Loading…

A high-profile thread with grit-blasted and acid-etched surface reduces loosening of medial column fusion bolt in instable Charcot foot

•Bony consolidation of fusion sites is improved using surface modified medial column fusion bolt in Charcot foot.•Despite an initial restoration of the foot arch in both groups loss of correction was seen in controls only.•Frequency of adverse events like bolt dislocation and bolt breakage was reduc...

Full description

Saved in:
Bibliographic Details
Published in:Foot and ankle surgery 2020-08, Vol.26 (6), p.637-643
Main Authors: Mehlhorn, Alexander T., Ugland, Karl I., Hörterer, Hubert, Gottschalk, Oliver, Südkamp, Norbert, Walther, Markus
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c353t-605912d4f252c0165369e518af6ec9b9fc89e263fadc0ea3092d53ab1d8d5dc43
cites cdi_FETCH-LOGICAL-c353t-605912d4f252c0165369e518af6ec9b9fc89e263fadc0ea3092d53ab1d8d5dc43
container_end_page 643
container_issue 6
container_start_page 637
container_title Foot and ankle surgery
container_volume 26
creator Mehlhorn, Alexander T.
Ugland, Karl I.
Hörterer, Hubert
Gottschalk, Oliver
Südkamp, Norbert
Walther, Markus
description •Bony consolidation of fusion sites is improved using surface modified medial column fusion bolt in Charcot foot.•Despite an initial restoration of the foot arch in both groups loss of correction was seen in controls only.•Frequency of adverse events like bolt dislocation and bolt breakage was reduced. Intramedullary fusion bolts (FB) were introduced to stabilize the medial column of the instable Charcot foot (ICF), but complications as bolt loosening or breakage are frequent. We compared the use of a standard FB and a high-profile threaded FB with a grit-blasted surface. We hypothesized that implant related complications occurred less often and osseous consolidation of fusion sites was more distinctive using the latter type of FB. Consecutive patients suffering from an ICF were stabilized with a high-profile threaded and surface-modified FB (HTFB) (n=20) or with a standard FB (n=20) which was placed into the first ray. Additional bolts and dorsal low-profile plates were applied in every patient. In a retrospective assessment osseous consolidation of the fusion sites was analyzed at 3 month and quantified by CT scan. At 3 and 12 month longitudinal foot arch collapse and rate of bolt loosening were assessed. Compared to the control group, the HTFB group reached significant higher consolidation after 3 month. No dislocation and a single bolt breakage was observed in the HTFB group after the fourth month, while the control group included 3 patients with bolt dislocation at 3±1 month and 5 patients with bolt breakage at 6±1.8 month. Compared to preoperative values, the improvement of Meary’s angle after one-year was significant higher in the HTFB group (23.4°±14) than in controls (11.7°±13). Modification of bolt design improves the stability of the medial column: A higher rate of osseous consolidation of the medial column leads to lower rate of bolt dislocation/breakage and finally to permanently erected longitudinal foot arch. Initially disappointing results following medial column stabilization with fusion bolts can be rejected by modifications of bolt design and its technical application.
doi_str_mv 10.1016/j.fas.2019.08.004
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2290975910</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1268773119301365</els_id><sourcerecordid>2290975910</sourcerecordid><originalsourceid>FETCH-LOGICAL-c353t-605912d4f252c0165369e518af6ec9b9fc89e263fadc0ea3092d53ab1d8d5dc43</originalsourceid><addsrcrecordid>eNp9kM-KFDEQxoMo7h99AC-So5duK0mnp4OnZVhdYcGLnkM6qUxnyHTWJK34BL62WWb1KFRRVfDVV9SPkDcMegZsfH_svSk9B6Z6mHqA4Rm5ZMMInZLT8Lz1fJy63U6wC3JVyhEAdgrES3IhmORMMnVJft_QJRyW7iEnHyLSumQ0jv4MdaGHHGo3R1MqOmrWlja4Dqtd2ly27I1FmtFtFguNKRVcw3qgydMTumAitSlup5X6rYS00jnFSsPaolQzt1v7xWSbKvUp1VfkhTex4Ounek2-fbz9ur_r7r98-ry_ue-skKJ2I0jFuBs8l9w2BFKMCiWbjB_Rqll5Oynko_DGWUAjQHEnhZmZm5x0dhDX5N3Ztz38fcNS9SkUizGaFdNWNOcK1K4dgSZlZ6nNqZSMXj_kcDL5l2agH_nro2789SN_DZNu_NvO2yf7bW4Q_m38Bd4EH84CbE_-CJh1sQFX24BltFW7FP5j_weMOJfB</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2290975910</pqid></control><display><type>article</type><title>A high-profile thread with grit-blasted and acid-etched surface reduces loosening of medial column fusion bolt in instable Charcot foot</title><source>Elsevier</source><creator>Mehlhorn, Alexander T. ; Ugland, Karl I. ; Hörterer, Hubert ; Gottschalk, Oliver ; Südkamp, Norbert ; Walther, Markus</creator><creatorcontrib>Mehlhorn, Alexander T. ; Ugland, Karl I. ; Hörterer, Hubert ; Gottschalk, Oliver ; Südkamp, Norbert ; Walther, Markus</creatorcontrib><description>•Bony consolidation of fusion sites is improved using surface modified medial column fusion bolt in Charcot foot.•Despite an initial restoration of the foot arch in both groups loss of correction was seen in controls only.•Frequency of adverse events like bolt dislocation and bolt breakage was reduced. Intramedullary fusion bolts (FB) were introduced to stabilize the medial column of the instable Charcot foot (ICF), but complications as bolt loosening or breakage are frequent. We compared the use of a standard FB and a high-profile threaded FB with a grit-blasted surface. We hypothesized that implant related complications occurred less often and osseous consolidation of fusion sites was more distinctive using the latter type of FB. Consecutive patients suffering from an ICF were stabilized with a high-profile threaded and surface-modified FB (HTFB) (n=20) or with a standard FB (n=20) which was placed into the first ray. Additional bolts and dorsal low-profile plates were applied in every patient. In a retrospective assessment osseous consolidation of the fusion sites was analyzed at 3 month and quantified by CT scan. At 3 and 12 month longitudinal foot arch collapse and rate of bolt loosening were assessed. Compared to the control group, the HTFB group reached significant higher consolidation after 3 month. No dislocation and a single bolt breakage was observed in the HTFB group after the fourth month, while the control group included 3 patients with bolt dislocation at 3±1 month and 5 patients with bolt breakage at 6±1.8 month. Compared to preoperative values, the improvement of Meary’s angle after one-year was significant higher in the HTFB group (23.4°±14) than in controls (11.7°±13). Modification of bolt design improves the stability of the medial column: A higher rate of osseous consolidation of the medial column leads to lower rate of bolt dislocation/breakage and finally to permanently erected longitudinal foot arch. Initially disappointing results following medial column stabilization with fusion bolts can be rejected by modifications of bolt design and its technical application.</description><identifier>ISSN: 1268-7731</identifier><identifier>EISSN: 1460-9584</identifier><identifier>DOI: 10.1016/j.fas.2019.08.004</identifier><identifier>PMID: 31521519</identifier><language>eng</language><publisher>France: Elsevier Ltd</publisher><subject>Arthrodesis - instrumentation ; Arthropathy, Neurogenic - diagnostic imaging ; Arthropathy, Neurogenic - surgery ; Bone Nails ; Case-Control Studies ; Charcot foot ; Diabetes mellitus ; Female ; Foot Bones - diagnostic imaging ; Foot Bones - surgery ; Foot Joints - diagnostic imaging ; Foot Joints - surgery ; Fusion bolt ; Humans ; Male ; Middle Aged ; Osseointegration ; Surface Properties ; Tomography, X-Ray Computed</subject><ispartof>Foot and ankle surgery, 2020-08, Vol.26 (6), p.637-643</ispartof><rights>2019 European Foot and Ankle Society</rights><rights>Copyright © 2019 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c353t-605912d4f252c0165369e518af6ec9b9fc89e263fadc0ea3092d53ab1d8d5dc43</citedby><cites>FETCH-LOGICAL-c353t-605912d4f252c0165369e518af6ec9b9fc89e263fadc0ea3092d53ab1d8d5dc43</cites><orcidid>0000-0003-1122-1303</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31521519$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mehlhorn, Alexander T.</creatorcontrib><creatorcontrib>Ugland, Karl I.</creatorcontrib><creatorcontrib>Hörterer, Hubert</creatorcontrib><creatorcontrib>Gottschalk, Oliver</creatorcontrib><creatorcontrib>Südkamp, Norbert</creatorcontrib><creatorcontrib>Walther, Markus</creatorcontrib><title>A high-profile thread with grit-blasted and acid-etched surface reduces loosening of medial column fusion bolt in instable Charcot foot</title><title>Foot and ankle surgery</title><addtitle>Foot Ankle Surg</addtitle><description>•Bony consolidation of fusion sites is improved using surface modified medial column fusion bolt in Charcot foot.•Despite an initial restoration of the foot arch in both groups loss of correction was seen in controls only.•Frequency of adverse events like bolt dislocation and bolt breakage was reduced. Intramedullary fusion bolts (FB) were introduced to stabilize the medial column of the instable Charcot foot (ICF), but complications as bolt loosening or breakage are frequent. We compared the use of a standard FB and a high-profile threaded FB with a grit-blasted surface. We hypothesized that implant related complications occurred less often and osseous consolidation of fusion sites was more distinctive using the latter type of FB. Consecutive patients suffering from an ICF were stabilized with a high-profile threaded and surface-modified FB (HTFB) (n=20) or with a standard FB (n=20) which was placed into the first ray. Additional bolts and dorsal low-profile plates were applied in every patient. In a retrospective assessment osseous consolidation of the fusion sites was analyzed at 3 month and quantified by CT scan. At 3 and 12 month longitudinal foot arch collapse and rate of bolt loosening were assessed. Compared to the control group, the HTFB group reached significant higher consolidation after 3 month. No dislocation and a single bolt breakage was observed in the HTFB group after the fourth month, while the control group included 3 patients with bolt dislocation at 3±1 month and 5 patients with bolt breakage at 6±1.8 month. Compared to preoperative values, the improvement of Meary’s angle after one-year was significant higher in the HTFB group (23.4°±14) than in controls (11.7°±13). Modification of bolt design improves the stability of the medial column: A higher rate of osseous consolidation of the medial column leads to lower rate of bolt dislocation/breakage and finally to permanently erected longitudinal foot arch. Initially disappointing results following medial column stabilization with fusion bolts can be rejected by modifications of bolt design and its technical application.</description><subject>Arthrodesis - instrumentation</subject><subject>Arthropathy, Neurogenic - diagnostic imaging</subject><subject>Arthropathy, Neurogenic - surgery</subject><subject>Bone Nails</subject><subject>Case-Control Studies</subject><subject>Charcot foot</subject><subject>Diabetes mellitus</subject><subject>Female</subject><subject>Foot Bones - diagnostic imaging</subject><subject>Foot Bones - surgery</subject><subject>Foot Joints - diagnostic imaging</subject><subject>Foot Joints - surgery</subject><subject>Fusion bolt</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Osseointegration</subject><subject>Surface Properties</subject><subject>Tomography, X-Ray Computed</subject><issn>1268-7731</issn><issn>1460-9584</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9kM-KFDEQxoMo7h99AC-So5duK0mnp4OnZVhdYcGLnkM6qUxnyHTWJK34BL62WWb1KFRRVfDVV9SPkDcMegZsfH_svSk9B6Z6mHqA4Rm5ZMMInZLT8Lz1fJy63U6wC3JVyhEAdgrES3IhmORMMnVJft_QJRyW7iEnHyLSumQ0jv4MdaGHHGo3R1MqOmrWlja4Dqtd2ly27I1FmtFtFguNKRVcw3qgydMTumAitSlup5X6rYS00jnFSsPaolQzt1v7xWSbKvUp1VfkhTex4Ounek2-fbz9ur_r7r98-ry_ue-skKJ2I0jFuBs8l9w2BFKMCiWbjB_Rqll5Oynko_DGWUAjQHEnhZmZm5x0dhDX5N3Ztz38fcNS9SkUizGaFdNWNOcK1K4dgSZlZ6nNqZSMXj_kcDL5l2agH_nro2789SN_DZNu_NvO2yf7bW4Q_m38Bd4EH84CbE_-CJh1sQFX24BltFW7FP5j_weMOJfB</recordid><startdate>202008</startdate><enddate>202008</enddate><creator>Mehlhorn, Alexander T.</creator><creator>Ugland, Karl I.</creator><creator>Hörterer, Hubert</creator><creator>Gottschalk, Oliver</creator><creator>Südkamp, Norbert</creator><creator>Walther, Markus</creator><general>Elsevier Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-1122-1303</orcidid></search><sort><creationdate>202008</creationdate><title>A high-profile thread with grit-blasted and acid-etched surface reduces loosening of medial column fusion bolt in instable Charcot foot</title><author>Mehlhorn, Alexander T. ; Ugland, Karl I. ; Hörterer, Hubert ; Gottschalk, Oliver ; Südkamp, Norbert ; Walther, Markus</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c353t-605912d4f252c0165369e518af6ec9b9fc89e263fadc0ea3092d53ab1d8d5dc43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Arthrodesis - instrumentation</topic><topic>Arthropathy, Neurogenic - diagnostic imaging</topic><topic>Arthropathy, Neurogenic - surgery</topic><topic>Bone Nails</topic><topic>Case-Control Studies</topic><topic>Charcot foot</topic><topic>Diabetes mellitus</topic><topic>Female</topic><topic>Foot Bones - diagnostic imaging</topic><topic>Foot Bones - surgery</topic><topic>Foot Joints - diagnostic imaging</topic><topic>Foot Joints - surgery</topic><topic>Fusion bolt</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Osseointegration</topic><topic>Surface Properties</topic><topic>Tomography, X-Ray Computed</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mehlhorn, Alexander T.</creatorcontrib><creatorcontrib>Ugland, Karl I.</creatorcontrib><creatorcontrib>Hörterer, Hubert</creatorcontrib><creatorcontrib>Gottschalk, Oliver</creatorcontrib><creatorcontrib>Südkamp, Norbert</creatorcontrib><creatorcontrib>Walther, Markus</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Foot and ankle surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mehlhorn, Alexander T.</au><au>Ugland, Karl I.</au><au>Hörterer, Hubert</au><au>Gottschalk, Oliver</au><au>Südkamp, Norbert</au><au>Walther, Markus</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A high-profile thread with grit-blasted and acid-etched surface reduces loosening of medial column fusion bolt in instable Charcot foot</atitle><jtitle>Foot and ankle surgery</jtitle><addtitle>Foot Ankle Surg</addtitle><date>2020-08</date><risdate>2020</risdate><volume>26</volume><issue>6</issue><spage>637</spage><epage>643</epage><pages>637-643</pages><issn>1268-7731</issn><eissn>1460-9584</eissn><abstract>•Bony consolidation of fusion sites is improved using surface modified medial column fusion bolt in Charcot foot.•Despite an initial restoration of the foot arch in both groups loss of correction was seen in controls only.•Frequency of adverse events like bolt dislocation and bolt breakage was reduced. Intramedullary fusion bolts (FB) were introduced to stabilize the medial column of the instable Charcot foot (ICF), but complications as bolt loosening or breakage are frequent. We compared the use of a standard FB and a high-profile threaded FB with a grit-blasted surface. We hypothesized that implant related complications occurred less often and osseous consolidation of fusion sites was more distinctive using the latter type of FB. Consecutive patients suffering from an ICF were stabilized with a high-profile threaded and surface-modified FB (HTFB) (n=20) or with a standard FB (n=20) which was placed into the first ray. Additional bolts and dorsal low-profile plates were applied in every patient. In a retrospective assessment osseous consolidation of the fusion sites was analyzed at 3 month and quantified by CT scan. At 3 and 12 month longitudinal foot arch collapse and rate of bolt loosening were assessed. Compared to the control group, the HTFB group reached significant higher consolidation after 3 month. No dislocation and a single bolt breakage was observed in the HTFB group after the fourth month, while the control group included 3 patients with bolt dislocation at 3±1 month and 5 patients with bolt breakage at 6±1.8 month. Compared to preoperative values, the improvement of Meary’s angle after one-year was significant higher in the HTFB group (23.4°±14) than in controls (11.7°±13). Modification of bolt design improves the stability of the medial column: A higher rate of osseous consolidation of the medial column leads to lower rate of bolt dislocation/breakage and finally to permanently erected longitudinal foot arch. Initially disappointing results following medial column stabilization with fusion bolts can be rejected by modifications of bolt design and its technical application.</abstract><cop>France</cop><pub>Elsevier Ltd</pub><pmid>31521519</pmid><doi>10.1016/j.fas.2019.08.004</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0003-1122-1303</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1268-7731
ispartof Foot and ankle surgery, 2020-08, Vol.26 (6), p.637-643
issn 1268-7731
1460-9584
language eng
recordid cdi_proquest_miscellaneous_2290975910
source Elsevier
subjects Arthrodesis - instrumentation
Arthropathy, Neurogenic - diagnostic imaging
Arthropathy, Neurogenic - surgery
Bone Nails
Case-Control Studies
Charcot foot
Diabetes mellitus
Female
Foot Bones - diagnostic imaging
Foot Bones - surgery
Foot Joints - diagnostic imaging
Foot Joints - surgery
Fusion bolt
Humans
Male
Middle Aged
Osseointegration
Surface Properties
Tomography, X-Ray Computed
title A high-profile thread with grit-blasted and acid-etched surface reduces loosening of medial column fusion bolt in instable Charcot foot
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T20%3A40%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20high-profile%20thread%20with%20grit-blasted%20and%20acid-etched%20surface%20reduces%20loosening%20of%20medial%20column%20fusion%20bolt%20in%20instable%20Charcot%20foot&rft.jtitle=Foot%20and%20ankle%20surgery&rft.au=Mehlhorn,%20Alexander%20T.&rft.date=2020-08&rft.volume=26&rft.issue=6&rft.spage=637&rft.epage=643&rft.pages=637-643&rft.issn=1268-7731&rft.eissn=1460-9584&rft_id=info:doi/10.1016/j.fas.2019.08.004&rft_dat=%3Cproquest_cross%3E2290975910%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c353t-605912d4f252c0165369e518af6ec9b9fc89e263fadc0ea3092d53ab1d8d5dc43%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2290975910&rft_id=info:pmid/31521519&rfr_iscdi=true