Loading…

Theoretical and experimental study of the LR-115 detector response in a non-commercial radon monitor

B.trαcks, a simulation program for SSNTD's sensitivity, has been developed to study the response of LR-115 (cellulose nitrate) and CR-39 (poly allyl glycol carbonate) nuclear track detectors. Detectors are located inside detector holders and are used for radon measurements. The program incorpor...

Full description

Saved in:
Bibliographic Details
Published in:Applied radiation and isotopes 2020-06, Vol.160, p.109112-109112, Article 109112
Main Authors: Pérez, B., López, M.E., Palacios, D.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:B.trαcks, a simulation program for SSNTD's sensitivity, has been developed to study the response of LR-115 (cellulose nitrate) and CR-39 (poly allyl glycol carbonate) nuclear track detectors. Detectors are located inside detector holders and are used for radon measurements. The program incorporates a variety of special features gathered together to achieve good agreement between theoretical approach and experimental results. The input parameters to study the detector response are radon exposure, geometry and dimensions of a detector holder (it can be cylindrical, conical or semi-spherical), entrance type for radon gas, detector type, and V function (four different functions were selected from literature). The output results are detector response and radon progeny distribution onto internal chamber walls. In this article, the response of the LR-115, which is placed inside a non-commercial-conductive radon monitor based on diffusion chambers called G2, was theoretically and experimentally studied. The common Monte Carlo simulation procedure and an alternative approach that replicates how monitors are exposed to different radon exposures were used as theoretical approaches. Experimental methodology was conducted in a radon test chamber from Italy (MI.AM s.r.l.). Comparison results of both theoretical and experimental methodology are presented and discussed. One of the major results, among others, shows that the monitor material (conductive or non-conductive) does not influence the LR-115 response. •As theoretical approaches, two different simulation models are used.•Theoretical approaches are developed by using Monte Carlo methods.•The theoretical and experimental LR-115 detector response are discussed.•Different V functions are used in order to study the theoretical LR-115 detector response.
ISSN:0969-8043
1872-9800
DOI:10.1016/j.apradiso.2020.109112