Loading…

Time-Resolved Freely Dissolved Concentrations of Semivolatile and Hydrophobic Test Chemicals in In Vitro AssaysMeasuring High Losses and Crossover by Headspace Solid-Phase Microextraction

In vitro assays are normally conducted in plastic multiwell plates open to exchange with the ambient air. The concentration of test substances freely available to cells is often not known, can change over time, and is difficult to measure in the small volumes in microplates. However, even a well-cha...

Full description

Saved in:
Bibliographic Details
Published in:Chemical research in toxicology 2019-09, Vol.32 (9), p.1780-1790
Main Authors: Birch, Heidi, Kramer, Nynke I, Mayer, Philipp
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In vitro assays are normally conducted in plastic multiwell plates open to exchange with the ambient air. The concentration of test substances freely available to cells is often not known, can change over time, and is difficult to measure in the small volumes in microplates. However, even a well-characterized toxicological response is of limited value if it cannot be linked to a well-defined exposure level. The aim of this study was to develop and apply an approach for determining time-resolved freely dissolved concentrations of semivolatile and hydrophobic organic chemicals (SVHOCs) in in vitro assays: (1) free fractions were measured by a new medium dilution method and (2) time-resolved loss curves were obtained by measurements of total concentrations in 96-well plates during incubations at 37 °C. Headspace solid-phase microextraction was used as an analytical technique for 24 model chemicals spanning 6 chemical groups and 4–5 orders of magnitude in K ow and K aw. Free fractions were >30% for chemicals with log K ow < 3.5 and then decreased with increasing log K ow. Medium concentrations declined significantly (>50%) within 24 h of incubation for all 20 chemicals having log K ow > 4 or log K aw > −3.5 in serum-free medium. Losses of chemicals were lower for medium containing 10% fetal bovine serum, most significantly for chemicals with log K ow > 4. High crossover to neighboring wells also was observed below log K ow of 4 and log K aw of −3.5. Sealing the well plates had limited effect on the losses but clearly reduced crossover. The high losses and crossover of most tested chemicals question the suitability of multiwell plates for in vitro testing of SVHOCs and call for (1) test systems that minimize losses, (2) methods to control in vitro exposure, (3) analytical confirmation of exposure, and (4) exposure control and confirmation being included in good in vitro reporting standards.
ISSN:0893-228X
1520-5010
DOI:10.1021/acs.chemrestox.9b00133