Loading…

Down-scaling Sample Preparation Using Polyurethane Foam and Colorimetric Technique for the Chromium Assay in Accessories

A simple alternative colorimetric assay of chromium in accessories is proposed. A miniature part of a sample was dissolved by acid digestion. With dithiooxamide (DTO) complexes, metal interferences are retained in polyurethane foam synthesized in the lab, while chromium ions present in the eluate. A...

Full description

Saved in:
Bibliographic Details
Published in:Analytical Sciences 2020/09/10, Vol.36(9), pp.1137-1140
Main Authors: YEERUM, Chonnipa, AYUTTHAYA, Piyanat Issarangkura Na, KESONKAN, Kullapon, CHAIYAKHAN, Apidech, VONGBOOT, Monnapat
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A simple alternative colorimetric assay of chromium in accessories is proposed. A miniature part of a sample was dissolved by acid digestion. With dithiooxamide (DTO) complexes, metal interferences are retained in polyurethane foam synthesized in the lab, while chromium ions present in the eluate. A 100-μL volume of the eluate was measured for the absorbance using a handy spectrometer. The proposed method was successful for chromium assay and the results obtained agreed with the reference (FAAS) method. The amounts of chromium in accessories were found in the range of 100 to 390 mg g−1.
ISSN:0910-6340
1348-2246
DOI:10.2116/analsci.20N003