Timing of intraventricular infusion test for diagnosing idiopathic normal pressure hydrocephalus
Background Infusion tests, which measure resistance to outflow (R out ), are used in selecting patients suspected for idiopathic normal pressure hydrocephalus (iNPH) for shunt surgery. Infusion tests can be performed through an external ventricular drain (EVD). A 24-hour time gap from EVD insertion...
Saved in:
Published in: | Acta neurochirurgica 2020-05, Vol.162 (5), p.1011-1017 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Background
Infusion tests, which measure resistance to outflow (R
out
), are used in selecting patients suspected for idiopathic normal pressure hydrocephalus (iNPH) for shunt surgery. Infusion tests can be performed through an external ventricular drain (EVD). A 24-hour time gap from EVD insertion to an infusion test is a routine practice at our department due to concerns that the surgical procedure might influence the test results in the immediate postoperative period. The objective of the study was to investigate if timing of an intraventricular infusion test influences the results of the test in patients suspected for iNPH.
Methods
Ten patients scheduled for an intraventricular infusion test were included. Measurements of baseline intracranial pressure (ICP) and plateau ICP were obtained during constant rate intraventricular infusion test performed at two time points (1 and 24 h after EVD insertion) and R
out
was calculated from these measures and compared within patients.
Results
Eight patients completed both infusion tests. In one of the 18 infusion tests performed, it was not possible to define an ICP plateau and this infusion test was excluded, leaving 7 paired infusion tests. Median R
out
was 12.9 mmHg/ml/min (range 7.0–22.0) 1 h after EVD insertion and 11.3 mmHg/ml/min (range 7.8–18.1) after 24 h. Overall, there were no statistically significant differences in R
out
(
P
= 0.83), baseline ICP (
P
= 0.70), or plateau ICP (
P
= 0.81) between the recordings performed 1 h and 24 h after EVD insertion. For two of the seven patients with paired infusion tests, there was poor agreement between R
out
values at 1 and 24 h.
Conclusion
Overall, R
out
estimates do not change significantly between 1 and 24 h after EVD insertion. We therefore propose that infusion tests can be performed shortly after surgery to reduce the period of indwelling EVD and duration of hospitalization. |
---|---|