Loading…

2 MeV Electron Irradiation Effects in (HG,CD) TE CCDS

The effects of 2 MeV electrons, up to a dose of 105 rad(ZnS), on DC biased and continuously operating (Hg, Cd)Te charge-coupled devices (CCDs) at 77 K are discussed. Radiation induced flatband shifts were observed to be proportional to the electric field in the gate insulator. Typical flatband volta...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on nuclear science 1983-01, Vol.30 (6), p.4209-4215
Main Authors: Waterman, James R., Killiany, Joseph M.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c334t-4e2c50638b7d28a6151373df60e1e6dcff7f06657ad42cc3a5ecc035eb0a2f153
cites cdi_FETCH-LOGICAL-c334t-4e2c50638b7d28a6151373df60e1e6dcff7f06657ad42cc3a5ecc035eb0a2f153
container_end_page 4215
container_issue 6
container_start_page 4209
container_title IEEE transactions on nuclear science
container_volume 30
creator Waterman, James R.
Killiany, Joseph M.
description The effects of 2 MeV electrons, up to a dose of 105 rad(ZnS), on DC biased and continuously operating (Hg, Cd)Te charge-coupled devices (CCDs) at 77 K are discussed. Radiation induced flatband shifts were observed to be proportional to the electric field in the gate insulator. Typical flatband voltage shifts for thick insulator areas of the device were 3 volts for a dose of l×104 rad (ZnS). Degradation in CCD performance characteristics was observed in devices which were irradiated during operation. This degradation is attributed to flatband shifts. No increase in interface state density was observed. After 104 rad(ZnS), charge transfer efficiency and 'effective' full well capacity had degraded from pre-irradiation values of .996 and 8×1011/cm2 to .992 and 4×1011/cm2, respectively. Charge collected during a 1 msec integration of the dark current had increased by a factor of three from a pre-irradiation value of 1.2x1011/cm2 to 3.8×1011/cm2.
doi_str_mv 10.1109/TNS.1983.4333110
format article
fullrecord <record><control><sourceid>proquest_ieee_</sourceid><recordid>TN_cdi_proquest_miscellaneous_23115208</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4333110</ieee_id><sourcerecordid>23115208</sourcerecordid><originalsourceid>FETCH-LOGICAL-c334t-4e2c50638b7d28a6151373df60e1e6dcff7f06657ad42cc3a5ecc035eb0a2f153</originalsourceid><addsrcrecordid>eNo9kDFPwzAQhS0EEqWwI7F4QiCRcrbjxBlRGtpKBYYWVst1zlJQ2hQ7Hfj3ddXCdHfv3jvpPkJuGYwYg-J5-b4YsUKJUSqEiMoZGTApVcJkrs7JAICppEiL4pJchfAdx1SCHBDJ6Rt-0apF2_tuQ2fem7oxfRP7yrmoBtps6MN08lSOH-myomU5XlyTC2fagDenOiSfr9WynCbzj8msfJknVoi0T1LkVkIm1CqvuTIZk0zkonYZIMOsts7lDrJM5qZOubXCSLQWhMQVGO6YFENyf7y79d3PDkOv102w2LZmg90uaB4_lRxUNMLRaH0Xgkent75ZG_-rGegDHx356AMffeITI3fHSIOI__a_7R5KMV2d</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>23115208</pqid></control><display><type>article</type><title>2 MeV Electron Irradiation Effects in (HG,CD) TE CCDS</title><source>IEEE Electronic Library (IEL) Journals</source><creator>Waterman, James R. ; Killiany, Joseph M.</creator><creatorcontrib>Waterman, James R. ; Killiany, Joseph M.</creatorcontrib><description>The effects of 2 MeV electrons, up to a dose of 105 rad(ZnS), on DC biased and continuously operating (Hg, Cd)Te charge-coupled devices (CCDs) at 77 K are discussed. Radiation induced flatband shifts were observed to be proportional to the electric field in the gate insulator. Typical flatband voltage shifts for thick insulator areas of the device were 3 volts for a dose of l×104 rad (ZnS). Degradation in CCD performance characteristics was observed in devices which were irradiated during operation. This degradation is attributed to flatband shifts. No increase in interface state density was observed. After 104 rad(ZnS), charge transfer efficiency and 'effective' full well capacity had degraded from pre-irradiation values of .996 and 8×1011/cm2 to .992 and 4×1011/cm2, respectively. Charge collected during a 1 msec integration of the dark current had increased by a factor of three from a pre-irradiation value of 1.2x1011/cm2 to 3.8×1011/cm2.</description><identifier>ISSN: 0018-9499</identifier><identifier>EISSN: 1558-1578</identifier><identifier>DOI: 10.1109/TNS.1983.4333110</identifier><identifier>CODEN: IETNAE</identifier><language>eng</language><publisher>IEEE</publisher><subject>Charge coupled devices ; Charge transfer ; Degradation ; Dielectrics and electrical insulation ; Electrons ; Interface states ; Mercury (metals) ; Tellurium ; Voltage ; Zinc compounds</subject><ispartof>IEEE transactions on nuclear science, 1983-01, Vol.30 (6), p.4209-4215</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c334t-4e2c50638b7d28a6151373df60e1e6dcff7f06657ad42cc3a5ecc035eb0a2f153</citedby><cites>FETCH-LOGICAL-c334t-4e2c50638b7d28a6151373df60e1e6dcff7f06657ad42cc3a5ecc035eb0a2f153</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4333110$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,776,780,27903,27904,54774</link.rule.ids></links><search><creatorcontrib>Waterman, James R.</creatorcontrib><creatorcontrib>Killiany, Joseph M.</creatorcontrib><title>2 MeV Electron Irradiation Effects in (HG,CD) TE CCDS</title><title>IEEE transactions on nuclear science</title><addtitle>TNS</addtitle><description>The effects of 2 MeV electrons, up to a dose of 105 rad(ZnS), on DC biased and continuously operating (Hg, Cd)Te charge-coupled devices (CCDs) at 77 K are discussed. Radiation induced flatband shifts were observed to be proportional to the electric field in the gate insulator. Typical flatband voltage shifts for thick insulator areas of the device were 3 volts for a dose of l×104 rad (ZnS). Degradation in CCD performance characteristics was observed in devices which were irradiated during operation. This degradation is attributed to flatband shifts. No increase in interface state density was observed. After 104 rad(ZnS), charge transfer efficiency and 'effective' full well capacity had degraded from pre-irradiation values of .996 and 8×1011/cm2 to .992 and 4×1011/cm2, respectively. Charge collected during a 1 msec integration of the dark current had increased by a factor of three from a pre-irradiation value of 1.2x1011/cm2 to 3.8×1011/cm2.</description><subject>Charge coupled devices</subject><subject>Charge transfer</subject><subject>Degradation</subject><subject>Dielectrics and electrical insulation</subject><subject>Electrons</subject><subject>Interface states</subject><subject>Mercury (metals)</subject><subject>Tellurium</subject><subject>Voltage</subject><subject>Zinc compounds</subject><issn>0018-9499</issn><issn>1558-1578</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1983</creationdate><recordtype>article</recordtype><recordid>eNo9kDFPwzAQhS0EEqWwI7F4QiCRcrbjxBlRGtpKBYYWVst1zlJQ2hQ7Hfj3ddXCdHfv3jvpPkJuGYwYg-J5-b4YsUKJUSqEiMoZGTApVcJkrs7JAICppEiL4pJchfAdx1SCHBDJ6Rt-0apF2_tuQ2fem7oxfRP7yrmoBtps6MN08lSOH-myomU5XlyTC2fagDenOiSfr9WynCbzj8msfJknVoi0T1LkVkIm1CqvuTIZk0zkonYZIMOsts7lDrJM5qZOubXCSLQWhMQVGO6YFENyf7y79d3PDkOv102w2LZmg90uaB4_lRxUNMLRaH0Xgkent75ZG_-rGegDHx356AMffeITI3fHSIOI__a_7R5KMV2d</recordid><startdate>19830101</startdate><enddate>19830101</enddate><creator>Waterman, James R.</creator><creator>Killiany, Joseph M.</creator><general>IEEE</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>19830101</creationdate><title>2 MeV Electron Irradiation Effects in (HG,CD) TE CCDS</title><author>Waterman, James R. ; Killiany, Joseph M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c334t-4e2c50638b7d28a6151373df60e1e6dcff7f06657ad42cc3a5ecc035eb0a2f153</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1983</creationdate><topic>Charge coupled devices</topic><topic>Charge transfer</topic><topic>Degradation</topic><topic>Dielectrics and electrical insulation</topic><topic>Electrons</topic><topic>Interface states</topic><topic>Mercury (metals)</topic><topic>Tellurium</topic><topic>Voltage</topic><topic>Zinc compounds</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Waterman, James R.</creatorcontrib><creatorcontrib>Killiany, Joseph M.</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>IEEE transactions on nuclear science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Waterman, James R.</au><au>Killiany, Joseph M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>2 MeV Electron Irradiation Effects in (HG,CD) TE CCDS</atitle><jtitle>IEEE transactions on nuclear science</jtitle><stitle>TNS</stitle><date>1983-01-01</date><risdate>1983</risdate><volume>30</volume><issue>6</issue><spage>4209</spage><epage>4215</epage><pages>4209-4215</pages><issn>0018-9499</issn><eissn>1558-1578</eissn><coden>IETNAE</coden><abstract>The effects of 2 MeV electrons, up to a dose of 105 rad(ZnS), on DC biased and continuously operating (Hg, Cd)Te charge-coupled devices (CCDs) at 77 K are discussed. Radiation induced flatband shifts were observed to be proportional to the electric field in the gate insulator. Typical flatband voltage shifts for thick insulator areas of the device were 3 volts for a dose of l×104 rad (ZnS). Degradation in CCD performance characteristics was observed in devices which were irradiated during operation. This degradation is attributed to flatband shifts. No increase in interface state density was observed. After 104 rad(ZnS), charge transfer efficiency and 'effective' full well capacity had degraded from pre-irradiation values of .996 and 8×1011/cm2 to .992 and 4×1011/cm2, respectively. Charge collected during a 1 msec integration of the dark current had increased by a factor of three from a pre-irradiation value of 1.2x1011/cm2 to 3.8×1011/cm2.</abstract><pub>IEEE</pub><doi>10.1109/TNS.1983.4333110</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0018-9499
ispartof IEEE transactions on nuclear science, 1983-01, Vol.30 (6), p.4209-4215
issn 0018-9499
1558-1578
language eng
recordid cdi_proquest_miscellaneous_23115208
source IEEE Electronic Library (IEL) Journals
subjects Charge coupled devices
Charge transfer
Degradation
Dielectrics and electrical insulation
Electrons
Interface states
Mercury (metals)
Tellurium
Voltage
Zinc compounds
title 2 MeV Electron Irradiation Effects in (HG,CD) TE CCDS
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T16%3A22%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=2%20MeV%20Electron%20Irradiation%20Effects%20in%20(HG,CD)%20TE%20CCDS&rft.jtitle=IEEE%20transactions%20on%20nuclear%20science&rft.au=Waterman,%20James%20R.&rft.date=1983-01-01&rft.volume=30&rft.issue=6&rft.spage=4209&rft.epage=4215&rft.pages=4209-4215&rft.issn=0018-9499&rft.eissn=1558-1578&rft.coden=IETNAE&rft_id=info:doi/10.1109/TNS.1983.4333110&rft_dat=%3Cproquest_ieee_%3E23115208%3C/proquest_ieee_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c334t-4e2c50638b7d28a6151373df60e1e6dcff7f06657ad42cc3a5ecc035eb0a2f153%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=23115208&rft_id=info:pmid/&rft_ieee_id=4333110&rfr_iscdi=true