A four-class brain-computer interface (BCI) system based on steady-state visual evoked potentials (SSVEPs) was developed by presenting phase-coded 60Hz stimulations on a 240Hz LCD monitor. The task-related component analysis (TRCA) algorithm was used to detect SSVEPs with individual training data. I...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A four-class brain-computer interface (BCI) system based on steady-state visual evoked potentials (SSVEPs) was developed by presenting phase-coded 60Hz stimulations on a 240Hz LCD monitor. The task-related component analysis (TRCA) algorithm was used to detect SSVEPs with individual training data. In the BCI experiment with 10 subjects, the system achieved high classification accuracy of 94.50±6.70% and 92.71±7.56% in offline and online BCI experiments, resulting in information transfer rates (ITR) of 19.95±4.36 and 18.81±4.74 bpm, respectively. The behavioral tests on visual comfortableness and perception of flickering reveal that the proposed BCI system is very comfortable to use without any perception of flicker. |
---|---|
ISSN: | 1558-4615 2694-0604 |
DOI: | 10.1109/EMBC.2019.8857326 |