Loading…
Wagner Cone Midterm Survivorship and Outcomes
Total hip arthroplasty (THA) in patients with abnormal proximal femoral anatomy requires an individualized treatment approach to prevent complications. Metaphyseal engaging stems in this population risk fracture, size/offset mismatch, and aseptic loosening. The Wagner conical femoral implant is a sh...
Saved in:
Published in: | The Journal of arthroplasty 2020-08, Vol.35 (8), p.2155-2160 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Total hip arthroplasty (THA) in patients with abnormal proximal femoral anatomy requires an individualized treatment approach to prevent complications. Metaphyseal engaging stems in this population risk fracture, size/offset mismatch, and aseptic loosening. The Wagner conical femoral implant is a short diaphyseal engaging femoral stem that could improve treatment success in this difficult patient population.
We identified 302 consecutive patients undergoing THA using the Wagner cone femoral prosthesis between January 2010 and January 2017. Clinical, radiographic, and patient-reported outcomes were obtained through chart review and radiographic measurements of postoperative X-rays. We used multivariate analysis to determine predictors of poor outcomes. Kaplan-Meier curves were created to demonstrate implant survivorship with reoperation and revision as endpoints. The average follow-up was 3.2 years, with a minimum of 2 years.
The implant retention survival rate during the 3.2-year study period was 98.7%. The overall reoperation rate was 4.2%, with infection followed by fracture being the most common reasons for reoperation. No patients were revised for aseptic loosening, and no patients were revised for subsidence. The average subsidence was 1.1 mm. The Harris Hip Score improved from 48.6 ± 7.3 (range, 28-64) preoperatively to 86.1 ± 8.5 (range, 66-100) at latest follow-up. The patient-reported satisfaction rate was 98.3%.
The Wagner cone femoral prosthesis demonstrated excellent clinical, radiographic, and patient-reported functional outcomes at midterm follow-up. We recommend use of the Wagner cone in THA patients with challenging proximal femoral anatomy, small femoral diameter, or poor metaphyseal bone quality. |
---|---|
ISSN: | 0883-5403 1532-8406 |
DOI: | 10.1016/j.arth.2020.03.015 |