Loading…
The Hip Suction Seal, Part I: The Role of Acetabular Labral Height on Hip Distractive Stability
Background: The acetabular labrum has been found to provide a significant contribution to the distractive stability of the hip. However, the influence of labral height on hip suction seal biomechanics is not known. Hypothesis: The smaller height of acetabular labrum is associated with decreased dist...
Saved in:
Published in: | The American journal of sports medicine 2020-09, Vol.48 (11), p.2726-2732 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Background:
The acetabular labrum has been found to provide a significant contribution to the distractive stability of the hip. However, the influence of labral height on hip suction seal biomechanics is not known.
Hypothesis:
The smaller height of acetabular labrum is associated with decreased distractive stability.
Study Design:
Descriptive laboratory study.
Methods:
A total of 23 fresh-frozen cadaveric hemipelvises were used in this study. Hips with acetabular dysplasia or femoroacetabular impingement–related bony morphologic features, intra-articular pathology, or no measurable suction seal were excluded. Before testing, each specimen’s hip capsule was removed, a pressure sensor was placed intra-articularly, and the hip was fixed in a heated saline bath. Labral size was measured by use of a digital caliper. Maximum distraction force, distance to suction seal rupture, and peak negative pressure were recorded while the hip underwent distraction at a rate of 0.5 mm/s. Correlations between factors were analyzed using the Spearman rho, and differences between groups were detected using Mann-Whitney U test.
Results:
Of 23 hips, 12 satisfied inclusion criteria. The maximum distraction force and peak negative pressure were significantly correlated (R = −0.83; P = .001). Labral height was largely correlated with all suction seal parameters (maximum distraction force, R = 0.69, P = .013; distance to suction seal rupture, R = 0.55, P = .063; peak negative pressure, R = −0.62, P = .031). Labral height less than 6 mm was observed in 5 hips, with a mean height of 6.48 mm (SD, 2.65 mm; range, 2.62-11.90 mm; 95% CI, 4.80-8.17 mm). Compared with the 7 hips with larger labra (>6 mm), the hips with smaller labra had significantly shorter distance to suction seal rupture (median, 2.3 vs 7.2 mm; P = .010) and significantly decreased peak negative pressure (median, −59.3 vs −66.9 kPa; P = .048).
Conclusion:
Smaller height ( |
---|---|
ISSN: | 0363-5465 1552-3365 |
DOI: | 10.1177/0363546520941855 |