Loading…

The Hip Suction Seal, Part I: The Role of Acetabular Labral Height on Hip Distractive Stability

Background: The acetabular labrum has been found to provide a significant contribution to the distractive stability of the hip. However, the influence of labral height on hip suction seal biomechanics is not known. Hypothesis: The smaller height of acetabular labrum is associated with decreased dist...

Full description

Saved in:
Bibliographic Details
Published in:The American journal of sports medicine 2020-09, Vol.48 (11), p.2726-2732
Main Authors: Storaci, Hunter W., Utsunomiya, Hajime, Kemler, Bryson R., Rosenberg, Samuel I., Dornan, Grant J., Brady, Alex W., Philippon, Marc J.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background: The acetabular labrum has been found to provide a significant contribution to the distractive stability of the hip. However, the influence of labral height on hip suction seal biomechanics is not known. Hypothesis: The smaller height of acetabular labrum is associated with decreased distractive stability. Study Design: Descriptive laboratory study. Methods: A total of 23 fresh-frozen cadaveric hemipelvises were used in this study. Hips with acetabular dysplasia or femoroacetabular impingement–related bony morphologic features, intra-articular pathology, or no measurable suction seal were excluded. Before testing, each specimen’s hip capsule was removed, a pressure sensor was placed intra-articularly, and the hip was fixed in a heated saline bath. Labral size was measured by use of a digital caliper. Maximum distraction force, distance to suction seal rupture, and peak negative pressure were recorded while the hip underwent distraction at a rate of 0.5 mm/s. Correlations between factors were analyzed using the Spearman rho, and differences between groups were detected using Mann-Whitney U test. Results: Of 23 hips, 12 satisfied inclusion criteria. The maximum distraction force and peak negative pressure were significantly correlated (R = −0.83; P = .001). Labral height was largely correlated with all suction seal parameters (maximum distraction force, R = 0.69, P = .013; distance to suction seal rupture, R = 0.55, P = .063; peak negative pressure, R = −0.62, P = .031). Labral height less than 6 mm was observed in 5 hips, with a mean height of 6.48 mm (SD, 2.65 mm; range, 2.62-11.90 mm; 95% CI, 4.80-8.17 mm). Compared with the 7 hips with larger labra (>6 mm), the hips with smaller labra had significantly shorter distance to suction seal rupture (median, 2.3 vs 7.2 mm; P = .010) and significantly decreased peak negative pressure (median, −59.3 vs −66.9 kPa; P = .048). Conclusion: Smaller height (
ISSN:0363-5465
1552-3365
DOI:10.1177/0363546520941855