Loading…

Causality-constrained measurements of aural acoustic reflectance and reflection functions

Causality-constrained procedures are described to measure acoustic pressure reflectance and reflection function (RF) in the ear canal or unknown waveguide, in which reflectance is the Fourier transform of the RF. Reflectance calibration is reformulated to generate causal outputs, with results descri...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of the Acoustical Society of America 2020-01, Vol.147 (1), p.300-324
Main Author: Keefe, Douglas H.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c359t-a68980317226824c6b3a60eaad8d71aec5a0597e8a2fae4eac194a5af497dd253
cites cdi_FETCH-LOGICAL-c359t-a68980317226824c6b3a60eaad8d71aec5a0597e8a2fae4eac194a5af497dd253
container_end_page 324
container_issue 1
container_start_page 300
container_title The Journal of the Acoustical Society of America
container_volume 147
creator Keefe, Douglas H.
description Causality-constrained procedures are described to measure acoustic pressure reflectance and reflection function (RF) in the ear canal or unknown waveguide, in which reflectance is the Fourier transform of the RF. Reflectance calibration is reformulated to generate causal outputs, with results described for a calibration based on a reflectance waveguide equation to calculate incident pressure and source reflectance in the frequency domain or source RF in the time domain. The viscothermal model RF of each tube is band-limited to the stimulus bandwidth. Results are described in which incident pressure is either known from long-tube measurements or calculated as a calibration output. Calibrations based on constrained nonlinear optimizations are simpler and more accurate when incident pressure is known. Outputs measured by causality-constrained procedures differ at higher frequencies from those using standard procedures with non-causal outputs. Evanescent-mode effects formulated in the time domain and incorporated into frequency-domain calibrations are negligible for long-tube calibrations. Causal reflectance and RFs are evaluated in an adult ear canal and time- and frequency-domain results are contrasted using forward and inverse Fourier transforms. These results contribute to the long-term goals of improving applications to calibrate sound stimuli in the ear canal at high frequencies and diagnose conductive hearing impairments.
doi_str_mv 10.1121/10.0000588
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_2350351270</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2350351270</sourcerecordid><originalsourceid>FETCH-LOGICAL-c359t-a68980317226824c6b3a60eaad8d71aec5a0597e8a2fae4eac194a5af497dd253</originalsourceid><addsrcrecordid>eNp9kEtLxDAUhYMoOo5u_AHSpSjVPJo2WcrgCwbc6MJVuZPcQqVNxyQV_PdmHg4uxGxObvg49-QQcsboNWOc3SSl6Uil9siESU5zJXmxTybpkeWFLssjchzC-5oR-pAcCU5pqaWekLcZjAG6Nn7lZnAhemgd2qxHCKPHHl0M2dBkMHroMjDDGGJrMo9NhyaCM5iBsz9zO7isGd36Ek7IQQNdwNOtTsnr_d3L7DGfPz88zW7nuRFSxxxKpRUVrOK8VLww5UJASRHAKlsxQCOBSl2hAt4AFgiG6QIkNIWurOVSTMnFxnfph48RQ6z7NhjsOnCY4tZcSCok4xVN6OUGNX4IIYWul77twX_VjNarKle6rTLB51vfcdGj3aE_3SXgagME00ZY_XnHfA7-l1W9tM1_9B_LvwEE1ov4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2350351270</pqid></control><display><type>article</type><title>Causality-constrained measurements of aural acoustic reflectance and reflection functions</title><source>American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)</source><creator>Keefe, Douglas H.</creator><creatorcontrib>Keefe, Douglas H.</creatorcontrib><description>Causality-constrained procedures are described to measure acoustic pressure reflectance and reflection function (RF) in the ear canal or unknown waveguide, in which reflectance is the Fourier transform of the RF. Reflectance calibration is reformulated to generate causal outputs, with results described for a calibration based on a reflectance waveguide equation to calculate incident pressure and source reflectance in the frequency domain or source RF in the time domain. The viscothermal model RF of each tube is band-limited to the stimulus bandwidth. Results are described in which incident pressure is either known from long-tube measurements or calculated as a calibration output. Calibrations based on constrained nonlinear optimizations are simpler and more accurate when incident pressure is known. Outputs measured by causality-constrained procedures differ at higher frequencies from those using standard procedures with non-causal outputs. Evanescent-mode effects formulated in the time domain and incorporated into frequency-domain calibrations are negligible for long-tube calibrations. Causal reflectance and RFs are evaluated in an adult ear canal and time- and frequency-domain results are contrasted using forward and inverse Fourier transforms. These results contribute to the long-term goals of improving applications to calibrate sound stimuli in the ear canal at high frequencies and diagnose conductive hearing impairments.</description><identifier>ISSN: 0001-4966</identifier><identifier>EISSN: 1520-8524</identifier><identifier>DOI: 10.1121/10.0000588</identifier><identifier>PMID: 32006959</identifier><identifier>CODEN: JASMAN</identifier><language>eng</language><publisher>United States</publisher><subject>Acoustic Impedance Tests ; Acoustic Stimulation ; Acoustics ; Ear Canal - physiology ; Hearing - physiology ; Humans ; Models, Theoretical ; Signal Processing, Computer-Assisted ; Sound</subject><ispartof>The Journal of the Acoustical Society of America, 2020-01, Vol.147 (1), p.300-324</ispartof><rights>Acoustical Society of America</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c359t-a68980317226824c6b3a60eaad8d71aec5a0597e8a2fae4eac194a5af497dd253</citedby><cites>FETCH-LOGICAL-c359t-a68980317226824c6b3a60eaad8d71aec5a0597e8a2fae4eac194a5af497dd253</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32006959$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Keefe, Douglas H.</creatorcontrib><title>Causality-constrained measurements of aural acoustic reflectance and reflection functions</title><title>The Journal of the Acoustical Society of America</title><addtitle>J Acoust Soc Am</addtitle><description>Causality-constrained procedures are described to measure acoustic pressure reflectance and reflection function (RF) in the ear canal or unknown waveguide, in which reflectance is the Fourier transform of the RF. Reflectance calibration is reformulated to generate causal outputs, with results described for a calibration based on a reflectance waveguide equation to calculate incident pressure and source reflectance in the frequency domain or source RF in the time domain. The viscothermal model RF of each tube is band-limited to the stimulus bandwidth. Results are described in which incident pressure is either known from long-tube measurements or calculated as a calibration output. Calibrations based on constrained nonlinear optimizations are simpler and more accurate when incident pressure is known. Outputs measured by causality-constrained procedures differ at higher frequencies from those using standard procedures with non-causal outputs. Evanescent-mode effects formulated in the time domain and incorporated into frequency-domain calibrations are negligible for long-tube calibrations. Causal reflectance and RFs are evaluated in an adult ear canal and time- and frequency-domain results are contrasted using forward and inverse Fourier transforms. These results contribute to the long-term goals of improving applications to calibrate sound stimuli in the ear canal at high frequencies and diagnose conductive hearing impairments.</description><subject>Acoustic Impedance Tests</subject><subject>Acoustic Stimulation</subject><subject>Acoustics</subject><subject>Ear Canal - physiology</subject><subject>Hearing - physiology</subject><subject>Humans</subject><subject>Models, Theoretical</subject><subject>Signal Processing, Computer-Assisted</subject><subject>Sound</subject><issn>0001-4966</issn><issn>1520-8524</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9kEtLxDAUhYMoOo5u_AHSpSjVPJo2WcrgCwbc6MJVuZPcQqVNxyQV_PdmHg4uxGxObvg49-QQcsboNWOc3SSl6Uil9siESU5zJXmxTybpkeWFLssjchzC-5oR-pAcCU5pqaWekLcZjAG6Nn7lZnAhemgd2qxHCKPHHl0M2dBkMHroMjDDGGJrMo9NhyaCM5iBsz9zO7isGd36Ek7IQQNdwNOtTsnr_d3L7DGfPz88zW7nuRFSxxxKpRUVrOK8VLww5UJASRHAKlsxQCOBSl2hAt4AFgiG6QIkNIWurOVSTMnFxnfph48RQ6z7NhjsOnCY4tZcSCok4xVN6OUGNX4IIYWul77twX_VjNarKle6rTLB51vfcdGj3aE_3SXgagME00ZY_XnHfA7-l1W9tM1_9B_LvwEE1ov4</recordid><startdate>202001</startdate><enddate>202001</enddate><creator>Keefe, Douglas H.</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202001</creationdate><title>Causality-constrained measurements of aural acoustic reflectance and reflection functions</title><author>Keefe, Douglas H.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c359t-a68980317226824c6b3a60eaad8d71aec5a0597e8a2fae4eac194a5af497dd253</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Acoustic Impedance Tests</topic><topic>Acoustic Stimulation</topic><topic>Acoustics</topic><topic>Ear Canal - physiology</topic><topic>Hearing - physiology</topic><topic>Humans</topic><topic>Models, Theoretical</topic><topic>Signal Processing, Computer-Assisted</topic><topic>Sound</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Keefe, Douglas H.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of the Acoustical Society of America</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Keefe, Douglas H.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Causality-constrained measurements of aural acoustic reflectance and reflection functions</atitle><jtitle>The Journal of the Acoustical Society of America</jtitle><addtitle>J Acoust Soc Am</addtitle><date>2020-01</date><risdate>2020</risdate><volume>147</volume><issue>1</issue><spage>300</spage><epage>324</epage><pages>300-324</pages><issn>0001-4966</issn><eissn>1520-8524</eissn><coden>JASMAN</coden><abstract>Causality-constrained procedures are described to measure acoustic pressure reflectance and reflection function (RF) in the ear canal or unknown waveguide, in which reflectance is the Fourier transform of the RF. Reflectance calibration is reformulated to generate causal outputs, with results described for a calibration based on a reflectance waveguide equation to calculate incident pressure and source reflectance in the frequency domain or source RF in the time domain. The viscothermal model RF of each tube is band-limited to the stimulus bandwidth. Results are described in which incident pressure is either known from long-tube measurements or calculated as a calibration output. Calibrations based on constrained nonlinear optimizations are simpler and more accurate when incident pressure is known. Outputs measured by causality-constrained procedures differ at higher frequencies from those using standard procedures with non-causal outputs. Evanescent-mode effects formulated in the time domain and incorporated into frequency-domain calibrations are negligible for long-tube calibrations. Causal reflectance and RFs are evaluated in an adult ear canal and time- and frequency-domain results are contrasted using forward and inverse Fourier transforms. These results contribute to the long-term goals of improving applications to calibrate sound stimuli in the ear canal at high frequencies and diagnose conductive hearing impairments.</abstract><cop>United States</cop><pmid>32006959</pmid><doi>10.1121/10.0000588</doi><tpages>25</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0001-4966
ispartof The Journal of the Acoustical Society of America, 2020-01, Vol.147 (1), p.300-324
issn 0001-4966
1520-8524
language eng
recordid cdi_proquest_miscellaneous_2350351270
source American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)
subjects Acoustic Impedance Tests
Acoustic Stimulation
Acoustics
Ear Canal - physiology
Hearing - physiology
Humans
Models, Theoretical
Signal Processing, Computer-Assisted
Sound
title Causality-constrained measurements of aural acoustic reflectance and reflection functions
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T13%3A45%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Causality-constrained%20measurements%20of%20aural%20acoustic%20reflectance%20and%20reflection%20functions&rft.jtitle=The%20Journal%20of%20the%20Acoustical%20Society%20of%20America&rft.au=Keefe,%20Douglas%20H.&rft.date=2020-01&rft.volume=147&rft.issue=1&rft.spage=300&rft.epage=324&rft.pages=300-324&rft.issn=0001-4966&rft.eissn=1520-8524&rft.coden=JASMAN&rft_id=info:doi/10.1121/10.0000588&rft_dat=%3Cproquest_pubme%3E2350351270%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c359t-a68980317226824c6b3a60eaad8d71aec5a0597e8a2fae4eac194a5af497dd253%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2350351270&rft_id=info:pmid/32006959&rfr_iscdi=true