Treatment of left‐sided extension of AV node: A valuable integration of advance imaging modalities and cryoablation

We present a case of successful cryoablation of the left extension of the atrioventricular (AV) node for treatment of a recurrent atrioventricular nodal reentry tachycardia without the use of fluoroscopy. Three‐dimensional electroanatomic mapping system and intracardiac echocardiography were used to...

Full description

Saved in:
Bibliographic Details
Published in:Pacing and clinical electrophysiology 2020-12, Vol.43 (12), p.1605-1608
Main Authors: Prolic Kalinsek, Tine, Pernat, Andrej, Sinkovec, Matjaz, Jan, Matevz
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c3575-26baaa407e8efaf8d15be6f8630a3e28712f01da4576c8a0003a0ca7a31a84a13
cites cdi_FETCH-LOGICAL-c3575-26baaa407e8efaf8d15be6f8630a3e28712f01da4576c8a0003a0ca7a31a84a13
container_end_page 1608
container_issue 12
container_start_page 1605
container_title Pacing and clinical electrophysiology
container_volume 43
creator Prolic Kalinsek, Tine
Pernat, Andrej
Sinkovec, Matjaz
Jan, Matevz
description We present a case of successful cryoablation of the left extension of the atrioventricular (AV) node for treatment of a recurrent atrioventricular nodal reentry tachycardia without the use of fluoroscopy. Three‐dimensional electroanatomic mapping system and intracardiac echocardiography were used to navigate catheters in the heart and position them according to anatomical landmarks. Due to the nature of cryoablation lesion formation, lesions were able to be applied safely in right atrium, as well as in left atrium, without damaging AV node or bundle of His.
doi_str_mv 10.1111/pace.14015
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2424994640</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2424994640</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3575-26baaa407e8efaf8d15be6f8630a3e28712f01da4576c8a0003a0ca7a31a84a13</originalsourceid><addsrcrecordid>eNp90b1OwzAQB3ALgaB8LDwAssSCkAJ2YicOW1XxJVWCobBG1_hSBSV2sROgG4_AM_IkuLQwMODFkv3zX3c-Qg45O-Nhnc-hxDMuGJcbZMClYJHiMt8kA8ZFFqlE5Ttk1_snxljKhNwmO0mcBhKLAeknDqFr0XTUVrTBqvt8__C1Rk3xrUPja2uWN8NHaqzGCzqkL9D0MG2Q1qbDmYNuTUC_gCnDcQuz2sxoazU0dVejp2A0Ld3ChmfffJ9sVdB4PFjve-Th6nIyuonGd9e3o-E4KhOZyShOpwAgWIYKK6iU5nKKaaXShEGCscp4XDGuQcgsLRWE_hJgJWSQcFACeLJHTla5c2efe_Rd0da-xKYBg7b3RSxikeciFSzQ4z_0yfbOhOqCyhhPWSzzoE5XqnTWe4dVMXehX7coOCuWwyiWwyi-hxHw0Tqyn7aof-nP7wfAV-C1bnDxT1RxPxxdrkK_ADoQlW0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2470160259</pqid></control><display><type>article</type><title>Treatment of left‐sided extension of AV node: A valuable integration of advance imaging modalities and cryoablation</title><source>Wiley</source><source>SPORTDiscus with Full Text</source><creator>Prolic Kalinsek, Tine ; Pernat, Andrej ; Sinkovec, Matjaz ; Jan, Matevz</creator><creatorcontrib>Prolic Kalinsek, Tine ; Pernat, Andrej ; Sinkovec, Matjaz ; Jan, Matevz</creatorcontrib><description>We present a case of successful cryoablation of the left extension of the atrioventricular (AV) node for treatment of a recurrent atrioventricular nodal reentry tachycardia without the use of fluoroscopy. Three‐dimensional electroanatomic mapping system and intracardiac echocardiography were used to navigate catheters in the heart and position them according to anatomical landmarks. Due to the nature of cryoablation lesion formation, lesions were able to be applied safely in right atrium, as well as in left atrium, without damaging AV node or bundle of His.</description><identifier>ISSN: 0147-8389</identifier><identifier>EISSN: 1540-8159</identifier><identifier>DOI: 10.1111/pace.14015</identifier><identifier>PMID: 32681524</identifier><language>eng</language><publisher>United States: Wiley Subscription Services, Inc</publisher><subject>atrioventricular nodal reentry tachycardia ; Atrium ; Catheters ; cryoablation ; Echocardiography ; Fluoroscopy ; intracardiac echocardiography ; left‐sided extension of atrioventricular node ; Tachycardia ; three‐dimensional electroanatomic mapping system</subject><ispartof>Pacing and clinical electrophysiology, 2020-12, Vol.43 (12), p.1605-1608</ispartof><rights>2020 Wiley Periodicals LLC</rights><rights>2020 Wiley Periodicals LLC.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3575-26baaa407e8efaf8d15be6f8630a3e28712f01da4576c8a0003a0ca7a31a84a13</citedby><cites>FETCH-LOGICAL-c3575-26baaa407e8efaf8d15be6f8630a3e28712f01da4576c8a0003a0ca7a31a84a13</cites><orcidid>0000-0001-6765-1527</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32681524$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Prolic Kalinsek, Tine</creatorcontrib><creatorcontrib>Pernat, Andrej</creatorcontrib><creatorcontrib>Sinkovec, Matjaz</creatorcontrib><creatorcontrib>Jan, Matevz</creatorcontrib><title>Treatment of left‐sided extension of AV node: A valuable integration of advance imaging modalities and cryoablation</title><title>Pacing and clinical electrophysiology</title><addtitle>Pacing Clin Electrophysiol</addtitle><description>We present a case of successful cryoablation of the left extension of the atrioventricular (AV) node for treatment of a recurrent atrioventricular nodal reentry tachycardia without the use of fluoroscopy. Three‐dimensional electroanatomic mapping system and intracardiac echocardiography were used to navigate catheters in the heart and position them according to anatomical landmarks. Due to the nature of cryoablation lesion formation, lesions were able to be applied safely in right atrium, as well as in left atrium, without damaging AV node or bundle of His.</description><subject>atrioventricular nodal reentry tachycardia</subject><subject>Atrium</subject><subject>Catheters</subject><subject>cryoablation</subject><subject>Echocardiography</subject><subject>Fluoroscopy</subject><subject>intracardiac echocardiography</subject><subject>left‐sided extension of atrioventricular node</subject><subject>Tachycardia</subject><subject>three‐dimensional electroanatomic mapping system</subject><issn>0147-8389</issn><issn>1540-8159</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp90b1OwzAQB3ALgaB8LDwAssSCkAJ2YicOW1XxJVWCobBG1_hSBSV2sROgG4_AM_IkuLQwMODFkv3zX3c-Qg45O-Nhnc-hxDMuGJcbZMClYJHiMt8kA8ZFFqlE5Ttk1_snxljKhNwmO0mcBhKLAeknDqFr0XTUVrTBqvt8__C1Rk3xrUPja2uWN8NHaqzGCzqkL9D0MG2Q1qbDmYNuTUC_gCnDcQuz2sxoazU0dVejp2A0Ld3ChmfffJ9sVdB4PFjve-Th6nIyuonGd9e3o-E4KhOZyShOpwAgWIYKK6iU5nKKaaXShEGCscp4XDGuQcgsLRWE_hJgJWSQcFACeLJHTla5c2efe_Rd0da-xKYBg7b3RSxikeciFSzQ4z_0yfbOhOqCyhhPWSzzoE5XqnTWe4dVMXehX7coOCuWwyiWwyi-hxHw0Tqyn7aof-nP7wfAV-C1bnDxT1RxPxxdrkK_ADoQlW0</recordid><startdate>202012</startdate><enddate>202012</enddate><creator>Prolic Kalinsek, Tine</creator><creator>Pernat, Andrej</creator><creator>Sinkovec, Matjaz</creator><creator>Jan, Matevz</creator><general>Wiley Subscription Services, Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TK</scope><scope>NAPCQ</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-6765-1527</orcidid></search><sort><creationdate>202012</creationdate><title>Treatment of left‐sided extension of AV node: A valuable integration of advance imaging modalities and cryoablation</title><author>Prolic Kalinsek, Tine ; Pernat, Andrej ; Sinkovec, Matjaz ; Jan, Matevz</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3575-26baaa407e8efaf8d15be6f8630a3e28712f01da4576c8a0003a0ca7a31a84a13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>atrioventricular nodal reentry tachycardia</topic><topic>Atrium</topic><topic>Catheters</topic><topic>cryoablation</topic><topic>Echocardiography</topic><topic>Fluoroscopy</topic><topic>intracardiac echocardiography</topic><topic>left‐sided extension of atrioventricular node</topic><topic>Tachycardia</topic><topic>three‐dimensional electroanatomic mapping system</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Prolic Kalinsek, Tine</creatorcontrib><creatorcontrib>Pernat, Andrej</creatorcontrib><creatorcontrib>Sinkovec, Matjaz</creatorcontrib><creatorcontrib>Jan, Matevz</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Neurosciences Abstracts</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>MEDLINE - Academic</collection><jtitle>Pacing and clinical electrophysiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Prolic Kalinsek, Tine</au><au>Pernat, Andrej</au><au>Sinkovec, Matjaz</au><au>Jan, Matevz</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Treatment of left‐sided extension of AV node: A valuable integration of advance imaging modalities and cryoablation</atitle><jtitle>Pacing and clinical electrophysiology</jtitle><addtitle>Pacing Clin Electrophysiol</addtitle><date>2020-12</date><risdate>2020</risdate><volume>43</volume><issue>12</issue><spage>1605</spage><epage>1608</epage><pages>1605-1608</pages><issn>0147-8389</issn><eissn>1540-8159</eissn><abstract>We present a case of successful cryoablation of the left extension of the atrioventricular (AV) node for treatment of a recurrent atrioventricular nodal reentry tachycardia without the use of fluoroscopy. Three‐dimensional electroanatomic mapping system and intracardiac echocardiography were used to navigate catheters in the heart and position them according to anatomical landmarks. Due to the nature of cryoablation lesion formation, lesions were able to be applied safely in right atrium, as well as in left atrium, without damaging AV node or bundle of His.</abstract><cop>United States</cop><pub>Wiley Subscription Services, Inc</pub><pmid>32681524</pmid><doi>10.1111/pace.14015</doi><tpages>4</tpages><orcidid>https://orcid.org/0000-0001-6765-1527</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0147-8389
ispartof Pacing and clinical electrophysiology, 2020-12, Vol.43 (12), p.1605-1608
issn 0147-8389
1540-8159
language eng
recordid cdi_proquest_miscellaneous_2424994640
source Wiley; SPORTDiscus with Full Text
subjects atrioventricular nodal reentry tachycardia
Atrium
Catheters
cryoablation
Echocardiography
Fluoroscopy
intracardiac echocardiography
left‐sided extension of atrioventricular node
Tachycardia
three‐dimensional electroanatomic mapping system
title Treatment of left‐sided extension of AV node: A valuable integration of advance imaging modalities and cryoablation
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T20%3A58%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Treatment%20of%20left%E2%80%90sided%20extension%20of%20AV%20node:%20A%20valuable%20integration%20of%20advance%20imaging%20modalities%20and%20cryoablation&rft.jtitle=Pacing%20and%20clinical%20electrophysiology&rft.au=Prolic%20Kalinsek,%20Tine&rft.date=2020-12&rft.volume=43&rft.issue=12&rft.spage=1605&rft.epage=1608&rft.pages=1605-1608&rft.issn=0147-8389&rft.eissn=1540-8159&rft_id=info:doi/10.1111/pace.14015&rft_dat=%3Cproquest_cross%3E2424994640%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3575-26baaa407e8efaf8d15be6f8630a3e28712f01da4576c8a0003a0ca7a31a84a13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2470160259&rft_id=info:pmid/32681524&rfr_iscdi=true