Loading…

Evaluation of a metal artifact reduction algorithm and an optimization filter in the estimation of peri-implant dehiscence defects by using cone beam computed tomography: an in-vitro study

The aim of this study was to assess the effect of a metal artifact reduction (MAR) algorithm and the adaptive image noise optimizer (AINO) optimization filter in the detection of peri-implant dehiscences with cone beam computed tomography (CBCT). Nine implants (3 zirconium, 3 titanium, and 3 zirconi...

Full description

Saved in:
Bibliographic Details
Published in:Oral surgery, oral medicine, oral pathology and oral radiology oral medicine, oral pathology and oral radiology, 2020-08, Vol.130 (2), p.209-216
Main Authors: Bayrak, Seval, Orhan, Kaan, Kursun Çakmak, Emine Sebnem, Görürgöz, Cansu, Odabaşı, Onur, Yilmaz, Dervis, Atakan, Cemal
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c422t-58bc8db9582a8ddcd0ef590cce6bf9ab5fd06b74721830fce7348cc032995a5d3
cites cdi_FETCH-LOGICAL-c422t-58bc8db9582a8ddcd0ef590cce6bf9ab5fd06b74721830fce7348cc032995a5d3
container_end_page 216
container_issue 2
container_start_page 209
container_title Oral surgery, oral medicine, oral pathology and oral radiology
container_volume 130
creator Bayrak, Seval
Orhan, Kaan
Kursun Çakmak, Emine Sebnem
Görürgöz, Cansu
Odabaşı, Onur
Yilmaz, Dervis
Atakan, Cemal
description The aim of this study was to assess the effect of a metal artifact reduction (MAR) algorithm and the adaptive image noise optimizer (AINO) optimization filter in the detection of peri-implant dehiscences with cone beam computed tomography (CBCT). Nine implants (3 zirconium, 3 titanium, and 3 zirconium-titanium) were placed in 3 sheep heads. Dehiscences were created on the buccal and lingual/palatal surfaces. A total of 9 defects and 9 controls with no defects were evaluated by 3 observers. Each sheep head was scanned 5 times with 4 scan modes; (1) without MAR/without AINO; (2) with MAR/without AINO; (3) without MAR/with AINO; and (4) with MAR/with AINO. Receiver operating characteristic analysis and weighted kappa coefficients were used to calculate diagnostic efficacy and intra- and interobserver agreements for each implant type and scan mode. For all implant types, dehiscences were most accurately detected when both MAR and AINO were applied (P ≤ .045). Detection of dehiscences was more accurate with titanium implants (P ≤ .040). There were no significant differences in agreement among and between the observers. The use of both MAR and AINO enhanced the detection accuracy of artificially created dehiscences in proximity to implants. Their combined use is recommended for detecting peri-implant dehiscences.
doi_str_mv 10.1016/j.oooo.2020.02.005
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2381625315</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S2212440320300390</els_id><sourcerecordid>2381625315</sourcerecordid><originalsourceid>FETCH-LOGICAL-c422t-58bc8db9582a8ddcd0ef590cce6bf9ab5fd06b74721830fce7348cc032995a5d3</originalsourceid><addsrcrecordid>eNp9UcFu1DAQtRCIVqU_wAH5yCWp7cSJg7igqkClSlzgbDn2eNerOA62s9LybXwcDlv2yEiWR5r33ujNQ-gtJTUltLs71KFUzQgjNWE1IfwFumaMsqptKX156UlzhW5TOpBSXSG27DW6ahgdetGLa_T74aimVWUXZhwsVthDVhNWMTurdMYRzKr_TtW0C9HlvcdqNuXhsGTn3a8z17opQ8RuxnkPGFIZXUQXiK5yfpnUnLGBvUsaZg2ltaBzwuMJr8nNO6zDDHgE5UvnlzWDwTn4sItq2Z8-bDvdXB1djgGnvJrTG_TKqinB7fN_g358fvh-_7V6-vbl8f7TU6VbxnLFxaiFGQcumBLGaEPA8oFoDd1oBzVya0g39m3PqGiI1dA3rdCaNGwYuOKmuUHvz7pLDD_XYk76zcNUDEFYk2SNoB3jDeUFys5QHUNKEaxcYjlFPElK5BacPMgtOLkFJwmTJbhCevesv44ezIXyL6YC-HgGQHF5dBBl0m67oXGxnFCa4P6n_wecK68G</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2381625315</pqid></control><display><type>article</type><title>Evaluation of a metal artifact reduction algorithm and an optimization filter in the estimation of peri-implant dehiscence defects by using cone beam computed tomography: an in-vitro study</title><source>ScienceDirect Journals</source><creator>Bayrak, Seval ; Orhan, Kaan ; Kursun Çakmak, Emine Sebnem ; Görürgöz, Cansu ; Odabaşı, Onur ; Yilmaz, Dervis ; Atakan, Cemal</creator><creatorcontrib>Bayrak, Seval ; Orhan, Kaan ; Kursun Çakmak, Emine Sebnem ; Görürgöz, Cansu ; Odabaşı, Onur ; Yilmaz, Dervis ; Atakan, Cemal</creatorcontrib><description>The aim of this study was to assess the effect of a metal artifact reduction (MAR) algorithm and the adaptive image noise optimizer (AINO) optimization filter in the detection of peri-implant dehiscences with cone beam computed tomography (CBCT). Nine implants (3 zirconium, 3 titanium, and 3 zirconium-titanium) were placed in 3 sheep heads. Dehiscences were created on the buccal and lingual/palatal surfaces. A total of 9 defects and 9 controls with no defects were evaluated by 3 observers. Each sheep head was scanned 5 times with 4 scan modes; (1) without MAR/without AINO; (2) with MAR/without AINO; (3) without MAR/with AINO; and (4) with MAR/with AINO. Receiver operating characteristic analysis and weighted kappa coefficients were used to calculate diagnostic efficacy and intra- and interobserver agreements for each implant type and scan mode. For all implant types, dehiscences were most accurately detected when both MAR and AINO were applied (P ≤ .045). Detection of dehiscences was more accurate with titanium implants (P ≤ .040). There were no significant differences in agreement among and between the observers. The use of both MAR and AINO enhanced the detection accuracy of artificially created dehiscences in proximity to implants. Their combined use is recommended for detecting peri-implant dehiscences.</description><identifier>ISSN: 2212-4403</identifier><identifier>EISSN: 2212-4411</identifier><identifier>DOI: 10.1016/j.oooo.2020.02.005</identifier><identifier>PMID: 32197878</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Dentistry</subject><ispartof>Oral surgery, oral medicine, oral pathology and oral radiology, 2020-08, Vol.130 (2), p.209-216</ispartof><rights>2020</rights><rights>Copyright © 2020. Published by Elsevier Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c422t-58bc8db9582a8ddcd0ef590cce6bf9ab5fd06b74721830fce7348cc032995a5d3</citedby><cites>FETCH-LOGICAL-c422t-58bc8db9582a8ddcd0ef590cce6bf9ab5fd06b74721830fce7348cc032995a5d3</cites><orcidid>0000-0001-7771-048X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32197878$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Bayrak, Seval</creatorcontrib><creatorcontrib>Orhan, Kaan</creatorcontrib><creatorcontrib>Kursun Çakmak, Emine Sebnem</creatorcontrib><creatorcontrib>Görürgöz, Cansu</creatorcontrib><creatorcontrib>Odabaşı, Onur</creatorcontrib><creatorcontrib>Yilmaz, Dervis</creatorcontrib><creatorcontrib>Atakan, Cemal</creatorcontrib><title>Evaluation of a metal artifact reduction algorithm and an optimization filter in the estimation of peri-implant dehiscence defects by using cone beam computed tomography: an in-vitro study</title><title>Oral surgery, oral medicine, oral pathology and oral radiology</title><addtitle>Oral Surg Oral Med Oral Pathol Oral Radiol</addtitle><description>The aim of this study was to assess the effect of a metal artifact reduction (MAR) algorithm and the adaptive image noise optimizer (AINO) optimization filter in the detection of peri-implant dehiscences with cone beam computed tomography (CBCT). Nine implants (3 zirconium, 3 titanium, and 3 zirconium-titanium) were placed in 3 sheep heads. Dehiscences were created on the buccal and lingual/palatal surfaces. A total of 9 defects and 9 controls with no defects were evaluated by 3 observers. Each sheep head was scanned 5 times with 4 scan modes; (1) without MAR/without AINO; (2) with MAR/without AINO; (3) without MAR/with AINO; and (4) with MAR/with AINO. Receiver operating characteristic analysis and weighted kappa coefficients were used to calculate diagnostic efficacy and intra- and interobserver agreements for each implant type and scan mode. For all implant types, dehiscences were most accurately detected when both MAR and AINO were applied (P ≤ .045). Detection of dehiscences was more accurate with titanium implants (P ≤ .040). There were no significant differences in agreement among and between the observers. The use of both MAR and AINO enhanced the detection accuracy of artificially created dehiscences in proximity to implants. Their combined use is recommended for detecting peri-implant dehiscences.</description><subject>Dentistry</subject><issn>2212-4403</issn><issn>2212-4411</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9UcFu1DAQtRCIVqU_wAH5yCWp7cSJg7igqkClSlzgbDn2eNerOA62s9LybXwcDlv2yEiWR5r33ujNQ-gtJTUltLs71KFUzQgjNWE1IfwFumaMsqptKX156UlzhW5TOpBSXSG27DW6ahgdetGLa_T74aimVWUXZhwsVthDVhNWMTurdMYRzKr_TtW0C9HlvcdqNuXhsGTn3a8z17opQ8RuxnkPGFIZXUQXiK5yfpnUnLGBvUsaZg2ltaBzwuMJr8nNO6zDDHgE5UvnlzWDwTn4sItq2Z8-bDvdXB1djgGnvJrTG_TKqinB7fN_g358fvh-_7V6-vbl8f7TU6VbxnLFxaiFGQcumBLGaEPA8oFoDd1oBzVya0g39m3PqGiI1dA3rdCaNGwYuOKmuUHvz7pLDD_XYk76zcNUDEFYk2SNoB3jDeUFys5QHUNKEaxcYjlFPElK5BacPMgtOLkFJwmTJbhCevesv44ezIXyL6YC-HgGQHF5dBBl0m67oXGxnFCa4P6n_wecK68G</recordid><startdate>20200801</startdate><enddate>20200801</enddate><creator>Bayrak, Seval</creator><creator>Orhan, Kaan</creator><creator>Kursun Çakmak, Emine Sebnem</creator><creator>Görürgöz, Cansu</creator><creator>Odabaşı, Onur</creator><creator>Yilmaz, Dervis</creator><creator>Atakan, Cemal</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-7771-048X</orcidid></search><sort><creationdate>20200801</creationdate><title>Evaluation of a metal artifact reduction algorithm and an optimization filter in the estimation of peri-implant dehiscence defects by using cone beam computed tomography: an in-vitro study</title><author>Bayrak, Seval ; Orhan, Kaan ; Kursun Çakmak, Emine Sebnem ; Görürgöz, Cansu ; Odabaşı, Onur ; Yilmaz, Dervis ; Atakan, Cemal</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c422t-58bc8db9582a8ddcd0ef590cce6bf9ab5fd06b74721830fce7348cc032995a5d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Dentistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bayrak, Seval</creatorcontrib><creatorcontrib>Orhan, Kaan</creatorcontrib><creatorcontrib>Kursun Çakmak, Emine Sebnem</creatorcontrib><creatorcontrib>Görürgöz, Cansu</creatorcontrib><creatorcontrib>Odabaşı, Onur</creatorcontrib><creatorcontrib>Yilmaz, Dervis</creatorcontrib><creatorcontrib>Atakan, Cemal</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Oral surgery, oral medicine, oral pathology and oral radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bayrak, Seval</au><au>Orhan, Kaan</au><au>Kursun Çakmak, Emine Sebnem</au><au>Görürgöz, Cansu</au><au>Odabaşı, Onur</au><au>Yilmaz, Dervis</au><au>Atakan, Cemal</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of a metal artifact reduction algorithm and an optimization filter in the estimation of peri-implant dehiscence defects by using cone beam computed tomography: an in-vitro study</atitle><jtitle>Oral surgery, oral medicine, oral pathology and oral radiology</jtitle><addtitle>Oral Surg Oral Med Oral Pathol Oral Radiol</addtitle><date>2020-08-01</date><risdate>2020</risdate><volume>130</volume><issue>2</issue><spage>209</spage><epage>216</epage><pages>209-216</pages><issn>2212-4403</issn><eissn>2212-4411</eissn><abstract>The aim of this study was to assess the effect of a metal artifact reduction (MAR) algorithm and the adaptive image noise optimizer (AINO) optimization filter in the detection of peri-implant dehiscences with cone beam computed tomography (CBCT). Nine implants (3 zirconium, 3 titanium, and 3 zirconium-titanium) were placed in 3 sheep heads. Dehiscences were created on the buccal and lingual/palatal surfaces. A total of 9 defects and 9 controls with no defects were evaluated by 3 observers. Each sheep head was scanned 5 times with 4 scan modes; (1) without MAR/without AINO; (2) with MAR/without AINO; (3) without MAR/with AINO; and (4) with MAR/with AINO. Receiver operating characteristic analysis and weighted kappa coefficients were used to calculate diagnostic efficacy and intra- and interobserver agreements for each implant type and scan mode. For all implant types, dehiscences were most accurately detected when both MAR and AINO were applied (P ≤ .045). Detection of dehiscences was more accurate with titanium implants (P ≤ .040). There were no significant differences in agreement among and between the observers. The use of both MAR and AINO enhanced the detection accuracy of artificially created dehiscences in proximity to implants. Their combined use is recommended for detecting peri-implant dehiscences.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>32197878</pmid><doi>10.1016/j.oooo.2020.02.005</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0001-7771-048X</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 2212-4403
ispartof Oral surgery, oral medicine, oral pathology and oral radiology, 2020-08, Vol.130 (2), p.209-216
issn 2212-4403
2212-4411
language eng
recordid cdi_proquest_miscellaneous_2381625315
source ScienceDirect Journals
subjects Dentistry
title Evaluation of a metal artifact reduction algorithm and an optimization filter in the estimation of peri-implant dehiscence defects by using cone beam computed tomography: an in-vitro study
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T15%3A17%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20a%20metal%20artifact%20reduction%20algorithm%20and%20an%20optimization%20filter%20in%20the%20estimation%20of%20peri-implant%20dehiscence%20defects%20by%20using%20cone%20beam%20computed%20tomography:%20an%20in-vitro%20study&rft.jtitle=Oral%20surgery,%20oral%20medicine,%20oral%20pathology%20and%20oral%20radiology&rft.au=Bayrak,%20Seval&rft.date=2020-08-01&rft.volume=130&rft.issue=2&rft.spage=209&rft.epage=216&rft.pages=209-216&rft.issn=2212-4403&rft.eissn=2212-4411&rft_id=info:doi/10.1016/j.oooo.2020.02.005&rft_dat=%3Cproquest_cross%3E2381625315%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c422t-58bc8db9582a8ddcd0ef590cce6bf9ab5fd06b74721830fce7348cc032995a5d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2381625315&rft_id=info:pmid/32197878&rfr_iscdi=true