Loading…

10B Conformal Doping for Highly Efficient Thermal Neutron Detectors

This paper reports a simple and novel conformal doping strategy for microstructured silicon diodes using enriched 10B for sidewall doping while enabling enhanced neutron sensitivity. Monte-Carlo nuclear particle (MCNP) code simulations were initially used to calculate the neutron detection efficienc...

Full description

Saved in:
Bibliographic Details
Published in:ACS sensors 2020-09, Vol.5 (9), p.2852-2857
Main Authors: Nandagopala Krishnan, Siddartha S, Avila-Avendano, Carlos, Shamsi, Zeshaan, Caraveo-Frescas, Jesus A, Quevedo-Lopez, Manuel A
Format: Article
Language:English
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 2857
container_issue 9
container_start_page 2852
container_title ACS sensors
container_volume 5
creator Nandagopala Krishnan, Siddartha S
Avila-Avendano, Carlos
Shamsi, Zeshaan
Caraveo-Frescas, Jesus A
Quevedo-Lopez, Manuel A
description This paper reports a simple and novel conformal doping strategy for microstructured silicon diodes using enriched 10B for sidewall doping while enabling enhanced neutron sensitivity. Monte-Carlo nuclear particle (MCNP) code simulations were initially used to calculate the neutron detection efficiency in the microstructured diodes as a function of geometry and pitch. A high-temperature anneal in 10B-filled diodes results in a conformal silicon p+ layer along the side walls of the trenches in the diodes. This results in large neutron detection areas and enhanced neutron detection efficiency when compared with planar detectors. With the method discussed here, a thermal neutron detection of ∼21% efficiency is achieved, which is significantly higher than the efficiency achieved in planar detectors (∼3.5%). The higher efficiency is enabled by the 10B acting as a source for conformal doping in the trenches, resulting in lower leakage current while also enabling neutron sensitivity in the microstructured diodes.
doi_str_mv 10.1021/acssensors.0c01013
format article
fullrecord <record><control><sourceid>proquest_acs_j</sourceid><recordid>TN_cdi_proquest_miscellaneous_2434054288</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2434054288</sourcerecordid><originalsourceid>FETCH-LOGICAL-a728-a74cda990afa4001dbe97abefca1791a342b7073d0611fd13b18ec8cbd95cf753</originalsourceid><addsrcrecordid>eNpNkD1PwzAQhi0EElXpH2DyyNJyZzt1PEJaKFIFS3bLcew2VWqXOBn49wRaCZb7kB7dvXoIuUdYIDB8NDYlF1Ls0gIsICC_IhPGpZrzpRLX_-ZbMkvpAACYLVmWw4QUCM-0iMHH7mhauoqnJuzouNFNs9u3X3TtfWMbF3pa7t0v8-6GvouBrlzvbD9-vSM33rTJzS59SsqXdVls5tuP17fiaTs3kuVjEbY2SoHxRowJ6sopaSrnrUGp0HDBKgmS17BE9DXyCnNnc1vVKrNeZnxKHs5nT138HFzq9bFJ1rWtCS4OSTPBBWSC5fmILs7oqEYf4tCFMZdG0D--9J8vffHFvwE2R2CV</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2434054288</pqid></control><display><type>article</type><title>10B Conformal Doping for Highly Efficient Thermal Neutron Detectors</title><source>American Chemical Society:Jisc Collections:American Chemical Society Read &amp; Publish Agreement 2022-2024 (Reading list)</source><creator>Nandagopala Krishnan, Siddartha S ; Avila-Avendano, Carlos ; Shamsi, Zeshaan ; Caraveo-Frescas, Jesus A ; Quevedo-Lopez, Manuel A</creator><creatorcontrib>Nandagopala Krishnan, Siddartha S ; Avila-Avendano, Carlos ; Shamsi, Zeshaan ; Caraveo-Frescas, Jesus A ; Quevedo-Lopez, Manuel A</creatorcontrib><description>This paper reports a simple and novel conformal doping strategy for microstructured silicon diodes using enriched 10B for sidewall doping while enabling enhanced neutron sensitivity. Monte-Carlo nuclear particle (MCNP) code simulations were initially used to calculate the neutron detection efficiency in the microstructured diodes as a function of geometry and pitch. A high-temperature anneal in 10B-filled diodes results in a conformal silicon p+ layer along the side walls of the trenches in the diodes. This results in large neutron detection areas and enhanced neutron detection efficiency when compared with planar detectors. With the method discussed here, a thermal neutron detection of ∼21% efficiency is achieved, which is significantly higher than the efficiency achieved in planar detectors (∼3.5%). The higher efficiency is enabled by the 10B acting as a source for conformal doping in the trenches, resulting in lower leakage current while also enabling neutron sensitivity in the microstructured diodes.</description><identifier>ISSN: 2379-3694</identifier><identifier>EISSN: 2379-3694</identifier><identifier>DOI: 10.1021/acssensors.0c01013</identifier><language>eng</language><publisher>American Chemical Society</publisher><ispartof>ACS sensors, 2020-09, Vol.5 (9), p.2852-2857</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><orcidid>0000-0002-6742-951X ; 0000-0002-1867-7584 ; 0000-0002-5386-7762</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Nandagopala Krishnan, Siddartha S</creatorcontrib><creatorcontrib>Avila-Avendano, Carlos</creatorcontrib><creatorcontrib>Shamsi, Zeshaan</creatorcontrib><creatorcontrib>Caraveo-Frescas, Jesus A</creatorcontrib><creatorcontrib>Quevedo-Lopez, Manuel A</creatorcontrib><title>10B Conformal Doping for Highly Efficient Thermal Neutron Detectors</title><title>ACS sensors</title><addtitle>ACS Sens</addtitle><description>This paper reports a simple and novel conformal doping strategy for microstructured silicon diodes using enriched 10B for sidewall doping while enabling enhanced neutron sensitivity. Monte-Carlo nuclear particle (MCNP) code simulations were initially used to calculate the neutron detection efficiency in the microstructured diodes as a function of geometry and pitch. A high-temperature anneal in 10B-filled diodes results in a conformal silicon p+ layer along the side walls of the trenches in the diodes. This results in large neutron detection areas and enhanced neutron detection efficiency when compared with planar detectors. With the method discussed here, a thermal neutron detection of ∼21% efficiency is achieved, which is significantly higher than the efficiency achieved in planar detectors (∼3.5%). The higher efficiency is enabled by the 10B acting as a source for conformal doping in the trenches, resulting in lower leakage current while also enabling neutron sensitivity in the microstructured diodes.</description><issn>2379-3694</issn><issn>2379-3694</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNpNkD1PwzAQhi0EElXpH2DyyNJyZzt1PEJaKFIFS3bLcew2VWqXOBn49wRaCZb7kB7dvXoIuUdYIDB8NDYlF1Ls0gIsICC_IhPGpZrzpRLX_-ZbMkvpAACYLVmWw4QUCM-0iMHH7mhauoqnJuzouNFNs9u3X3TtfWMbF3pa7t0v8-6GvouBrlzvbD9-vSM33rTJzS59SsqXdVls5tuP17fiaTs3kuVjEbY2SoHxRowJ6sopaSrnrUGp0HDBKgmS17BE9DXyCnNnc1vVKrNeZnxKHs5nT138HFzq9bFJ1rWtCS4OSTPBBWSC5fmILs7oqEYf4tCFMZdG0D--9J8vffHFvwE2R2CV</recordid><startdate>20200925</startdate><enddate>20200925</enddate><creator>Nandagopala Krishnan, Siddartha S</creator><creator>Avila-Avendano, Carlos</creator><creator>Shamsi, Zeshaan</creator><creator>Caraveo-Frescas, Jesus A</creator><creator>Quevedo-Lopez, Manuel A</creator><general>American Chemical Society</general><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-6742-951X</orcidid><orcidid>https://orcid.org/0000-0002-1867-7584</orcidid><orcidid>https://orcid.org/0000-0002-5386-7762</orcidid></search><sort><creationdate>20200925</creationdate><title>10B Conformal Doping for Highly Efficient Thermal Neutron Detectors</title><author>Nandagopala Krishnan, Siddartha S ; Avila-Avendano, Carlos ; Shamsi, Zeshaan ; Caraveo-Frescas, Jesus A ; Quevedo-Lopez, Manuel A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a728-a74cda990afa4001dbe97abefca1791a342b7073d0611fd13b18ec8cbd95cf753</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nandagopala Krishnan, Siddartha S</creatorcontrib><creatorcontrib>Avila-Avendano, Carlos</creatorcontrib><creatorcontrib>Shamsi, Zeshaan</creatorcontrib><creatorcontrib>Caraveo-Frescas, Jesus A</creatorcontrib><creatorcontrib>Quevedo-Lopez, Manuel A</creatorcontrib><collection>MEDLINE - Academic</collection><jtitle>ACS sensors</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nandagopala Krishnan, Siddartha S</au><au>Avila-Avendano, Carlos</au><au>Shamsi, Zeshaan</au><au>Caraveo-Frescas, Jesus A</au><au>Quevedo-Lopez, Manuel A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>10B Conformal Doping for Highly Efficient Thermal Neutron Detectors</atitle><jtitle>ACS sensors</jtitle><addtitle>ACS Sens</addtitle><date>2020-09-25</date><risdate>2020</risdate><volume>5</volume><issue>9</issue><spage>2852</spage><epage>2857</epage><pages>2852-2857</pages><issn>2379-3694</issn><eissn>2379-3694</eissn><abstract>This paper reports a simple and novel conformal doping strategy for microstructured silicon diodes using enriched 10B for sidewall doping while enabling enhanced neutron sensitivity. Monte-Carlo nuclear particle (MCNP) code simulations were initially used to calculate the neutron detection efficiency in the microstructured diodes as a function of geometry and pitch. A high-temperature anneal in 10B-filled diodes results in a conformal silicon p+ layer along the side walls of the trenches in the diodes. This results in large neutron detection areas and enhanced neutron detection efficiency when compared with planar detectors. With the method discussed here, a thermal neutron detection of ∼21% efficiency is achieved, which is significantly higher than the efficiency achieved in planar detectors (∼3.5%). The higher efficiency is enabled by the 10B acting as a source for conformal doping in the trenches, resulting in lower leakage current while also enabling neutron sensitivity in the microstructured diodes.</abstract><pub>American Chemical Society</pub><doi>10.1021/acssensors.0c01013</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0002-6742-951X</orcidid><orcidid>https://orcid.org/0000-0002-1867-7584</orcidid><orcidid>https://orcid.org/0000-0002-5386-7762</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 2379-3694
ispartof ACS sensors, 2020-09, Vol.5 (9), p.2852-2857
issn 2379-3694
2379-3694
language eng
recordid cdi_proquest_miscellaneous_2434054288
source American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list)
title 10B Conformal Doping for Highly Efficient Thermal Neutron Detectors
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T05%3A54%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_acs_j&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=10B%20Conformal%20Doping%20for%20Highly%20Efficient%20Thermal%20Neutron%20Detectors&rft.jtitle=ACS%20sensors&rft.au=Nandagopala%20Krishnan,%20Siddartha%20S&rft.date=2020-09-25&rft.volume=5&rft.issue=9&rft.spage=2852&rft.epage=2857&rft.pages=2852-2857&rft.issn=2379-3694&rft.eissn=2379-3694&rft_id=info:doi/10.1021/acssensors.0c01013&rft_dat=%3Cproquest_acs_j%3E2434054288%3C/proquest_acs_j%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a728-a74cda990afa4001dbe97abefca1791a342b7073d0611fd13b18ec8cbd95cf753%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2434054288&rft_id=info:pmid/&rfr_iscdi=true