The central blood volume as measured by thoracic electrical impedance and plasma proANP is not compromised by donation of 900 mL of blood in men

Objectives To evaluate whether the donation of 900 mL of blood reduces the central blood volume (CBV) assessed by thoracic electrical impedance (TI) and plasma pro‐atrial natriuretic peptide (proANP). Background Donation of 450 mL of blood carries a 1% risk of a vasovagal reaction. Withdrawal of 900...

Full description

Saved in:
Bibliographic Details
Published in:Transfusion medicine (Oxford, England) England), 2020-12, Vol.30 (6), p.450-455
Main Authors: Gybel‐Brask, Mikkel, Nordsborg, Nikolai Baastrup, Goetze, Jens P., Johansson, Pär I., Secher, Niels H., Bejder, Jacob
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Objectives To evaluate whether the donation of 900 mL of blood reduces the central blood volume (CBV) assessed by thoracic electrical impedance (TI) and plasma pro‐atrial natriuretic peptide (proANP). Background Donation of 450 mL of blood carries a 1% risk of a vasovagal reaction. Withdrawal of 900 mL of blood decreases cardiac output; however, the effect on CBV remains unknown. Methods/Materials A randomised, single‐blinded, placebo‐controlled, crossover design was used, where 21 healthy semi‐recumbent men donated 2 × 450 mL blood or were sham‐phlebotomised. Changes in CBV were estimated by proANP and TI at 1.5 (TI1.5) and 100 (TI100) kHz, reflecting extracellular volume and (regional) total body water, respectively, and the index value (IDX; 1/T1.5‐1/TI100) was used to estimate changes in intracellular (red cell) volume. Systolic, diastolic and mean arterial blood pressure; heart rate; stroke volume; cardiac output; and systemic vascular resistance were monitored. After completion of the study, 1000 mL of isotonic saline was infused. Results Changes (mean% ± SD) in TI1.5, TI100 and IDX were similar after 450 mL (−0.2 ± 1.6%, 0.0 ± 1.1%, −0.4 ± 10.1%) and 900 mL (0.1 ± 1.6%, 0.2 ± 1.5% and −2.0 ± 15.8%) of blood donation compared to after a sham donation of 450 mL (−0.9 ± 1.2%, −0.5 ± 1.5% and −0.1 ± 6.1%) and 900 mL (−1.2 ± 1.5%, −0.6 ± 1.3% and 0.5 ± 9.9%). In addition, changes in plasma proANP were similar after 450 and 900 mL of blood donation (−0.8 ± 6.7% and −7.6 ± 7.9%) as after sham donations (1.3 ± 7.3% and −4.5 ± 5.6%). Monitoring haemodynamic variables revealed that stroke volume decreased after the donation of 900 mL of blood (−12 ± 12 mL) compared to sham donations. Conclusion During a 900‐mL blood loss in semi‐recumbent men, CBV measured by TI and plasma proANP is not affected.
ISSN:0958-7578
1365-3148