</abstract><cop>Hoboken, USA</cop><pub>John Wiley &amp; Sons, Inc</pub><pmid>31454153</pmid><doi>10.1002/cyto.a.23882</doi><tpages>10</tpages><orcidid>https://orcid.org/0000-0002-8444-1983</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1552-4922
ispartof Cytometry. Part A, 2020-02, Vol.97 (2), p.116-125
issn 1552-4922
1552-4930
language eng
recordid cdi_proquest_miscellaneous_2281116210
source Wiley-Blackwell Read & Publish Collection
subjects Antibodies
Antigens
Cancer immunotherapy
Change detection
Control equipment
Design of experiments
Flow cytometry
Immunotherapy
Impact analysis
Instrumentation
Instruments
Interrogation
Lasers
Mass spectrometry
Mass spectroscopy
Medical research
Oncology
Populations
Proteins
Quality assessment
Reagents
Reproducibility
Sample preparation
Technology assessment
title Rigor and Reproducibility of Cytometry Practices for Immuno‐Oncology: A multifaceted challenge
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T08%3A59%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Rigor%20and%20Reproducibility%20of%20Cytometry%20Practices%20for%20Immuno%E2%80%90Oncology:%20A%20multifaceted%20challenge&rft.jtitle=Cytometry.%20Part%20A&rft.au=Laskowski,%20Tamara%20J.&rft.date=2020-02&rft.volume=97&rft.issue=2&rft.spage=116&rft.epage=125&rft.pages=116-125&rft.issn=1552-4922&rft.eissn=1552-4930&rft_id=info:doi/10.1002/cyto.a.23882&rft_dat=%3Cproquest_cross%3E2281116210%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c4022-35aa342a8b79728450460c774fa05e88921c61221ddf4c465a62123c27e6f9b93%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2346256508&rft_id=info:pmid/31454153&rfr_iscdi=true