Loading…
A multicentre outbreak of ST45 MRSA containing deletions in the spa gene in New South Wales, Australia
Abstract Background Early identification of MRSA by diagnostic medical microbiology laboratories enables improved antimicrobial choice and outcomes. The Cepheid Xpert® MRSA/SA BC test rapidly identifies Staphylococcus aureus bloodstream infections through spa gene detection and methicillin resistanc...
Saved in:
Published in: | Journal of antimicrobial chemotherapy 2020-05, Vol.75 (5), p.1112-1116 |
---|---|
Main Authors: | , , , , , , , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Abstract
Background
Early identification of MRSA by diagnostic medical microbiology laboratories enables improved antimicrobial choice and outcomes. The Cepheid Xpert® MRSA/SA BC test rapidly identifies Staphylococcus aureus bloodstream infections through spa gene detection and methicillin resistance via mecA gene detection. Recent emergence of S. aureus with deletions in the spa gene has resulted in false-negative results for this test, leading to misidentification of infections with this organism, particularly MRSA ST45.
Objectives
To investigate the emergence and prevalence of ST45 MRSA in New South Wales (NSW), Australia.
Methods
WGS read data from six NSW hospitals were collected for 131 ST45 MRSA isolates and analysed.
Results
Of the 131 ST45 MRSA investigated, 88.5% (116/131) contained a deletion in the spa gene that appeared to have arisen once in approximately 2010 followed by clonal expansion. Given the successful establishment of this ‘spa-deletion’ MRSA clone, the Cepheid Xpert® MRSA/SA BC test became unreliable for confirming S. aureus bacteraemia in NSW. Subsequently, the algorithm used by this test has been updated and evaluated to take into account the presence of S. aureus with either a spa deletion or SCCmec target variations.
Conclusions
This study highlighted the applied use of WGS for assessing diagnostic assays and informing necessary changes to ensure the viability of the Cepheid Xpert® MRSA/SA BC test in the context of the new ‘spa-deletion’ MRSA clone. It demonstrated how continued surveillance through WGS can reveal evolutionary events that may impact diagnostic assays, allowing corrective modifications to be made in real time. |
---|---|
ISSN: | 0305-7453 1460-2091 |
DOI: | 10.1093/jac/dkz560 |