Loading…
Cyclic voltammetric study of copper electrode pretreatment for metal migration and corrosion rates
Lithographic techniques for microcircuitry leave photoresist materials on Cu surfaces which must be removed to obtain reproducible metal migration rates. Reproducible results are obtained after these cleaning steps: (i) 25% HNO sub 3 (30 deg C), (ii) water rinse, (iii) 25% HCl (30 deg C), (iv) water...
Saved in:
Published in: | Journal of the Electrochemical Society 1987-08, Vol.134 (8), p.1902-1905 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Lithographic techniques for microcircuitry leave photoresist materials on Cu surfaces which must be removed to obtain reproducible metal migration rates. Reproducible results are obtained after these cleaning steps: (i) 25% HNO sub 3 (30 deg C), (ii) water rinse, (iii) 25% HCl (30 deg C), (iv) water then isopropanol rinse and storage. Rapid, blank, electrical-short-times are found using the first two steps and long, blank-times for all steps. Cyclic voltammetry at high purity Cu electrodes over the range of --0.1 to --1.0 V vs. Ag/AgCl correlates cleaning procedure with the presence or absence of surface oxides and/or Cu ions. Good agreement was found between blank, accelerated test runs for metal migration devices and CV scans. A precise and reproducible method of characterizing the conditions of a metal surface after mechanical, chemical, and/or environmental treatment is provided by CV scans. 7 ref.--AA |
---|---|
ISSN: | 0013-4651 1945-7111 |
DOI: | 10.1149/1.2100786 |