Root fillings with a matched-taper single cone and two calcium silicate–based sealers: an analysis of voids using micro-computed tomography
Objectives To compare the percentage of voids in matched-taper single-cone fillings with GuttaFlow Bioseal or BioRoot RCS root canal sealers, using micro-computed tomography. Materials and methods Forty-eight single-rooted mandibular premolars were prepared using rotary files and randomly allocated...
Saved in:
Published in: | Clinical oral investigations 2020-12, Vol.24 (12), p.4487-4492 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Objectives
To compare the percentage of voids in matched-taper single-cone fillings with GuttaFlow Bioseal or BioRoot RCS root canal sealers, using micro-computed tomography.
Materials and methods
Forty-eight single-rooted mandibular premolars were prepared using rotary files and randomly allocated into 2 groups (
n
= 24), wherein the canals were filled with a matched-taper single gutta-percha cone and one of the two sealers: Group 1, GuttaFlow Bioseal and Group 2, BioRoot RCS. The specimens were scanned with micro-CT before and after root canal filling. A specialized software was used to calculate the voids volume percentage (V%) in the filling for the whole root canal, root canal thirds, and the last millimeter from the apex. Data were statistically analyzed by ANOVA and Tukey tests (
p
0.05), while BioRoot RCS group had significantly greater V% in the coronal third compared with the other thirds (
p
|
---|---|
ISSN: | 1432-6981 1436-3771 |