Loading…
Automatized follow-up and alert system for patients with chronic hypertension
This article presents the development and implementation of a monitoring system for patients with chronic hypertension. Technological advances in wireless communication are increasingly used today to send and receive information through smartphones. This also applies to devices for measuring blood p...
Saved in:
Published in: | Health informatics journal 2020-12, Vol.26 (4), p.2625-2636 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c407t-2bbb4768f94cf1018ef2e665f165b21ccf3eeeb3f9968c2bc0a4606a4e1518543 |
---|---|
cites | cdi_FETCH-LOGICAL-c407t-2bbb4768f94cf1018ef2e665f165b21ccf3eeeb3f9968c2bc0a4606a4e1518543 |
container_end_page | 2636 |
container_issue | 4 |
container_start_page | 2625 |
container_title | Health informatics journal |
container_volume | 26 |
creator | Urrea, Claudio Venegas, Daniel |
description | This article presents the development and implementation of a monitoring system for patients with chronic hypertension. Technological advances in wireless communication are increasingly used today to send and receive information through smartphones. This also applies to devices for measuring blood pressure, which can be efficiently integrated with smartphones. Telemedicine is used in a variety of health fields, and in the past 5 years, it has extended its reach to the online monitoring of patients. The objective of this study is to create an integrated system capable of conducting the follow-up, through mobile communication (smartphones), of patients with chronic diseases such as hypertension. An iHealth equipment certified by the Food and Drug Administration is used. The blood pressure values from users are uploaded via Internet and stored in an integral system for processing. The monitoring system developed not only informs users about their disease status but also sends them alerts generated during monitoring. This work uses the telecommunication technology existing through smartphones. The integrated system developed ensures the follow-up of the blood pressure of a large number of users. In addition, this system can be further applied to diseases such as diabetes and metabolic syndrome. The system developed was easy to use and efficient to monitor patients with chronic diseases such as high blood pressure. |
doi_str_mv | 10.1177/1460458219900446 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2395612471</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1460458219900446</sage_id><sourcerecordid>2470250968</sourcerecordid><originalsourceid>FETCH-LOGICAL-c407t-2bbb4768f94cf1018ef2e665f165b21ccf3eeeb3f9968c2bc0a4606a4e1518543</originalsourceid><addsrcrecordid>eNp1kM1Lw0AQxRdRbK3ePUnAi5fozu5mkxxL8QsqXvQcNttZm5Jk425CqX-9W1oVCp5m4P3mzcwj5BLoLUCa3oGQVCQZgzynVAh5RMaQCohZBnAc-iDHW31EzrxfUUo5TfgpGXHGeR7aMXmZDr1tVF994SIytq7tOh66SLWLSNXo-shvfI9NkFzUBQzb3kfrql9GeulsW-louekCh62vbHtOToyqPV7s64S8P9y_zZ7i-evj82w6j7WgaR-zsixFKjOTC22AQoaGoZSJAZmUDLQ2HBFLbvJcZpqVmqrwiVQCIYEsEXxCbna-nbOfA_q-aCqvsa5Vi3bwBeN5IoGJFAJ6fYCu7ODacF0RdMoSGnYEiu4o7az3Dk3RuapRblMALbZRF4dRh5GrvfFQNrj4HfjJNgDxDvDqA_-2_mv4Dcj0hXU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2470250968</pqid></control><display><type>article</type><title>Automatized follow-up and alert system for patients with chronic hypertension</title><source>Library & Information Science Abstracts (LISA)</source><source>SAGE Open Access</source><creator>Urrea, Claudio ; Venegas, Daniel</creator><creatorcontrib>Urrea, Claudio ; Venegas, Daniel</creatorcontrib><description>This article presents the development and implementation of a monitoring system for patients with chronic hypertension. Technological advances in wireless communication are increasingly used today to send and receive information through smartphones. This also applies to devices for measuring blood pressure, which can be efficiently integrated with smartphones. Telemedicine is used in a variety of health fields, and in the past 5 years, it has extended its reach to the online monitoring of patients. The objective of this study is to create an integrated system capable of conducting the follow-up, through mobile communication (smartphones), of patients with chronic diseases such as hypertension. An iHealth equipment certified by the Food and Drug Administration is used. The blood pressure values from users are uploaded via Internet and stored in an integral system for processing. The monitoring system developed not only informs users about their disease status but also sends them alerts generated during monitoring. This work uses the telecommunication technology existing through smartphones. The integrated system developed ensures the follow-up of the blood pressure of a large number of users. In addition, this system can be further applied to diseases such as diabetes and metabolic syndrome. The system developed was easy to use and efficient to monitor patients with chronic diseases such as high blood pressure.</description><identifier>ISSN: 1460-4582</identifier><identifier>EISSN: 1741-2811</identifier><identifier>DOI: 10.1177/1460458219900446</identifier><identifier>PMID: 32339053</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><subject>Blood pressure ; Chronic illnesses ; Hypertension ; Monitoring systems ; Smartphones ; Wireless communications</subject><ispartof>Health informatics journal, 2020-12, Vol.26 (4), p.2625-2636</ispartof><rights>The Author(s) 2020</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c407t-2bbb4768f94cf1018ef2e665f165b21ccf3eeeb3f9968c2bc0a4606a4e1518543</citedby><cites>FETCH-LOGICAL-c407t-2bbb4768f94cf1018ef2e665f165b21ccf3eeeb3f9968c2bc0a4606a4e1518543</cites><orcidid>0000-0001-7197-8928</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/1460458219900446$$EPDF$$P50$$Gsage$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/1460458219900446$$EHTML$$P50$$Gsage$$Hfree_for_read</linktohtml><link.rule.ids>314,776,780,21945,27830,27901,27902,34112,44921,45309</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32339053$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Urrea, Claudio</creatorcontrib><creatorcontrib>Venegas, Daniel</creatorcontrib><title>Automatized follow-up and alert system for patients with chronic hypertension</title><title>Health informatics journal</title><addtitle>Health Informatics J</addtitle><description>This article presents the development and implementation of a monitoring system for patients with chronic hypertension. Technological advances in wireless communication are increasingly used today to send and receive information through smartphones. This also applies to devices for measuring blood pressure, which can be efficiently integrated with smartphones. Telemedicine is used in a variety of health fields, and in the past 5 years, it has extended its reach to the online monitoring of patients. The objective of this study is to create an integrated system capable of conducting the follow-up, through mobile communication (smartphones), of patients with chronic diseases such as hypertension. An iHealth equipment certified by the Food and Drug Administration is used. The blood pressure values from users are uploaded via Internet and stored in an integral system for processing. The monitoring system developed not only informs users about their disease status but also sends them alerts generated during monitoring. This work uses the telecommunication technology existing through smartphones. The integrated system developed ensures the follow-up of the blood pressure of a large number of users. In addition, this system can be further applied to diseases such as diabetes and metabolic syndrome. The system developed was easy to use and efficient to monitor patients with chronic diseases such as high blood pressure.</description><subject>Blood pressure</subject><subject>Chronic illnesses</subject><subject>Hypertension</subject><subject>Monitoring systems</subject><subject>Smartphones</subject><subject>Wireless communications</subject><issn>1460-4582</issn><issn>1741-2811</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>AFRWT</sourceid><sourceid>F2A</sourceid><recordid>eNp1kM1Lw0AQxRdRbK3ePUnAi5fozu5mkxxL8QsqXvQcNttZm5Jk425CqX-9W1oVCp5m4P3mzcwj5BLoLUCa3oGQVCQZgzynVAh5RMaQCohZBnAc-iDHW31EzrxfUUo5TfgpGXHGeR7aMXmZDr1tVF994SIytq7tOh66SLWLSNXo-shvfI9NkFzUBQzb3kfrql9GeulsW-louekCh62vbHtOToyqPV7s64S8P9y_zZ7i-evj82w6j7WgaR-zsixFKjOTC22AQoaGoZSJAZmUDLQ2HBFLbvJcZpqVmqrwiVQCIYEsEXxCbna-nbOfA_q-aCqvsa5Vi3bwBeN5IoGJFAJ6fYCu7ODacF0RdMoSGnYEiu4o7az3Dk3RuapRblMALbZRF4dRh5GrvfFQNrj4HfjJNgDxDvDqA_-2_mv4Dcj0hXU</recordid><startdate>202012</startdate><enddate>202012</enddate><creator>Urrea, Claudio</creator><creator>Venegas, Daniel</creator><general>SAGE Publications</general><general>SAGE PUBLICATIONS, INC</general><scope>AFRWT</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>E3H</scope><scope>F2A</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-7197-8928</orcidid></search><sort><creationdate>202012</creationdate><title>Automatized follow-up and alert system for patients with chronic hypertension</title><author>Urrea, Claudio ; Venegas, Daniel</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c407t-2bbb4768f94cf1018ef2e665f165b21ccf3eeeb3f9968c2bc0a4606a4e1518543</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Blood pressure</topic><topic>Chronic illnesses</topic><topic>Hypertension</topic><topic>Monitoring systems</topic><topic>Smartphones</topic><topic>Wireless communications</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Urrea, Claudio</creatorcontrib><creatorcontrib>Venegas, Daniel</creatorcontrib><collection>SAGE Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Library & Information Sciences Abstracts (LISA)</collection><collection>Library & Information Science Abstracts (LISA)</collection><collection>MEDLINE - Academic</collection><jtitle>Health informatics journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Urrea, Claudio</au><au>Venegas, Daniel</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Automatized follow-up and alert system for patients with chronic hypertension</atitle><jtitle>Health informatics journal</jtitle><addtitle>Health Informatics J</addtitle><date>2020-12</date><risdate>2020</risdate><volume>26</volume><issue>4</issue><spage>2625</spage><epage>2636</epage><pages>2625-2636</pages><issn>1460-4582</issn><eissn>1741-2811</eissn><abstract>This article presents the development and implementation of a monitoring system for patients with chronic hypertension. Technological advances in wireless communication are increasingly used today to send and receive information through smartphones. This also applies to devices for measuring blood pressure, which can be efficiently integrated with smartphones. Telemedicine is used in a variety of health fields, and in the past 5 years, it has extended its reach to the online monitoring of patients. The objective of this study is to create an integrated system capable of conducting the follow-up, through mobile communication (smartphones), of patients with chronic diseases such as hypertension. An iHealth equipment certified by the Food and Drug Administration is used. The blood pressure values from users are uploaded via Internet and stored in an integral system for processing. The monitoring system developed not only informs users about their disease status but also sends them alerts generated during monitoring. This work uses the telecommunication technology existing through smartphones. The integrated system developed ensures the follow-up of the blood pressure of a large number of users. In addition, this system can be further applied to diseases such as diabetes and metabolic syndrome. The system developed was easy to use and efficient to monitor patients with chronic diseases such as high blood pressure.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><pmid>32339053</pmid><doi>10.1177/1460458219900446</doi><tpages>12</tpages><orcidid>https://orcid.org/0000-0001-7197-8928</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1460-4582 |
ispartof | Health informatics journal, 2020-12, Vol.26 (4), p.2625-2636 |
issn | 1460-4582 1741-2811 |
language | eng |
recordid | cdi_proquest_miscellaneous_2395612471 |
source | Library & Information Science Abstracts (LISA); SAGE Open Access |
subjects | Blood pressure Chronic illnesses Hypertension Monitoring systems Smartphones Wireless communications |
title | Automatized follow-up and alert system for patients with chronic hypertension |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-29T12%3A29%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Automatized%20follow-up%20and%20alert%20system%20for%20patients%20with%20chronic%20hypertension&rft.jtitle=Health%20informatics%20journal&rft.au=Urrea,%20Claudio&rft.date=2020-12&rft.volume=26&rft.issue=4&rft.spage=2625&rft.epage=2636&rft.pages=2625-2636&rft.issn=1460-4582&rft.eissn=1741-2811&rft_id=info:doi/10.1177/1460458219900446&rft_dat=%3Cproquest_cross%3E2470250968%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c407t-2bbb4768f94cf1018ef2e665f165b21ccf3eeeb3f9968c2bc0a4606a4e1518543%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2470250968&rft_id=info:pmid/32339053&rft_sage_id=10.1177_1460458219900446&rfr_iscdi=true |